CA6LS
Cable Connector. 6 pin male connection...
Cable Gland Fitted
System integrated cable gland fitted to a purchased enclosure by our technicians...
CDI 25
CDI 25 Compressed Air Flow Meter for local display with alarm functions. Suitable for compressed air and Nitrogen. Unit comes with two band clamps, 4 digit LED digital display. Accuracy 5% of RDG +1% FSD, Operating temperature 4-49°C...
CDI 6200
Compressed air flow meter, for pipe sizes 1/2 to 1 1/2 inch , clamp on type, accuracy 5% of RDG +1% FSD, operating temperature 4-49 C. With 4-20mA, pulse outputs. Optional MODBUS RTU RS485 O/P, NEMA4 IP67 enclosure...
CDI 6400
Compressed air flow meter, for pipe sizes 2 inch to 6 inch , clamp on type, accuracy 5% of RDG +1% FSD, operating temperature 4-49 C. With 4-20mA, pulse outputs. Optional MODBUS RTU RS485 O/P, NEMA4 IP67 enclosure...
CF916-1/8
Bored through stainless steel fitting for the PT916 probe. 1/8" NPT thread...
CMP3
CMP 3 Pyranometer, ISO Second Class, is suitable for solar irradiance measurements in spectral ranges of 310 to 2800nm up to a maximum of 2,000 W/m² with response time <18 seconds and typical sensitivity 10µV/W/m² that varies less than 5 % from -10 to +40°C. The pyranometer uses a 4mm..
COLGSM-868MHZ
Colinear GSM Wall mount antenna, 3dB gain with 5m of Cable and SMA male connector. Supplied with mounting bracket...
Corrosive Chemical Oval Gear Meter
The CR range of oval gear meters for corrosive chemical applications. Made with a PPS body, Hastelloy C shaft and PPS Rotors...
CP11 – Handheld Instrument for Temp, RH and CO2 Measurements
The CP11 handheld instrument is an economical multiple parameter meter that simultaneously measures and records CO2, humidity and temperature. Operating ranges: -20 to +60°C, 0.1 to 99.95% RH and 0-5,000ppm CO2, calculated Dew Point and Wet Bulb Temperature. 18,000 values with time stamp, automatic recording (%RH/°C/ppm), 99 single values with..
CRE-S100-CAB
RS232 connection cable with CRE subsea connectors, depth rated to 4000 metres..
CS-U-VL10-0
Stainless Steel rounded end probe. 125mmx3.2mm U bead, with 10m VS cable...
CS-UU-VL5-0
Stainless Steel rounded end probe. 125mmx3.2mm UU bead, with 5m VS cable...
0367710
Pyrheliometer Mounting Kit. To mount a CHP1/SHP1 series pyrheliometer to the side plate of the 2AP or Solys 2 Suntracker...
10130055
ComNav G3B GNSS Satellite with G2B Compass Differential GPS (DGPS) correction, G3 Colour Display and 15m cable. Output: NMEA0183. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC (250mA..
8421
DIN Rail mounting clip for head mount transmitters..
GC-04
GEN II radio transmitter for an external thermistor probe. Temperature Range -40 to +70°C, Resolution 0.1°C and Accuracy ±0.2°C (-15 to 40°C). Supplied with 4 x AA Alkaline batteries and stub antenna...
GS-DPA-AC
GS-DPA-AC Dual Port Adapter Input Module for AC current sensors. The GS-DPA-AC can measure electric power current by connecting an AC current sensor (50A clamp/GS-AC50A; 100A clamp/GS-AC100A; 200A clamp/GS-AC200A) single-phase 2 wire, single-phase 3 wire, three-phase 3 wire, to the GL100 Data Logger. Each adapter can be used with up..
CURRENT SHUNT 0-16A
The POC module is meant as Pen Offset High current shunt for recorder ranges of 100mV or 200mV. Maximum continuous current is 16A. Peak current is 20A for 2 min. The shunt has no thermal or current protection and is tested for frequencies below 20 kHz. Fast mounting on all..
CURRENT SHUNT 0-20MA
This module transforms a 0-20 mA signal into a Voltage output by means of a highly accurate resistor (125 Ohm). Full accuracy is guaranteed over the recorder temperature range...
CURRENT SHUNT 4-20MA
This module transforms a 4-20 mA signal into a Voltage output by means of a highly accurate resistor (125 Ohm). Full accuracy is guaranteed over the recorder temperature range...
CUSTOMSCADA
Custom configuration of Superview SCADA Software to match application requirements for NOVUS devices. Price per hour for customisation...
10130056
ComNav G3B GNSS Satellite with G2B Compass Differential GPS (DGPS) correction, G3 Colour Display and 30m cable. Output: NMEA0183. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC (250mA..
DA2597-SMART-CHARGER
Smart charger, 3A output for lithium polymer batteries. Charge time for 8AH batteries 4-6 hours, 22AH batteries 7-10 hours..