Accelerometer, servo type, range +/-2 G , standard type with connector, output +/-5VDC, power supply +/-15vDC, non linearity less than 0.05% FRO, operating temperature -55 to + 95 deg C,. ...
Accelerometer, servo type, range +/-5 G , standard type with connector, output +/-5VDC, power supply +/-15vDC, non linearity less than 0.05% FRO, operating temperature -55 to + 95 deg C,. ...
The HRN 33 is an AC mains voltage monitoring relay with adjustable voltage set point from 167-276 VAC and adjustable trip delay of up to 10 seconds. It is ideal for monitoring mains power dropout. The output contact can be connected to a data logger or controller to indicate mains ...
Active cable for connecting HC2 sensors to USB connector for direct PC interface. HygroClip sensor will be powered by the USB Interface. Cable length 2.8m. ...
Interface cable for connecting HygroFlex, HygroPalm and HygroLog instruments to a USB port on a PC. Instrument will be powered by the AC3009. Requires HW4 software installed on the PC. ...
Stainless steel deep water data logger kit. The kit includes the TK-4014 and ACS-0001 stainless steel container. Temperature Range -40 to +85°C. Temperature logger submersible to a depth of 10km. ...
Waterproof 4-pin plug connector for the following Kipp & Zonen equipment. CMP Series pyranometers, CGR3 & CGR4 pyrgeometers and CVF4 & CNF4 ventilation units. Requires customers own cable wiring. ...
GS-TH Temperature and Humidity Sensor. Temperature Range: -20 to + 85°C, Humidity Range: 0 to 100%RH. The temperature sensor measures the change in capacitance of the conductivity caused by moisture absorption. Usage in an environment with a large quantity of dust, fumes and other organic compound floating about will cause ...
OceanDISP-2K subsea LED display unit suitable for displaying sensor readings from Datataker DT80 and DT85 data loggers. Light activated scrolling display with programmable scroll interval. Suitable for depths up to 2,000m ...
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 1.5m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector. ...
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 3m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector. ...
3 Axis MEMS Accelerometer with a 4-20mA current output. 4-20mA outputs for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...
8 Channel extension for the AMS LAN all-in-one Data Aquisition Units. Provides an additional 8 digital channels through 8 galvanically isolated optocoupler inputs and relay outputs. The AMS-DIG8 is installed on to a new AMS42 via an additional backplane and is only available when purchased with a new AMS42 System. ...
Two metal carry handles for AMS all-in-one Data Aquisition Units. Suitable for the following amplifier measurement systems: AMS42/AMS84, AMS42-LAN16F/AMS84-LAN16F, and AMS42-USB/AMS84-USB. ...
AMS-K Series Cassettes for 5B Modules. Cassettes have a BNC female connection, allowing a Hi and low signal suitable for using 2-way sensors. 5B Modules are available separately. ...
AMS-K Series Cassettes for 5B Modules. Cassettes have a 5-pin socket for connecting a 5-pin screw type terminal block (ZU5STL). 5B Modules are available separately. ...
Accelerometer, servo type, range +/-2 G , standard type with connector, output +/-5VDC, power supply +/-15vDC, non linearity less than 0.05% FRO, operating temperature -55 to + 95 deg C,. ...
Accelerometer, servo type, range +/-5 G , standard type with connector, output +/-5VDC, power supply +/-15vDC, non linearity less than 0.05% FRO, operating temperature -55 to + 95 deg C,. ...
The HRN 33 is an AC mains voltage monitoring relay with adjustable voltage set point from 167-276 VAC and adjustable trip delay of up to 10 seconds. It is ideal for monitoring mains power dropout. The output contact can be connected to a data logger or controller to indicate mains power failure. ...
Active cable for connecting HC2 sensors to USB connector for direct PC interface. HygroClip sensor will be powered by the USB Interface. Cable length 2.8m. ...
Interface cable for connecting HygroFlex, HygroPalm and HygroLog instruments to a USB port on a PC. Instrument will be powered by the AC3009. Requires HW4 software installed on the PC. ...
Stainless steel deep water data logger kit. The kit includes the TK-4014 and ACS-0001 stainless steel container. Temperature Range -40 to +85°C. Temperature logger submersible to a depth of 10km. ...
Waterproof 4-pin plug connector for the following Kipp & Zonen equipment. CMP Series pyranometers, CGR3 & CGR4 pyrgeometers and CVF4 & CNF4 ventilation units. Requires customers own cable wiring. ...
GS-TH Temperature and Humidity Sensor. Temperature Range: -20 to + 85°C, Humidity Range: 0 to 100%RH. The temperature sensor measures the change in capacitance of the conductivity caused by moisture absorption. Usage in an environment with a large quantity of dust, fumes and other organic compound floating about will cause large measurement deviations. Also allows for the calculation of accumulated and dew point temperatures. 14 Byte record length, 127 days logging to internal memory of ...
OceanDISP-2K subsea LED display unit suitable for displaying sensor readings from Datataker DT80 and DT85 data loggers. Light activated scrolling display with programmable scroll interval. Suitable for depths up to 2,000m ...
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 1.5m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector. ...
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 3m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector. ...
3 Axis MEMS Accelerometer with a 4-20mA current output. 4-20mA outputs for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...
8 Channel extension for the AMS LAN all-in-one Data Aquisition Units. Provides an additional 8 digital channels through 8 galvanically isolated optocoupler inputs and relay outputs. The AMS-DIG8 is installed on to a new AMS42 via an additional backplane and is only available when purchased with a new AMS42 System. ...
Two metal carry handles for AMS all-in-one Data Aquisition Units. Suitable for the following amplifier measurement systems: AMS42/AMS84, AMS42-LAN16F/AMS84-LAN16F, and AMS42-USB/AMS84-USB. ...
AMS-K Series Cassettes for 5B Modules. Cassettes have a BNC female connection, allowing a Hi and low signal suitable for using 2-way sensors. 5B Modules are available separately. ...
AMS-K Series Cassettes for 5B Modules. Cassettes have a 5-pin socket for connecting a 5-pin screw type terminal block (ZU5STL). 5B Modules are available separately. ...
Accelerometer, servo type, range +/-2 G , standard type with connector, output +/-5VDC, power supply +/-15vDC, non linearity less than 0.05% FRO, operating temperature -55 to + 95 deg C,. ...
Accelerometer, servo type, range +/-5 G , standard type with connector, output +/-5VDC, power supply +/-15vDC, non linearity less than 0.05% FRO, operating temperature -55 to + 95 deg C,. ...
The HRN 33 is an AC mains voltage monitoring relay with adjustable voltage set point from 167-276 VAC and adjustable trip delay of up to 10 seconds. It is ideal for monitoring mains power dropout. The output contact can be connected to a data logger or controller to indicate mains ...
Active cable for connecting HC2 sensors to USB connector for direct PC interface. HygroClip sensor will be powered by the USB Interface. Cable length 2.8m. ...
Interface cable for connecting HygroFlex, HygroPalm and HygroLog instruments to a USB port on a PC. Instrument will be powered by the AC3009. Requires HW4 software installed on the PC. ...
Stainless steel deep water data logger kit. The kit includes the TK-4014 and ACS-0001 stainless steel container. Temperature Range -40 to +85°C. Temperature logger submersible to a depth of 10km. ...
Waterproof 4-pin plug connector for the following Kipp & Zonen equipment. CMP Series pyranometers, CGR3 & CGR4 pyrgeometers and CVF4 & CNF4 ventilation units. Requires customers own cable wiring. ...
GS-TH Temperature and Humidity Sensor. Temperature Range: -20 to + 85°C, Humidity Range: 0 to 100%RH. The temperature sensor measures the change in capacitance of the conductivity caused by moisture absorption. Usage in an environment with a large quantity of dust, fumes and other organic compound floating about will cause ...
OceanDISP-2K subsea LED display unit suitable for displaying sensor readings from Datataker DT80 and DT85 data loggers. Light activated scrolling display with programmable scroll interval. Suitable for depths up to 2,000m ...
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 1.5m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector. ...
Flat Cable Thermistor Probe for use with Tinytag data loggers. 10K NTC Thermistor, Range -40 to 125°C. The stainless steel probe is 50mm long and 6mm in diameter with a 3m cable. IP66 rating with Hyflon MFA cable and 316 stainless steel sheath. Nickel Plated Brass/Zinc Alloy connector. ...
3 Axis MEMS Accelerometer with a 4-20mA current output. 4-20mA outputs for X, Y and Z axis. Ranges from ±2g to ±40g. M12 5-pin connector. Power Supply 9-36vDC. Dimensions: 34.4 x 34.4 x 38mm. Operating Temperature: -40 to +85°C. ...
8 Channel extension for the AMS LAN all-in-one Data Aquisition Units. Provides an additional 8 digital channels through 8 galvanically isolated optocoupler inputs and relay outputs. The AMS-DIG8 is installed on to a new AMS42 via an additional backplane and is only available when purchased with a new AMS42 System. ...
Two metal carry handles for AMS all-in-one Data Aquisition Units. Suitable for the following amplifier measurement systems: AMS42/AMS84, AMS42-LAN16F/AMS84-LAN16F, and AMS42-USB/AMS84-USB. ...
AMS-K Series Cassettes for 5B Modules. Cassettes have a BNC female connection, allowing a Hi and low signal suitable for using 2-way sensors. 5B Modules are available separately. ...
AMS-K Series Cassettes for 5B Modules. Cassettes have a 5-pin socket for connecting a 5-pin screw type terminal block (ZU5STL). 5B Modules are available separately. ...