Edit Content
Edit Content

Uncategorised

Edit Content

6314208

Red strobe and horn for the MX32 Gas Controller...

9202B3A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply...

9203A1B

Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...

DLOG-4231

gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN..

GSKINKIT-2615C

gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger,..

HPP-110

9V PP3 Power Supply cable for HPS-120 radio modems. Allows the HPS120 transceiver to be powered by a standard 9V PP3 battery. Battery not included...

MCDC5F

Blanking cap for miniature series MCIL type subsea connector, 5 pin female, to suit MCIL5M inline connector or MCBH5M bulkhead connectors...

OMNI-MC-7828G

MC-7828G Grain Moisture Meter with cup measurements. LCD Display, range 0-50% in an operating range of 0-50°C...

RH-W-AH-LCD

RH-W-AH-LCD Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-10vDC or 4-20mA Outputs and LCD Display. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV..

RI-TVV0020L

RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm...

SharpEye 40/40C-M Flame Detector

SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...

SharpEye 40/40D-M Flame Detector

SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt..

SSE232-400-00-IA3-CF

Transparent Serial Server with Flow Control. 4 Configurable RS232/485 ports and one RJ45 connector Ethernet 10/100 Base T port. Powers supply 10-30vDC. Suitable for industrial applications...

Type 624

Type 624 temperature probe with process connection thread, stainless steel stem 6mm diameter, with connection head. Optional compression fitting..

WindObserver75

WindObserver 75 Ultrasonic Anemometer with an IP66 Stainless Steel housing. Wind speed range 0-75m/s, wind direction 0-359 degrees. Optional heating and analogue outputs, plus various connection and base mounting options. Recommended unit for high altitude, Arctic and Antarctic weather monitoring...

XI279C

GSKIN Large Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 18 x 18mm with a 0.5mm thickness. 1m cable terminated in a TEG connector suitable for attaching to a DLOG logger...

6314209

Blue strobe and horn for the MX32 Gas Controller...

9202B3B

Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply...

95.0370

MiniAir 60 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a pulse output (0-960Hz for 0-20m/s). Accuracy ±1% of full scale, ±1.5% of reading. Power supply 4.5-5.5vDC. Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head..

95.0423

MiniAir 6 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±1.5% of reading. Power supply 6.5-26vDC Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium blade..

MCDC5M

Blanking cap for miniature series MCIL type subsea connector, 5 pin male, to suit MCIL5F inline connector or MCBH5F bulkhead connectors...

95.0422

MiniAir 64 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a 2-wire 4-20mA output. Accuracy ±0.5% of full scale, ±1.5% of reading. Power supply 9-24vDC Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium..

050-0000-004

10.6 eV Interchangeable 1/2″ PID lamp..

050-0001-000

11.7 eV Interchangeable 1/2″ PID lamp..
Edit Content

6314208

Red strobe and horn for the MX32 Gas Controller. ...

9202B3A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply. ...

9203A1B

Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs. ...

DLOG-4231

gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN heat flux sensor. Sensor port specifications: Range ±3.13mV @ 1.6µV resolution, plus two temperature sensors. Dimensions 52 x 20 x 15mm. Supplied with USB interface ...

GSKINKIT-2615C

gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger, DLOG-4231; Sensor, GSKIN-X0677C; 2 external temperature probes (1m & 5m cables); carry case; and Mounting tape (MOUNT-1235). Data logger is configured for the calibration settings ...

HPP-110

9V PP3 Power Supply cable for HPS-120 radio modems. Allows the HPS120 transceiver to be powered by a standard 9V PP3 battery. Battery not included. ...

MCDC5F

Blanking cap for miniature series MCIL type subsea connector, 5 pin female, to suit MCIL5M inline connector or MCBH5M bulkhead connectors. ...

OMNI-MC-7828G

MC-7828G Grain Moisture Meter with cup measurements. LCD Display, range 0-50% in an operating range of 0-50°C. ...

RH-W-AH-LCD

RH-W-AH-LCD Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-10vDC or 4-20mA Outputs and LCD Display. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV Stabilized enclosure with an IP54 rating. Dimensions 102 x 105 x 85mm ...

RI-TVV0020L

RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm. ...

SharpEye 40/40C-M Flame Detector

SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC. All via 17 terminal accessed through 2 x M25 or 2 x ¾" NPT cable entries. Heavy duty Copper free Aluminium enclosure with red polyurethane ...

SharpEye 40/40D-M Flame Detector

SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC. All via 17 terminal accessed through ...

SSE232-400-00-IA3-CF

Transparent Serial Server with Flow Control. 4 Configurable RS232/485 ports and one RJ45 connector Ethernet 10/100 Base T port. Powers supply 10-30vDC. Suitable for industrial applications. ...

Type 624

Type 624 temperature probe with process connection thread, stainless steel stem 6mm diameter, with connection head. Optional compression fitting ...

WindObserver75

WindObserver 75 Ultrasonic Anemometer with an IP66 Stainless Steel housing. Wind speed range 0-75m/s, wind direction 0-359 degrees. Optional heating and analogue outputs, plus various connection and base mounting options. Recommended unit for high altitude, Arctic and Antarctic weather monitoring. ...

XI279C

GSKIN Large Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 18 x 18mm with a 0.5mm thickness. 1m cable terminated in a TEG connector suitable for attaching to a DLOG logger. ...

6314209

Blue strobe and horn for the MX32 Gas Controller. ...

9202B3B

Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply. ...

95.0370

MiniAir 60 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a pulse output (0-960Hz for 0-20m/s). Accuracy ±1% of full scale, ±1.5% of reading. Power supply 4.5-5.5vDC. Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium blade turbine suitable for non-aggressive gas flow measurements. Part Ref MINI60134 ...

95.0423

MiniAir 6 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±1.5% of reading. Power supply 6.5-26vDC Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium blade turbine suitable for non-aggressive gas flow measurements. Part Ref MINI06134 ...

MCDC5M

Blanking cap for miniature series MCIL type subsea connector, 5 pin male, to suit MCIL5F inline connector or MCBH5F bulkhead connectors. ...

95.0422

MiniAir 64 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a 2-wire 4-20mA output. Accuracy ±0.5% of full scale, ±1.5% of reading. Power supply 9-24vDC Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium blade turbine suitable for non-aggressive gas flow measurements. Part Ref MINI64134 ...

050-0000-004

10.6 eV Interchangeable 1/2″ PID lamp ...

050-0001-000

11.7 eV Interchangeable 1/2″ PID lamp ...

6314208

Red strobe and horn for the MX32 Gas Controller...

9202B3A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply...

9203A1B

Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...

DLOG-4231

gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN..

GSKINKIT-2615C

gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger,..

HPP-110

9V PP3 Power Supply cable for HPS-120 radio modems. Allows the HPS120 transceiver to be powered by a standard 9V PP3 battery. Battery not included...

MCDC5F

Blanking cap for miniature series MCIL type subsea connector, 5 pin female, to suit MCIL5M inline connector or MCBH5M bulkhead connectors...

OMNI-MC-7828G

MC-7828G Grain Moisture Meter with cup measurements. LCD Display, range 0-50% in an operating range of 0-50°C...

RH-W-AH-LCD

RH-W-AH-LCD Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-10vDC or 4-20mA Outputs and LCD Display. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV..

RI-TVV0020L

RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm...

SharpEye 40/40C-M Flame Detector

SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...

SharpEye 40/40D-M Flame Detector

SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt..

SSE232-400-00-IA3-CF

Transparent Serial Server with Flow Control. 4 Configurable RS232/485 ports and one RJ45 connector Ethernet 10/100 Base T port. Powers supply 10-30vDC. Suitable for industrial applications...

Type 624

Type 624 temperature probe with process connection thread, stainless steel stem 6mm diameter, with connection head. Optional compression fitting..

WindObserver75

WindObserver 75 Ultrasonic Anemometer with an IP66 Stainless Steel housing. Wind speed range 0-75m/s, wind direction 0-359 degrees. Optional heating and analogue outputs, plus various connection and base mounting options. Recommended unit for high altitude, Arctic and Antarctic weather monitoring...

XI279C

GSKIN Large Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 18 x 18mm with a 0.5mm thickness. 1m cable terminated in a TEG connector suitable for attaching to a DLOG logger...

6314209

Blue strobe and horn for the MX32 Gas Controller...

9202B3B

Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply...

95.0370

MiniAir 60 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a pulse output (0-960Hz for 0-20m/s). Accuracy ±1% of full scale, ±1.5% of reading. Power supply 4.5-5.5vDC. Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head..

95.0423

MiniAir 6 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±1.5% of reading. Power supply 6.5-26vDC Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium blade..

MCDC5M

Blanking cap for miniature series MCIL type subsea connector, 5 pin male, to suit MCIL5F inline connector or MCBH5F bulkhead connectors...

95.0422

MiniAir 64 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a 2-wire 4-20mA output. Accuracy ±0.5% of full scale, ±1.5% of reading. Power supply 9-24vDC Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium..

050-0000-004

10.6 eV Interchangeable 1/2″ PID lamp..

050-0001-000

11.7 eV Interchangeable 1/2″ PID lamp..

Contact us

8:30 AM to 5 PM Monday to Thursday
8:30 AM to 3 PM on Friday.

A real person will answer the phone and deal with your enquiry

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Enquire now