TMS3000-BAD
TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with analog O/P and Profibus O/P..
TT-IH-CVO-250
TT-IH-CVO High Temperature Immersion Sensor suitable for monitoring temperature in pipework systems. PT100 temperature sensing elements housed in a 250mm x 6mm diameter Stainless Steel probe with a 1m cable back to an IP65 housing. Selectable 4-20mA or 0-10vDC output options with 4 pre-set selectable temperature ranges (-10 to +40°C,..
RMS1-OR-110168-6V-GR-MB
Remote I/O Module, 16 Opto Isolated digital Inputs, 8 Relay Digital Outputs and 6 Analog Inputs 0-10V. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting...
RMS1-OR-11088-6V-GR-MB
Remote I/O Module, 8 Opto Isolated digital Inputs, 8 Relay Digital Outpus and 6 Analog Inputs 0-10V. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting...
0373900-001
PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 5m length...
0373900-003
PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 15m length...
10130053B
ComNav G2 GNSS Satellite with G2 Compass Differential GPS (DGPS) correction, G2 Navigator Colour Display and 30m cable. Output: NMEA0183. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC..
111-90
P11 Rod Glass Combination pH Electrode for a pH range of 0-14. Combination electrode with a Silver Chloride, liquid filled, single annular ceramic junction. Eo point -25 to +25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 100 C. Suitable for..
6314208
Red strobe and horn for the MX32 Gas Controller...
9202B3A
Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply...
9203A1B
Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...
DLOG-4231
gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN..
GSKINKIT-2615C
gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger,..
HPP-110
9V PP3 Power Supply cable for HPS-120 radio modems. Allows the HPS120 transceiver to be powered by a standard 9V PP3 battery. Battery not included...
OMNI-MC-7828G
MC-7828G Grain Moisture Meter with cup measurements. LCD Display, range 0-50% in an operating range of 0-50°C...
RH-W-AH-LCD
RH-W-AH-LCD Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-10vDC or 4-20mA Outputs and LCD Display. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV..
RI-TVV0020L
RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm...
SharpEye 40/40C-M Flame Detector
SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...
SharpEye 40/40D-M Flame Detector
SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt..
SSE232-400-00-IA3-CF
Transparent Serial Server with Flow Control. 4 Configurable RS232/485 ports and one RJ45 connector Ethernet 10/100 Base T port. Powers supply 10-30vDC. Suitable for industrial applications...
Type 624
Type 624 temperature probe with process connection thread, stainless steel stem 6mm diameter, with connection head. Optional compression fitting..
WindObserver75
WindObserver 75 Ultrasonic Anemometer with an IP66 Stainless Steel housing. Wind speed range 0-75m/s, wind direction 0-359 degrees. Optional heating and analogue outputs, plus various connection and base mounting options. Recommended unit for high altitude, Arctic and Antarctic weather monitoring...
XI279C
GSKIN Large Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 18 x 18mm with a 0.5mm thickness. 1m cable terminated in a TEG connector suitable for attaching to a DLOG logger...
6314209
Blue strobe and horn for the MX32 Gas Controller...