9202B2B
Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.O. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply...
9203A1A2
Solenoid and alarm driver, 1 channel driver output, NPN input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
9203B1A2
Solenoid and alarm driver, ATEX approved 1 channel driver output, NPN input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
HPA-110
4dBi omni-directional dipole antenna, up to 500m service range, 7" high with SMA connector..
HPP-120-US
120VAC Power Supply, standard US AC plug pack adapter..
HPS-120-SMAMFDRA
HPS 120 Antenna, 1/4 wave, with right angled SMA male connection. 2.4 GHz..
MIEX06124
MiniAir 6EX Mini vane anemometer. Sensing head 22mm diameter x 28mm, probe length 175mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range -10 to +80°C. Plastic sensing..
RMS1-OX-110160-0X-GR-MB
Remote Inputs Module, 16 Opto isolated digital inputs. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting...
SGR Series Rotary Transducer For Torque, Speed & Power Measurements – External Electronics
These SGR Series Transducers can be used to monitoring bi-directional rotary or static torque with an external electronics box. An integrated speed sensor enable the direct measurements of transmitted power and RPM. The SGR Series Transducers operate using a four-element strain gauge wheatstone bridge, which connects to a microcontroller to..
SGR522
SGR522 TorqSense Torque sensor with variable analogue outputs for Torque, Speed and Power measurements with integral electronics. Torque ranges from 0-175mNm to 0-13,000 Nm and 360 Pulse/Revolution...
TMS3000-BD
TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with digital O/P interface ( bus system )..
TT-IH-CVO
TT-IH-CVO High Temperature Immersion Sensor suitable for monitoring temperature in pipework systems. PT100 temperature sensing elements housed in a 150mm x 6mm diameter Stainless Steel probe with a 1m cable back to an IP65 housing. Selectable 4-20mA or 0-10vDC output options with 4 pre-set selectable temperature ranges (-10 to +40°C,..
RMS1-TX-110160-0X-GR-MB
Remote Inputs Module, 16 NPN digital inputs. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting..
TMS3000-BAD
TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with analog O/P and Profibus O/P..
TT-IH-CVO-250
TT-IH-CVO High Temperature Immersion Sensor suitable for monitoring temperature in pipework systems. PT100 temperature sensing elements housed in a 250mm x 6mm diameter Stainless Steel probe with a 1m cable back to an IP65 housing. Selectable 4-20mA or 0-10vDC output options with 4 pre-set selectable temperature ranges (-10 to +40°C,..
RMS1-OR-110168-6V-GR-MB
Remote I/O Module, 16 Opto Isolated digital Inputs, 8 Relay Digital Outputs and 6 Analog Inputs 0-10V. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting...
RMS1-OR-11088-6V-GR-MB
Remote I/O Module, 8 Opto Isolated digital Inputs, 8 Relay Digital Outpus and 6 Analog Inputs 0-10V. RS232/RS485 Modbus ASCII/RTU Communication, Wide power supply range: 10 up to 30vDC, DIN rail mounting...
0373900-001
PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 5m length...
0373900-003
PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 15m length...
10130053B
ComNav G2 GNSS Satellite with G2 Compass Differential GPS (DGPS) correction, G2 Navigator Colour Display and 30m cable. Output: NMEA0183. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC..
111-90
P11 Rod Glass Combination pH Electrode for a pH range of 0-14. Combination electrode with a Silver Chloride, liquid filled, single annular ceramic junction. Eo point -25 to +25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 100 C. Suitable for..
6314208
Red strobe and horn for the MX32 Gas Controller...
9202B3A
Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply...
9203A1B
Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...