RI-TVV0020L
RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm...
SharpEye 40/40C-M Flame Detector
SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...
SharpEye 40/40D-M Flame Detector
SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt..
Type 624
Type 624 temperature probe with process connection thread, stainless steel stem 6mm diameter, with connection head. Optional compression fitting..
WindObserver75
WindObserver 75 Ultrasonic Anemometer with an IP66 Stainless Steel housing. Wind speed range 0-75m/s, wind direction 0-359 degrees. Optional heating and analogue outputs, plus various connection and base mounting options. Recommended unit for high altitude, Arctic and Antarctic weather monitoring...
XI279C
GSKIN Large Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 18 x 18mm with a 0.5mm thickness. 1m cable terminated in a TEG connector suitable for attaching to a DLOG logger...
6314209
Blue strobe and horn for the MX32 Gas Controller...
9202B3B
Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply...
95.0370
MiniAir 60 Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-40m/s with a pulse output (0-960Hz for 0-20m/s). Accuracy ±1% of full scale, ±1.5% of reading. Power supply 4.5-5.5vDC. Sensor is supplied with 2m cable. Operating range -10 to +80°C. Plastic sensing head..
95.0423
MiniAir 6 Macro vane anemometer. Sensing head 80mm diameter x 85mm, probe length 225mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±1.5% of reading. Power supply 9-26vDC Sensor is supplied with 5m cable. Operating range -10 to +80°C. Plastic sensing head with Aluminium blade..
050-0000-004
10.6 eV Interchangeable 1/2″ PID lamp..
050-0001-000
11.7 eV Interchangeable 1/2″ PID lamp..
111-993
P11/CER/DJ/LiCl Glass Bodied Non Aqueous pH Electrode for a pH range of 0-14. Combination electrode with a Silver Chloride, liquid filled, double annular ceramic junction. Eo point -25 to +25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 80 C. Suitable..
9203A1B1
Solenoid and alarm driver, 2 channel driver output, 2 PNP inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...
9203B1B
Solenoid and alarm driver, ATEX approved 2 channel driver output, digital switch input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...
BM25KITCHD25
BM25 Intrinsically Safe Trickle Charge Kit. Kit includes two IS power supply and wiring arrangement with 25m of cable. The Dual BM25 Intrinsically Safe Trickle charger which includes an additional IS power module, is required to provide an adequate trickle charge rate to continuously maintain a BM25 battery when using..
SharpEye 40/40C-LB Flame Detector
SharpEye 40/40C-LB Integrated Ultraviolet Infrared (UV/IR) Flame Detector. 2 sensitivity ranges and Field of View of 100° Horizontal & 95° Vertical. Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...
SharpEye 40/40D-LB Flame Detector
SharpEye 40/40D-LB Ultra Fast Ultraviolet Infrared (UV/IR) Flame Detector. Spectral Response: Ultraviolet: 0.185 to 0.260µm; Infrared: 2.5 to 3.0µm, 3 sensitivity ranges and Field of View of 100° Horizontal & 95° Vertical. Standard (<5 secs), Ultra Fast (<20msecs) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt Free..
Type 595
Type 595 temperature probe with stainless steel stem 6mm diameter, inegral 100mm extension, with connection head...
WindObserver90
WindObserver 90 Ultrasonic Anemometer with an IP66 Stainless Steel housing. Wind speed range 0-100m/s, wind direction 0-359 degrees . Optional heating and analogue outputs, plus various connection and base mounting options. Ideal for extreme weather conditions...
9203A1B2
Solenoid and alarm driver, 2 channel driver output, 2 NPN inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...
BM25KITCHD50
BM25 Intrinsically Safe Trickle Charge Kit. Kit includes two IS power supply and wiring arrangement with 50m of cable. The Dual BM25 Intrinsically Safe Trickle charger which includes an additional IS power module, is required to provide an adequate trickle charge rate to continuously maintain a BM25 battery when using..
MR42 Rain Sensor
The MR42 is a capacitance type rain sensor with an output (open collector) for either raining or not raining condition. The green sensor surface sensor is coated to protect against pollution and is heated a few degrees above ambient to ensure that it is not affected by fog or dew,..
BM25KITCHD100
BM25 Intrinsically Safe Trickle Charge Kit. Kit includes two IS power supply and wiring arrangement with 100m of cable. The Dual BM25 Intrinsically Safe Trickle charger which includes an additional IS power module, is required to provide an adequate trickle charge rate to continuously maintain a BM25 battery when using..