Head Mounted Transmitters

Head-mounted transmitters are compact, puck-shaped devices designed for direct installation within the protective connection head of a temperature probe. Their close proximity to the sensor minimises the risk of signal degradation and electrical noise, ensuring highly accurate measurements. These transmitters convert the low-level signal from a thermocouple or RTD into a robust, standardised 4-20mA or digital signal, which can be reliably transmitted over long distances to a control system. Their small form factor and integration with the sensor assembly make them ideal for seamless and efficient temperature monitoring in a wide range of industrial applications.

Edit Content

PR 5331 2-Wire Programmable Transmitter

The PR 5331 offers the most flexibility in the PR range of head-mounted transmitters. The PR 5331 is a universal input device, accepting RTD, Thermocouples, Linear Resistance and Bi-Polar mV signals. This broad capability offers significant advantages, allowing for a single transmitter type to be stocked for multiple applications, thereby ...

PR 5332 2-Wire Programmable RTD Transmitter

The PR 5332 is designed to convert 2-, 3-, or 4-Wire RTD and linear resistance measurements to a linearised 4-20mA signal. The PR 5332 can handle inputs from PT100, PT1000 and Ni100, Ni1000 sensors and resistances up to 5,000Ω. The PR 5332 is engineered for superior performance, featuring an impressive ...

PR 5333 2-Wire Programmable Transmitter

The PR 5333 is a specialised RTD and resistance transmitter engineered for applications demanding rapid response and higher resistance measurement. The unit features a faster response time, ensuring quick and accurate signal conversion from RTD sensors.While it offers a slightly lower accuracy than the PR 5332, its enhanced capabilities are ...

PR 5334 2-Wire Programmable Transmitter

The PR 5334 is a 2-wire transmitter designed for precise thermocouple and mV signal conversion, making it a perfect fit for a variety of specific applications. Its ability to accept both thermocouple temperature inputs and mV signals in a single, compact unit makes it uniquely suited for solar panel monitoring, ...

PR 5335 2-Wire Transmitter with HART 5 Protocol

The PR 5335 is a universal 2-wire temperature transmitter with embedded HART 5 protocol, offering a powerful combination of analogue and digital communication. It is designed to convert a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. The HART 5 protocol is ...

PR 5337 2-Wire Transmitter with HART 7 Protocol

The PR 5337 is a universal 2-wire temperature transmitter that combines exceptional versatility with the latest HART communication technology. It converts a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. Its key differentiator is the user-selectable HART protocol, allowing it to operate ...

PR 5343 2-Wire Programmable Level Transmitter

The PR 5343 is a 2-wire transmitter designed for highly accurate resistance measurement, a function that makes it a dedicated level transmitter. It is a cost-effective solution for converting linear or non-linear resistance variations into a standard 4-20mA output. Its core applications involve measuring ...

PR 5437 2-Wire HART 7 Temperature Transmitter

The PR 5437 is a high-end, 2-wire universal HART temperature transmitter designed for the most critical and demanding applications. It sets itself apart with a "true dual input" design, featuring a high-density 7-terminal configuration that allows it to accept a wide variety of sensor combinations, including ...

PR 5450 Profibus PA Transmitter

The PR 5450 is a high-performance PROFIBUS PA temperature transmitter designed for demanding industrial environments. It provides universal input capability for a wide range of RTD, thermocouple, mV, and resistance sensors, making it an extremely versatile and valuable asset for digital bus networks. A key feature is its true dual-input ...

TxBlock-USB Head Mounted Temperature Transmitter

The Novus TxBlock USB is a head-mounted temperature transmitter known for its versatility and simple configuration. Its universal input accepts a wide range of temperature sensors, including various RTDs (PT100, PT1000, NTC) and thermocouples (Type J, K, T, E, N, R, S, B), as well as ...
Edit Content

PR 5331 2-Wire Programmable Transmitter

The PR 5331 offers the most flexibility in the PR range of head-mounted transmitters. The PR 5331 is a universal input device, accepting RTD, Thermocouples, Linear Resistance and Bi-Polar mV signals. This broad capability offers significant advantages, allowing for a single transmitter type to be stocked for multiple applications, thereby drastically simplifying inventory management and reducing maintenance overhead. Beyond its versatility, the PR 5331 is engineered for superior performance, featuring an impressive measurement accuracy of ...

PR 5332 2-Wire Programmable RTD Transmitter

The PR 5332 is designed to convert 2-, 3-, or 4-Wire RTD and linear resistance measurements to a linearised 4-20mA signal. The PR 5332 can handle inputs from PT100, PT1000 and Ni100, Ni1000 sensors and resistances up to 5,000Ω. The PR 5332 is engineered for superior performance, featuring an impressive measurement accuracy of better than 0.05% of the selected range, ensuring dependable and precise signal conversion to a standard 4-20mA current output. Its robust design ...

PR 5333 2-Wire Programmable Transmitter

The PR 5333 is a specialised RTD and resistance transmitter engineered for applications demanding rapid response and higher resistance measurement. The unit features a faster response time, ensuring quick and accurate signal conversion from RTD sensors.While it offers a slightly lower accuracy than the PR 5332, its enhanced capabilities are tailored for specific industrial needs. It also accommodates a higher resistance range, expanding its utility for a broader scope of resistive sensors. Crucially, the PR ...

PR 5334 2-Wire Programmable Transmitter

The PR 5334 is a 2-wire transmitter designed for precise thermocouple and mV signal conversion, making it a perfect fit for a variety of specific applications. Its ability to accept both thermocouple temperature inputs and mV signals in a single, compact unit makes it uniquely suited for solar panel monitoring, where it can handle both pyranometer output and ambient temperature measurements using thermocouples. With integrated galvanic isolation, high measurement accuracy, and NAMUR NE43/NE21 sensor error ...

PR 5335 2-Wire Transmitter with HART 5 Protocol

The PR 5335 is a universal 2-wire temperature transmitter with embedded HART 5 protocol, offering a powerful combination of analogue and digital communication. It is designed to convert a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. The HART 5 protocol is superimposed on this signal, allowing for remote configuration, calibration, and diagnostics using a HART-compatible host or handheld communicator. This provides the dual benefits of reliable ...

PR 5337 2-Wire Transmitter with HART 7 Protocol

The PR 5337 is a universal 2-wire temperature transmitter that combines exceptional versatility with the latest HART communication technology. It converts a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. Its key differentiator is the user-selectable HART protocol, allowing it to operate in either HART 5 or the more advanced HART 7 mode. This flexibility makes the PR 5337 a future-proof investment, as it can be deployed ...

PR 5343 2-Wire Programmable Level Transmitter

The PR 5343 is a 2-wire transmitter designed for highly accurate resistance measurement, a function that makes it a dedicated level transmitter. It is a cost-effective solution for converting linear or non-linear resistance variations into a standard 4-20mA output. Its core applications involve measuring signals from Ohmic level sensors or valve positions, which rely on resistance changes to indicate position or level. With its unique process calibration ...

PR 5437 2-Wire HART 7 Temperature Transmitter

The PR 5437 is a high-end, 2-wire universal HART temperature transmitter designed for the most critical and demanding applications. It sets itself apart with a "true dual input" design, featuring a high-density 7-terminal configuration that allows it to accept a wide variety of sensor combinations, including two 4-wire RTDs. This enables advanced features like sensor redundancy, which provides an automatic backup in case of primary sensor failure, and sensor ...

PR 5450 Profibus PA Transmitter

The PR 5450 is a high-performance PROFIBUS PA temperature transmitter designed for demanding industrial environments. It provides universal input capability for a wide range of RTD, thermocouple, mV, and resistance sensors, making it an extremely versatile and valuable asset for digital bus networks. A key feature is its true dual-input functionality, which enables sensor redundancy and drift detection. This allows for proactive maintenance and ensures continuous, reliable operation in critical applications. With exceptional accuracy, robust ...

TxBlock-USB Head Mounted Temperature Transmitter

The Novus TxBlock USB is a head-mounted temperature transmitter known for its versatility and simple configuration. Its universal input accepts a wide range of temperature sensors, including various RTDs (PT100, PT1000, NTC) and thermocouples (Type J, K, T, E, N, R, S, B), as well as mV signals. The standout feature is the built-in micro-USB port, which allows for direct connection to a PC or smartphone for quick and ...

Head-mounted transmitters are compact, puck-shaped devices designed for direct installation within the protective connection head of a temperature probe. Their close proximity to the sensor minimises the risk of signal degradation and electrical noise, ensuring highly accurate measurements. These transmitters convert the low-level signal from a thermocouple or RTD into a robust, standardised 4-20mA or digital signal, which can be reliably transmitted over long distances to a control system. Their small form factor and integration with the sensor assembly make them ideal for seamless and efficient temperature monitoring in a wide range of industrial applications.

PR 5331 2-Wire Programmable Transmitter

The PR 5331 offers the most flexibility in the PR range of head-mounted transmitters. The PR 5331 is a universal input device, accepting RTD, Thermocouples, Linear Resistance and Bi-Polar mV signals. This broad capability offers significant advantages, allowing for a single transmitter type to be stocked for multiple applications, thereby ...

PR 5332 2-Wire Programmable RTD Transmitter

The PR 5332 is designed to convert 2-, 3-, or 4-Wire RTD and linear resistance measurements to a linearised 4-20mA signal. The PR 5332 can handle inputs from PT100, PT1000 and Ni100, Ni1000 sensors and resistances up to 5,000Ω. The PR 5332 is engineered for superior performance, featuring an impressive ...

PR 5333 2-Wire Programmable Transmitter

The PR 5333 is a specialised RTD and resistance transmitter engineered for applications demanding rapid response and higher resistance measurement. The unit features a faster response time, ensuring quick and accurate signal conversion from RTD sensors.While it offers a slightly lower accuracy than the PR 5332, its enhanced capabilities are ...

PR 5334 2-Wire Programmable Transmitter

The PR 5334 is a 2-wire transmitter designed for precise thermocouple and mV signal conversion, making it a perfect fit for a variety of specific applications. Its ability to accept both thermocouple temperature inputs and mV signals in a single, compact unit makes it uniquely suited for solar panel monitoring, ...

PR 5335 2-Wire Transmitter with HART 5 Protocol

The PR 5335 is a universal 2-wire temperature transmitter with embedded HART 5 protocol, offering a powerful combination of analogue and digital communication. It is designed to convert a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. The HART 5 protocol is ...

PR 5337 2-Wire Transmitter with HART 7 Protocol

The PR 5337 is a universal 2-wire temperature transmitter that combines exceptional versatility with the latest HART communication technology. It converts a wide range of inputs—including RTD, thermocouple, linear resistance, and bipolar mV signals—into a standard 4-20mA output. Its key differentiator is the user-selectable HART protocol, allowing it to operate ...

PR 5343 2-Wire Programmable Level Transmitter

The PR 5343 is a 2-wire transmitter designed for highly accurate resistance measurement, a function that makes it a dedicated level transmitter. It is a cost-effective solution for converting linear or non-linear resistance variations into a standard 4-20mA output. Its core applications involve measuring ...

PR 5437 2-Wire HART 7 Temperature Transmitter

The PR 5437 is a high-end, 2-wire universal HART temperature transmitter designed for the most critical and demanding applications. It sets itself apart with a "true dual input" design, featuring a high-density 7-terminal configuration that allows it to accept a wide variety of sensor combinations, including ...

PR 5450 Profibus PA Transmitter

The PR 5450 is a high-performance PROFIBUS PA temperature transmitter designed for demanding industrial environments. It provides universal input capability for a wide range of RTD, thermocouple, mV, and resistance sensors, making it an extremely versatile and valuable asset for digital bus networks. A key feature is its true dual-input ...

TxBlock-USB Head Mounted Temperature Transmitter

The Novus TxBlock USB is a head-mounted temperature transmitter known for its versatility and simple configuration. Its universal input accepts a wide range of temperature sensors, including various RTDs (PT100, PT1000, NTC) and thermocouples (Type J, K, T, E, N, R, S, B), as well as ...