Description
Features
- Single or dual channel gas controller
- Up to 4 or 8 channels available using the MX32’s digital technology
- Manages both digital lines and analog channels
- Base unit allows up to 2 wheatstone bridge detector inputs without any additional modules
- Five programmable events per detector (1 to 3 alarms, underscale, overscale) and fault event
- Two extra MOSFET outputs for driving the audible and visual alarms
- Front panel LEDs allow for a quick and basic overview of the installation and oboard alarm buzzer
- Easy to read large graphic and multi-language LCD back-lit display
- Smart keys for embedded menus
Applications
- Boiler Room Monitoring
- Food Industry
- HVAC
- Automotive Plants
- Steel Mills
- Water Water Treatment Plants
- Petrochemical
- Laboratories
Specifications
General Specifications
Dimensions: | 265 x 266 x 96mm |
Ingress protection | IP55 |
Cable entries:
|
5 M16 cable glands, 4 to 8 mm² (8 to 11 AWG) outer diameter cable 2 M20 cable glands, 6 to 12 mm² (7 to 9 AWG) outer diameter cable |
Display:
|
LCD back-lit display + smart keys Display in video inverse in case of fault Customizable by user (display 1 to 8 channels simultaneously, fixed or scrolling, on events…) Bar graph with alarm threshold |
Visual indicators: | 7 LEDs per line, 1 LED fault indicator |
Buttons: | 5 smart keys, 1 audible alarm accept/reset button |
Operating Environment: | Temp: -20°C to +50°C, Humidity 5 – 95%RH |
Power Supply: | 100-240vAC 50-60 Hz (35W) or 22-28vDC, (92W max) |
Optional Battery: | Embedded back up power supply in option (0.6 Ah) |
Consumption: | 250 mA max (without module or detector) |
Monitored Channels
Digital lines:
|
2 maximum RS-485 communication, proprietary protocol, 9600 Baud 2 twisted shielded-pair cable |
Analog channels:
|
2 maximum (4-20mA or Wheatstone bridge 0-23 mA analog signal input (4 to 20 mA reserved for measurement) 120 Ohm load resistance 2 or 3-core shielded cable |
Max current output per line: | 0.65 to 1A with internal AC power or 1.5A with external DC power |
Max current output in total: | 0.65 to 1A with internal AC power or 2 x 1.5A with external DC power |
Alarms
Per channel:
|
5 alarm levels (A1, A2, A3, Overscale, Underscale) + 1 Fault Catalytic bead over range protection |
Programmable thresholds: | Instantaneous or averaged values, rising or falling alarms, manual or automatic acknowledgement |
On-board relays:
|
4 fully programmable alarm relays 1 fault relay (non-configurable) Dry contact relay DPCO relays with contact rating of 250vAC, 2 A (inductive) |
External relays:
|
Up to 16 fully programmable alarm relays Dry contact relay, DPCO relays with contact rating of 250vAC, 2 A (inductive) |
Digital outputs: | RS-485 Modbus RTU serial link |
Analog outputs: | Up to 8 outputs (4-20mA) |