Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR5337D HART 7 Programmable ATEX Temperature Transmitter

Home / Our Brands / PR Electronics / PR Temperature Transmitters / Head Mounted / 2-Wire HART Transmitters / PR5337D HART 7 Protocol ATEX Transmitter

PR5337D HART 7 Protocol ATEX Transmitter

The PR 5337D is an intrinsically safe, head-mounted 2-wire transmitter with selectable HART 5 or HART 7 communication. It converts supported RTD, thermocouple, linear resistance and bipolar millivolt inputs into a 4-20 mA output, with digital access to measurement values, configuration and device status. Designed for DIN form B sensor heads, it provides flexible measurement for suitably designed hazardous-area installations.

Temperature and Process Signal Conversion

The 5337D supports linearised temperature measurement with compatible RTDs and thermocouples. Suitable two-sensor arrangements allow individual readings, differential measurement or averaging, enabling the transmitter to report a temperature or compare measurements from two locations.

Resistance and bipolar millivolt inputs extend its use to compatible resistive sensors and low-level voltage sources. Configuration matches the input type and measurement function to the application.

Selectable HART Communication

The HART revision can be configured as HART 5 or HART 7 to match the connected equipment. This allows integration with compatible existing systems while providing access to additional HART 7 functions where supported.

HART 7 features include longer device tags, enhanced burst communication, time-stamped event notifications and flexible mapping of measurement variables. These functions help compatible control and asset-management systems access process information alongside the main analogue measurement.

Two-Wire Analogue and Digital Output

In conventional point-to-point operation, the 4–20 mA output represents the configured process value. The same two wires supply transmitter power and carry HART communication.

This arrangement allows digital access through the measurement loop without a separate communication cable. Any barrier or isolator through which HART access is required must support transmission of the HART signal.

Configuration and Diagnostic Access

The 5337D can be configured using compatible HART equipment or PR Electronics PReset software with a suitable Loop Link interface. Settings are selected to match the sensors, measurement range and required output behaviour.

Measurement variables and associated status information are available digitally. Continuous checks of stored data and sensor error functions support identification of abnormal conditions, helping maintenance teams distinguish a process change from a measurement problem.

Intrinsically Safe Installation

The 5337D carries hazardous-area approvals, including ATEX and IECEx, for installation within the applicable certification conditions. Its approval coverage supports specified hazardous gas and dust environments.

The complete measurement arrangement must be compatible, including the sensor, enclosure, associated barrier or isolator and loop wiring. Selection should account for the required protection level, ambient conditions, electrical limits and HART communication path.

Choosing Between the 5335D and 5337D

Both models provide flexible sensor inputs, a 4-20 mA output and HART communication for intrinsically safe installations. The 5335D uses HART 5, while the 5337D offers selectable HART 5 or HART 7 with additional communication functions.

Choose according to the capabilities of the receiving system and the measurement information required, then confirm the sensor connections and installation approvals for the selected model.

Options

TypeVersion
5337A: General Purpose, Zone 2, Div 2
D: Zone 0, 1, 2, 21, 22, M1/Div 1, Div 2

Applications

Connect compatible RTD or thermocouple sensors to control and monitoring systems through a suitably designed intrinsically safe loop.
Use two compatible sensors to measure a temperature difference or calculate an average.
Select HART 5 for compatible existing equipment or HART 7 for enhanced communication, variable mapping and event notifications.
Convert supported linear resistance or bipolar millivolt signals into a standard 4–20 mA output.

Frequently Asked Questions

▶ Q: Which inputs does the 5337D accept?
A: Supported RTDs, thermocouples, linear resistance and bipolar millivolt signals.
▶ Q: Does it support HART 5 and HART 7?
A: Yes. The protocol revision is selectable through configuration.
▶ Q: What additional functions does HART 7 provide?
A: Longer device tags, enhanced burst communication, time-stamped event notifications and flexible variable mapping.
▶ Q: Does it also provide a 4-20 mA output?
A: Yes. In conventional point-to-point operation, the current represents the configured process measurement.
▶ Q: Can it measure two temperatures?
A: Compatible arrangements support individual, differential or average temperature measurement.
▶ Q: How is it configured?
A: Through compatible HART equipment or PReset software with a suitable Loop Link interface.
▶ Q: Where is it mounted?
A: Inside a compatible DIN form B sensor head.
▶ Q: How does it differ from the 5337A?
A: The 5337D provides intrinsically safe hazardous-area approval coverage. Installation must meet its certification conditions.

5337D

5337D

PR 5337D 2-Wire Programmable Transmitters with HART 5/7 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 or 7 Protocol. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 8-30vDC @ 0.7W Max. 1.5kVAC Galvanic Isolation. Namur NE21, NE43 and NE89. Approvals: ATEX, IECEx, FM, CSA & INMETRO; DNV Certification; SIL Hardware Assessment. Operating Temp: -40 to +85°C.

£440.00
Add to Basket More Info
5909

5909

USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.

£240.00
Add to Basket More Info
8421

8421

DIN Rail mounting clip for head mount transmitters

£6.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000