Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR5335A HART 5 Programmable Temperature Transmitter

Home / Our Brands / PR Electronics / PR Temperature Transmitters / Head Mounted / 2-Wire HART Transmitters / PR5335A HART 5 Protocol Transmitter

PR5335A HART 5 Protocol Transmitter

The PR 5335A is a head-mounted 2-wire transmitter that combines flexible sensor inputs with a 4-20 mA output and HART 5 communication. It accepts supported RTDs, thermocouples, linear resistance and bipolar millivolt signals, providing a configurable connection between field sensors and industrial monitoring or control systems. Its compact housing fits compatible DIN form B sensor heads.

Temperature and Process Signal Conversion

The 5335A supports linearised temperature measurement with platinum and nickel RTDs, including PT100 and PT1000, alongside supported thermocouple types. RTD and resistance inputs accommodate two-, three- and four-wire sensor connections, with cable compensation appropriate to the selected arrangement.

It also converts linear resistance changes and bipolar millivolt signals into a standard current output, allowing suitable resistive sensors and low-level voltage sources to connect to receiving equipment.

Differential and Average Measurement

Compatible two-sensor arrangements allow the transmitter to calculate a temperature difference or average. Differential measurement can compare two locations, while averaging combines the readings into a single reported value.

The sensor types, wiring arrangement and configured function must match the intended measurement. These functions provide alternatives to straightforward individual sensor measurement.

HART 5 Communication

HART communication provides digital access over the same two-wire connection used for power and the current output. In conventional point-to-point operation, the 4-20 mA signal represents the configured process value while compatible HART equipment accesses additional digital information and settings.

This allows configuration and measurement access through the loop, supporting commissioning and maintenance without a separate communication cable to the transmitter.

Configuration and Fault Indication

The 5335A can be configured through compatible HART equipment or using PR Electronics PReset software with a suitable Loop Link interface. Settings are matched to the sensor, measurement range and required output behaviour.

Programmable sensor error indication provides a defined output response when a sensor fault is detected. Receiving equipment can use this response to distinguish a measurement problem from a normal process reading.

Installation and Selection

The loop-powered design uses two wires for both supply and output. Before installation, confirm the sensor connections, available loop voltage and receiving equipment requirements.

The 5335A suits general industrial installations and permitted Zone 2/22 applications under its certification conditions. Where an intrinsically safe installation requires the approval coverage of the 5335D, select that version and check the complete circuit against its installation requirements.

Options

Type Version
5335 A: General Purpose, Zone 2, Div 2
D: Zone 0, 1, 2, 21, 22, M1/Div 1, Div 2

Applications

Convert supported thermocouple signals into a 4-20 mA input for a PLC, controller or logger.
Scale compatible low-level DC measurements into a standard current signal.
Provide galvanic separation between the sensor input and output loop.
Condition measurements close to the sensor within a compatible DIN form B head.

Frequently Asked Questions

▶ Q: Which thermocouples are supported?
A: Types B, E, J, K, L, N, R, S, T, U, W3, W5 and LR.
▶ Q: Does it provide cold junction compensation?
A: Yes. A built-in temperature sensor provides cold junction compensation for thermocouple measurement.
▶ Q: Can it measure millivolt signals?
A: Yes. It accepts −12 to +150 mV, with a minimum measurement span of 5 mV.
▶ Q: Can I connect a PT100 sensor?
A: No. Consider the universal-input PR 5331A3B for RTD measurement.
▶ Q: Is it galvanically isolated?
A: Yes. The isolation test rating is 1.5 kVAC, with a specified working isolation voltage of 50 VAC.
▶ Q: How is it powered and configured?
A: It uses a 7.2-35 vDC two-wire loop supply. Configuration uses the PR 5909 Loop Link interface and compatible software.
▶ Q: How quickly does it respond?
A: Response time is programmable from 1–60 seconds. Sensor response also affects overall measurement speed.

5335A

5335A

PR 5335A 2-Wire Programmable Transmitters with HART 5 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 Protocol. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 8-35vDC @ 0.8W Max. 1.5kVAC Galvanic Isolation. Namur NE21, NE43 and NE89. Approvals: Zone 2, (ATEX, IECEx & INMETRO); Zone 2 – Div 2 (CSA); DNV & EAC Certification; SIL Hardware Assessment. Operating Temp: -40 to +85°C.

£361.00
Add to Basket More Info
5909

5909

USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.

£240.00
Add to Basket More Info
8421

8421

DIN Rail mounting clip for head mount transmitters

£6.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000