The PR 5332D is an intrinsically safe, head-mounted 2-wire transmitter for RTD temperature and linear resistance measurements. It converts the selected input into a 4–20 mA output for compatible monitoring and control equipment. Designed for DIN form B sensor heads, it provides a compact, configurable solution for hazardous-area installations requiring a dedicated RTD transmitter.
The 5332D accepts supported RTD sensors and linear resistance inputs. Its dedicated input design suits applications where the measurement requirement is already defined around an RTD or resistive sensor.
The sensor type and measurement range are programmable, allowing the transmitter to be matched to the connected probe and the range required by the receiving system.
RTD and resistance inputs support two-, three- and four-wire connections, with lead-resistance compensation appropriate to the selected arrangement. Four-wire operation is particularly useful where the effect of sensor cable resistance needs to be minimised.
These sensor connections are separate from the transmitter’s two-wire output loop. A four-wire RTD can therefore connect to the input while two output wires provide transmitter power and carry the measurement signal.
The configured measurement range is converted into a standard 4-20 mA current signal. This allows connection to suitable PLC inputs, indicators, controllers and data acquisition equipment.
Power is supplied through the measurement loop, avoiding a separate power connection at the transmitter. The loop supply and connected equipment must accommodate the transmitter’s operating requirements.
The 5332D is configured using PR Electronics PReset software and a compatible Loop Link interface. Programming allows the input and measurement settings to be matched to the application before installation.
This configurability allows the same transmitter model to serve different measurement ranges without requiring a separate fixed-range device for each sensor location.
The 5332D uses a non-isolated design, so selection should account for the electrical relationship between the sensor and the connected loop. Where galvanic isolation is required within the transmitter, consider a suitable isolated model such as the 5331D.
For hazardous-area use, the transmitter must form part of a compatible intrinsically safe installation. Check the relevant certification conditions, associated barrier or isolator, enclosure requirements and ambient limits together with the sensor and loop connections.
| Type | Version |
| 5332 | A: General Purpose, Zone 2, ATEX, IECEX D: Zone 0, 1, 2, 21, 22, M1/Div 1, Div 2 N: No Approvals |
Applications
Frequently Asked Questions
PR 5332D 2-Wire Programmable RTD Transmitters. Inputs: RTD (2, 3 or 4 Wire) Range -200 to +850°C; Linear Resistance – 0 to 5000Ω. Output: 4-20mA. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 7.2-30vDC @ 0.7W Max. Namur NE21, NE43. Approvals: ATEX, IECEx, FM, CSA & INMETRO. Operating Temp: -40 to +85°C.
USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.