Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR ATEX Temperature Transmitters

Home / Our Brands / PR Electronics / PR Temperature Transmitters / Head Mounted / 2-Wire ATEX Transmitters

2-Wire ATEX Transmitters

PR Electronics head-mounted 2-wire ATEX transmitters convert temperature and other supported sensor signals into a standard 4–20 mA output for industrial monitoring and control. This range includes the intrinsically safe 5331D, 5332D, 5333D and 5334B, providing different input capabilities for hazardous-area measurement. Their compact circular housings fit compatible DIN form B sensor heads, positioning signal conversion close to the sensor.

Two-Wire Signal Transmission

The same two-wire loop supplies power to the transmitter and carries the measurement signal to the receiving equipment. The configured input range is represented by the 4–20 mA output, allowing connection to suitable PLC inputs, indicators, controllers and data acquisition systems. The number of sensor wires is separate from this two-wire output arrangement. RTD connections may require two, three or four sensor wires, depending on the selected transmitter and measurement configuration.

PR 5331D – Flexible Temperature and Process Inputs

The 5331D accepts RTD, thermocouple, linear resistance and bipolar millivolt inputs. Its broad input selection suits installations requiring a configurable transmitter for several sensor types. RTD and resistance inputs support two-, three- and four-wire connections. Galvanic isolation separates the input and output circuits, with a specified isolation test voltage of 1.5 kVAC.

PR 5332D – Dedicated RTD and Resistance Measurement

The 5332D provides a dedicated option for RTD and linear resistance inputs. It supports two-, three- and four-wire sensor connections, making it suitable where a four-wire RTD arrangement is required. This model uses a non-isolated design. Selection should therefore account for the electrical arrangement of the sensor and receiving equipment, alongside the required measurement performance.

PR 5333D – RTD Measurement with Three-Wire Compensation

The 5333D converts RTD and linear resistance signals into a standard current output. It provides cable compensation for three-wire sensor connections and a programmable sensor error value. It is a practical choice for compatible PT100, PT1000 and other supported RTD installations where the sensor wiring and measurement requirements match its capabilities.

PR 5334B – Thermocouple and Millivolt Inputs

The 5334B provides an isolated option for thermocouple and bipolar millivolt measurements. Built-in cold junction compensation supports thermocouple temperature conversion, while programmable linearisation options accommodate suitable millivolt applications. Its configurable sensor error response allows the receiving system to recognise a detected measurement fault.

Configuration and Hazardous-Area Installation

These transmitters are configured using PR Electronics PReset software with the compatible Loop Link interface. Settings are selected to match the sensor, measurement range and required output behaviour. For hazardous-area use, check the individual model’s certification and installation instructions. The transmitter, sensor, enclosure and associated intrinsically safe barrier or isolator must form a compatible arrangement. Permitted zones, ambient temperatures and electrical limits depend on the selected model and approval conditions.
PR5331D Programmable ATEX Transmitter

PR5331D Programmable ATEX Transmitter

The PR 5331D is an intrinsically safe, head-mounted 2-wire transmitter that converts RTD, thermocouple, resistance and millivolt inputs into a 4–20 mA output. Designed for DIN form B sensor heads, it combines flexible input configuration with galvanic isolation and programmable sensor error indication. ATEX and IECEx approvals support hazardous-area installations, subject to certification conditions.

Explore Range
PR5332D ATEX RTD Transmitter

PR5332D ATEX RTD Transmitter

The PR 5332D is an intrinsically safe, head-mounted 2-wire transmitter that converts RTD and linear resistance inputs into a 4–20 mA output. Designed for DIN form B sensor heads, it supports two-, three- and four-wire sensor connections in a dedicated, non-isolated design. Hazardous-area approvals support use in suitably designed intrinsically safe installations, subject to certification conditions.

Explore Range
PR5333D Fast Response ATEX Transmitter

PR5333D Fast Response ATEX Transmitter

The PR 5333D is an intrinsically safe, head-mounted 2-wire transmitter that converts RTD and linear resistance inputs into a 4–20 mA output. Designed for DIN form B sensor heads, it provides three-wire lead-resistance compensation and programmable sensor error indication. It suits hazardous-area temperature and resistance measurements where its input capabilities and certification conditions match the installation.

Explore Range
PR5334B Programmable ATEX Transmitter

PR5334B Programmable ATEX Transmitter

The PR5334B is an intrinsically safe, head-mounted 2-wire transmitter that converts thermocouple and bipolar millivolt inputs into a 4-20 mA output. Designed for DIN form B sensor heads, it combines galvanic isolation with built-in cold junction compensation and programmable sensor error indication. Hazardous-area approvals support use in suitable installations, subject to certification conditions.

Explore Range

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000