EL-USB-CO Carbon Monoxide Data Loggers
The EL-USB-CO is a USB data logger that measures and stores up to 32,510 Carbon Monoxide (CO) readings over a 0 to 1000 ppm (EL-USB-CO300 0 to 300ppm) measurement range. Loggers have an integrated USB port that can be plugged directly into a PC for configuration and downloading the logged..
GSKIN DLOG Heat Flux Data Loggers
GSKIN DLOG's are a range of custom designed MSR loggers that are suitable for connecting to gSKIN Heat Flux sensors fitted with a TEG connector. The loggers have an internal memory for up to 2 million readings and have three logging modes: Autonomous; Live Operation; and Triggered. Loggers are available..
Internal Light Level Sensors
These light level sensors return a linear 0-10vDC signal representing the Lux level at the photo-diode cell. The sensors are typically used in lighting strategies to optimise energy efficiency through dimming and/or disabling of lights as required or as sensors to monitor light levels over a period of time. The..
Intrinsically Safe WindObserver Ultrasonic Anemometer
The WindObserver IS system is an Intrinsically Safe Ultrasonic Anemometers developed specifically for use in hazardous areas and offshore applications. The full system required no regular maintenance for a reliable low maintenance wind speed and direction sensor. The ATEX, IECEx & UKEX certification ensures that the wind system may be..
Legionnaires Thermometer Kit
Legionnaires' Thermometer kit can be used to monitor the temperature of both storage tanks and pipework that form part of the water system. The kits include various probes to allow you to take measurements in various locations, including immersion, surface or PTFE wire probes...
LoopView Display
LoopView is a two-wire 4-20 mA loop indicator, low power loop-powered indicator. It has a DIN connector standard EN 175301-803 (old DIN 43650 form A) male and female connectors. LoopView is powered by the current loop itself and allows to be inserted into sensors already installed in industrial facilities, to..
MiniAir20 Robust Vane Anemometers
The MiniAir20 robust vane anemometers can be used to monitor aggressive air flows with the MC 4.0 Handheld Display. The probes are available with Steel Micro and Mini and Brass Macro heads and with flow ranges of 20m/s and 40m/s. The probes are designed to be automatically recognised by the..
PA-699 Differential Air Pressure Sensor
The PA-699 is a differential air pressure sensor incorporating a proved ceramic fulcrum lever technology. They deliver calibrated, temperature-compensated sensor signals, available as standard voltage or current outputs. They are ideal for registering low air flow in air conditioning systems and for the measurement of fine pressures in environmental, laboratory..
PA-699-01
PA-699-01 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges ±30, ±50 and ±100 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-01-V
PA-699-01-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges ±30, ±50 and ±100 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-02
PA-699-02 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-30, 0-50 and 0-100 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-02-V
PA-699-02-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-30, 0-50 and 0-100 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-04
PA-699-04 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-100, 0-300 or 0-500 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-04-V
PA-699-04-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-100, 0-300 and 0-500 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-06
PA-699-06 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-500, 0-1,000 or 0-1,600 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-06-V
PA-699-06-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-500, 0-1,000 and 0-1,600 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-08
PA-699-08 Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-1,600, 0-2,500 or 0-5,000 pascals with a linear 4-20mA output from an 8-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PA-699-08-V
PA-699-08-V Differential Air Pressure Sensor in an IP65 enclosure. The Dip Switch Selectable Ranges 0-1,600, 0-2,500 and 0-5,000 pascals with a linear 0-10V output from a 13.5-33vDC power supply. 6mm Push Fit Pressure connections with Duct Fixing Kit (consisting of 2 x pitot tubes, 2m tubing and 4 x fixing..
PM-CT-M Current Transformer
The PM-CT-M range of moulded case type Current Transformers are for use with the PM-M850 kWh Meter and other suitable equipment...
Portable Handheld Flow Meter for Open Channel Flow Measurement
Portable Handheld Flow Meter for Open Channel Flow Measurement This unit utilises the MiniWater6 Mini probe and the SQ2010 portable data logger to provide a versatile and accurate portable measurement and logging device for the measurement of water flows in open channels, tanks and chambers. The measurement range is 0.02..
RMS2 Acquisition Module with Serial Communications
The RMS2 Modules are suitable for acquiring Voltage, Current, PT100 or Thermocouple inputs on a Modbus network. Each module can acquire inputs from up to 8 channels and convert the readings to a ModBus ASCII or Modbus RTU serial output. RMS2-AI collects 0-10V and 4-20mA analogue inputs, RMS2-PT will connect..
Simex SRT-94 LED Display
The SRT-94 temperature meter with inputs for PT100/500/1000 or thermocouple inputs. 4 digits, 20-millimetre LED display enables seeing of measured values from a distance. The RS-485 enables data transmission in production process monitoring systems. 2 or 4 relay (or OC) outputs make it possible to adjust the level of the..
Tinytag Plus Radio Data Logging System
The Tinytag Plus Radio Data Loggers are rugged, weatherproof units designed for use in outdoor, industrial and warehousing applications with a number of monitoring points where manually downloading individual loggers may be impractical. Units are available with thermistor,, PT100 or PT1000 temperature probes or input leads for digital inputs, voltage..
Universal Indicator N1500
High performance, universal panel mount indicator suitable for a variety of signals and sensors including RTD s, load cells, thermocouples, voltage and current. Large range of output options including relays, analogue retransmission and RS485 for connection to systems supporting the MODBUS protocol. Easy to program via front keypad, ultra bright..