5715D
PR 5715D 4 Digit Red LED display. Accepts a single 4-20mA, 0-1V, 0.2.1V, 0-10V, PT100 and Thermocouple inputs. Programmable via front keys, 2.3kVAC Galvanic isolation, 4 x Relay and Analogue 4-20mA output. Universal power supply: 21.6 to 253vAC or 19.2 to 300vDC, plus Auxiliary supply for sensors of 16-25vDC /..
5725D
Digital display, 4 digit red LED display, pulse or frequency input, P/S 21.6 - 253vAC/19.2-300vDC. 2 X relay O/P and 1 x 0/4-20mA output. Programmable via front keys...
61208
Data Downloading Software. Comes with CD-Rom, Communications and User Instructions. Suitable for PS500 Portable Gas Detector with integrated Data logger...
6185B
6185 Dual Channel Loop Powered Isolator. Galvanic isolation and 1:1 conversion of current signals within the range 0-20 mA, Response time: less than 4 ms, Accuracy 0.1% of span. Power Supply: Loop powered via the input loop, voltage drop less than 1.8V...
6315862
BM25 Alarm Transfer Kit, fitted with 25m cable..
6331A2B
2-Wire programmable transmitter with a 7.2-35vDC power supply. Dual channel unit for PT100/PT1000, Ni100 or Resistance input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6333A1B
2-Wire programmable transmitter with a 8-35vDC power supply. Dual channel unit for PT100/PT1000, Ni100 or Resistance input, producing a 4-20mA output. Can be mounted vertically or horizontally on a DIN rail...
6334A2B
2-Wire programmable transmitter with a 7.2-35vDC power supply. Dual channel unit for TC or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6337A2B
PR6337A 2-Wire programmable transmitter with HART 7 Protocol and an 8-35vDC power supply. Dual channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
6451680
RS485 Modbus RTU output option for the MX32 Gas Controller...
6513551
OLCT80D Transmitter with LCD display for flameproof remote sensor with 15m cable, sensor block available separately. The OLCT80 transmitter is supplied with 6 XP sealing plugs (4x M20 and 2 x M25), suitable cable gland kits are available separately to allow access to 2 auxiliary inputs (4-20mA or digital state),..
6798659
Battery backup-system (243 x 195 x 96 mm) for SV4B, Charger 12V - 2 A - Batteries 7 Ah..
748-524
Type T slimline, 6.2mm thick DIN rail mount thermocouple transmitter, range 0 to + 300 deg c, power supply 19.2 - 30v DC, accuracy 0.1%, output 4-20mA..
8032103012
N321 Electronic Thermostat for General Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater, with programmable delay on power up. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C, 1°C elsewhere. Power..
80321S3012
N321S Electronic Thermostat for Solar Water Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Differential controller that compares two temperature readings. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C, 1°C elsewhere.Power Supply: 100-240vAC @ 5 Watts. Dimensions:..
80321S3014
N321S Electronic Thermostat for Solar Water Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Differential controller that compares two temperature readings. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C, 1°C elsewhere.Power Supply: 12-30 vDC @ 5 Watts...
80321S3312
N321S Electronic Thermostat for Solar Water Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Differential controller that compares two temperature readings. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C, 1°C elsewhere. RS485 Modbus RTU Communications. Power Supply:..
8032201322
N322 Electronic Thermostat for Cooling/Heating Control with Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts PT100 Input (NBR 13773/97 Standard). Measurement Range: -50..
80322S3012
N322S Electronic Thermostat for Solar Water Heating Control with a SPDT Relay Output (Max 250vAC @ 16A) and a SPST Relay (Max 250vAC @ 3A2. Differential controller that compares two temperature readings. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C,..
80322S3312
N322S Electronic Thermostat for Solar Water Heating Control with a SPDT Relay Output (Max 250vAC @ 16A) and a SPST Relay (Max 250vAC @ 3A2. Differential controller that compares two temperature readings. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C,..
80322S3314
N322S Electronic Thermostat for Solar Water Heating Control with a SPDT Relay Output (Max 250vAC @ 16A) and a SPST Relay (Max 250vAC @ 3A2. Differential controller that compares two temperature readings. Accepts NTC Thermistor Input. Measurement Range: -50 to +120°C (-58 to 248F), Accuracy 0.6°C between -19.9 to 99.9°C,..
80322T1022
N322T Electronic Thermostat for heating and refrigeration purposes with built-in timer. Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts PT100 Input (NBR 13773/97..
80322T3022
N322 Electronic Thermostat for heating and refrigeration purposes with built-in timer. Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts NTC Thermistor Input. Measurement..
80322T4024
N322T Electronic Thermostat for heating and refrigeration purposes with built-in timer. Single SPDT Relay Output, Max 250vAC @ 16A. Direct Switching of compressor or electrical heater with simple ON/OFF control and a second SPST-NO Relay (Max 250vAC @ 3A) suitable for additional control or alarm. Accepts Thermocouple (Type J, K..