WindUltra Ultrasonic Wind Speed and Direction Sensor
The WindUltra is a compact ultrasonic anemometer providing wind speed and direction data into a serial RS485, Modbus, NMEA and SDI-12 output.The WindUltra is a small, lightweight (0.27kg) sensor and covers a wind speed range up to 75m/s. The WindUltra sensor locks into a 1" or 2" Pole Mounting..
WISENS-TD Temperature & Depth Logger
The WISENS-TD Temperature & Depth Logger is an Underwater Logger that monitors water depth and temperature. Depth Range: down to 6,000m; Temperature: -2 to +35°C. Sampling Rate from 1 second to 99 hours. Dimensions: 220 x 45mm Diameter. Weight: 361g (Included 100g for battery). Logger is not vented to account..
WISENS-WAVE
The WiSens-Wave is an Underwater Logger that monitors wave height based on sub-surface water depth/hydrostatic pressure fluctuations. Depth Range: 30m; Temperature: -2 to +35°C. Sampling Rate from 1 to 16Hz. Dimensions: 220 x 45mm Diameter. Weight: 361g (Included 100g for battery). Logger should be mounted in a fixed or stable..
WLM4 – Four Channel Water Leak Detection Module
The WLM4 Water Leak Detection Module has 4 input channels with zone indication and 1 common output with fault indication. DIN Rail or wall mount options. The WLM4 can be used with a combination of water detection sensors...
WLM4-24
4 Channel Water Leak Detection Module with built in sounder and changeover relay. Power Supply 24vDC ±10%. LED indication for input channels, supply detection and heater activation. Output 230vAC @ 10A Volt-free Changeover Contact. Dimensions: 70 x 60 x 90mm...
WMO-869S-L
WMO-800S Series, High Speed Modem for Industrial Wireless Applications. Power supply 10-30vDC, frequency range 869.525MHz with a 5mW transmitter power. Single serial port for RS485 or RS232 connections...
WP600-RAMP
WP Series - Platform Ramp in Mild Steel for Weighing platform (600 x 600mm). Fits to smallest side. Priced per ramp...
WPH-N-65
WPH Type Woltmann Helix Hot Water Meter. Pipe diameter 65mm with PN16 flanged connections, flow range: Qmin 1.0 m3/hr; Qn 25m3/hr; Qmax 120m3/hr. Epoxy coated cast Iron body suitable for up to water up to 90 C. Additional pulse output options from 100 to 1,000 Ltr/pulse are available at the..
WPI-SDC-65
WPI-SDC Irrigation Water Flowmeter. Pipe diameter DN65 with standard PN16 flanges. Flow range Q1 3.15m³/h, Q2 5.04m³/h, Q3 63m³/h and Q4 78.75m³/h. IP68 Epoxy Coated Iron body with replaceable copper can mechanism. Additional pulse output options from 0.1 to 1 m³/pulse are available at the time of order. (Please order..
WTUNNEL-3001
wTunnel Transparent Wireless Tunnel Device. Power supply 10-30vDC, operating temperature -5 to +65 deg C, DIN rail mounting. 1 x RS232/RS485/USB serial port, 2 Analogue Inputs (0-10V & 4-20mA), 2 Digital Inputs and 2 Digital Outputs. 2.4GHZ Zigbee radio communications, maximum range 2KM line of sight...
Li-Ion Rechargeable Battery Peli Case Kit
Tracer Li-Ion Rechargeable Battery Packs in Portable Carry Case Kits offer a lightweight solution for remote power. These kits are very popular with professionals due to how easy they are to carry and install, plus there versatile power supply options. Each kit includes 2 USB ports, one 12V accessory socket,..
8801801615
WL420 Submersible Hydrostatic Level Transmitter. Depth Range 1.6mH2O. 2-Wire Loop Powered 4-20mA Output with a 12-36vDC Power Supply. 15m Polyurethane (PUR) Cable with Ventilation Tube. Over-Pressure 300% FS, Burst Pressure 600% FS. Stainless Steel Sensor with 105mm Body Length and 26.5mm Diameter...
HiTemp140-TS(FLUSH)
HiTemp140-TS(FLUSH) Thermal Shield..
HiTemp140-TS(VENTED)
HiTemp140-TS(FLUSH) Thermal Shield..
Keller LEO2Ei Digital Manometer
The Keller LEO2Ei is a hazardous area approved digital manometer and available from stock. The LEO2EI is a highly accurate, battery-powered digital manometer designed for precise pressure measurement. The gauge uses a piezoresistive pressure cell, ensuring accuracy of 0.1% full scale, it also features peak hold and selectable pressure units...
LEO2-O2 Digital Manometer Suitable for O2 Applications
LEO2-O2 Digital Manometers specifically designed LEO2 for Oxygen pressure monitoring. The diaphragm oil is Galden HT720 and is suitable for use up to 200 Bar at 60°C or Fomblin M100 oil can also be used up to 330 Bar. Diaphragm and pressure ports must be kept clean of any other..
LEO3-10BAR-1/4BSP
LEO3 Digital Manometer with programmable 4-20mA output and RS485 communications. The LEO 3 displays both the current pressure reading and the output signal value. Pressure range -1 to 10 Bar, accuracy of 0.1%. Pressure connection ¼" BSP male connection, operating temperature 0 to 50°C and IP65 casing. Manometer is loop..
1-Wire Compact Temperature and Humidity Sensor
The TSH202B is a 1-Wire Compact Temperature and Humidity Sensor designed for accurate humidity and temperature monitoring in a discrete black housing. This sensor integrates a capacitive humidity and band-gap temperature sensors with a 12-bit ADC for quality data and fast response, and supporting multiple sensors via a unique serial..
1000 Series Squirrel
The basic Squirrel data logger is small and portable and consists of the CPU and battery pack. The CPU contains the processor, memory, power connector, display, RS232 serial connection, a pulse input, an 8 bit digital signal input and output connector...
271-303
3003 Dry-Well Calibrator. Suitable for providing a portable heat source for testing temperature probes over a temperature range of +33 to +300°C with a resolution of 0.1°C. Power supply 230vAC. Dimensions 57 x 125 x 158mm, weight 900g. Suitable for probe diameters of 4.76 and 12.7mm. Unit comes supplied with..
400.0303
MC 4.0 ManoAir Manometer Touchscreen Display and 4,000mAh Lithium Polymer Battery. Range ±2,000Pa. The MC 4.0 can measure absolute or differential pressures, filter and pitot tubes for ventiliation ducts. Measurement Range ±2000Pa. Resolution: 1Pa, Accuracy: <100 Pa ± 3 Pa + ±0.10%FS >100 Pa ±10 Pa + ±0.10%FS. 3.2" TFT..
4131 Universal Trip Amplifier
PR 4131 Universal signal conditioning module, detachable front programming unit 4510, can be configured for all types of standard industrial measuring signals such as RTD, TC, Ohm, potentiometer, mA and V. 2 relays , universal power supply of 21.6 - 253 VAC and 19.2 - 300 VDC..
4225C
4225C Programmable Universal f/f & f/I Converter. Outputs: 1 Analogue (Current: 0-20, 4-20, ±10mA, or ±20mA; Voltage: 0-5, 1-5, 0-10, 2-10, ±5, ±10vDC) and 1 Frequency Output (Frequency (0.001-100kHz: NPN/PNP/Push-Pull output: 5-24vDC@ 130mA). Power Supply: 21.6-253vAC or 19.2-300vDC..
433.20.11.04.62.10.U
Programmable pressure transmitter, 316L s/s housing and diaphragm, viton seals. Range 0 to 1000barG [programmable between 250 to 1000 bar]. 1/4 G pressure connection. Electrical connection - Binder 723 7 pin. Output RS485, 4 -20mA . Accuracy ±0.25%. Temp range 0 to 70°C...