SW10026.1
Brass Nickeled Pitot Tube for measuring static and dynamic pressure in air flows. 8mm diameter tube with 800mm probe length. Suitable for temperatures up to 350°C..
TX2-1G011
Tango TX2 Two Gas Detector for Carbon Monoxide (CO), Range 0-1000 ppm in 1ppm increments & Carbon Monoxide (CO/H2 Low), Range 0-1,000 ppm in 1ppm increments (Two electrodes and a special catalyst with a lower sensitivity to Hydrogen). Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for..
95.0273
ManoAir500 universal high temperature probe, range -20 to 600°C, accuracy ±1°C, head dim 3 x 230mm, shaft diameter 22mm access opening 4 mm, probe length 350mm, with 1.8 metres of cable...
95.0275
ThermoAir3, Hot Wire Directional anemometer probe. Range 0.015 - 1 m/s, accuracy +/-1% of full scale, 1.5% of reading. Probe diameter sensing head 8mm, shaft 15mm, probe length 300mm, 1.5 metres of cable..
95.0277
ThermoAir3, Hot Wire Directional anemometer probe. Range 0.015 - 5 m/s, accuracy +/-0.2% of full scale, 1.5% of reading. Probe diameter sensing head 8mm, shaft 15mm, probe length 300mm, 1.5 metres of cable..
95.0279
ThermoAir3, Hot Wire Omni-Directional anemometer probe. Range 0.015 - 1 m/s, accuracy +/-1% of full scale, 1.5% of reading. Probe diameter protection basket 110mm, sensing head 8mm, shaft 15mm, probe length 300mm, 1.5 metres of cable..
95.0281
ThermoAir3, Hot Wire Omni-Directional anemometer probe. Range 0.015 - 5 m/s, accuracy +/-0.2% of full scale, 1.5% of reading. Probe diameter protection basket 110mm, sensing head 8mm, shaft 15mm, probe length 300mm, 1.5 metres of cable..
SW10026.8
Brass Nickeled Pitot Tube for measuring static and dynamic pressure in air flows. 10mm diameter tube with 1,000mm probe length. Suitable for temperatures up to 350°C..
TX2-24011
Tango TX2 Two Gas Detector for Hydrogen Sulphide (H2S) range 0-200 ppm in 0.1ppm increments & Nitrogen Dioxide (NO2), Range 0-150 ppm in 0.1ppm increments. Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for 3 months at 10 second interval plus 60 alarm events. The replaceable internal..
SW10026.7
Brass Nickeled Pitot Tube for measuring static and dynamic pressure in air flows. 10mm diameter tube with 1,500mm probe length. Suitable for temperatures up to 350°C..
TX2-25011
Tango TX2 Two Gas Detector for Hydrogen Sulphide (H2S) range 0-200 ppm in 0.1ppm increments & Sulphur Dioxide (SO2), Range 0-150 ppm in 0.1ppm increments. Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for 3 months at 10 second interval plus 60 alarm events. The replaceable internal..
TX2-2G011
Tango TX2 Two Gas Detector for Hydrogen Sulphide (H2S) range 0-200 ppm in 0.1ppm increments & Carbon Monoxide (CO/H2 Low), Range 0-1,000 ppm in 1ppm increments (Two electrodes and a special catalyst with a lower sensitivity to Hydrogen). Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for..
TX2-45011
Tango TX2 Two Gas Detector for Nitrogen Dioxide (NO2) range 0-150 ppm in 0.1ppm increments & Sulphur Dioxide (SO2), Range 0-150 ppm in 0.1ppm increments. Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for 3 months at 10 second interval plus 60 alarm events. The replaceable internal..
95.0400
Replacement MiniAir Mini snap head with an air velocity range of 20m/s with a Steel turbine. Sensing head 22mm diameter x 28mm. Suitable for use with the following MiniAir probe part numbers: MIEX202252, MIEX06252, MIEX64252, 95.0378, 93.0864...
95.0401
Replacement MiniAir Mini snap head with an air velocity range of 40 m/s with a Steel turbine. Sensing head 22mm diameter x 28mm. Suitable for use with the following MiniAir probe part numbers: MIEX202254, MIEX06254, MIEX64254, 95.0379, 93.0867...
95.0402
Replacement MiniAir Macro snap head with an air velocity range of 20 m/s with a Steel turbine. Sensing head 85mm diameter x 80mm. Suitable for use with the following MiniAir probe part numbers: MIEX202262, MIEX06262, MIEX64262, 95.0380, 93.1044...
95.0403
Replacement MiniAir Macro snap head with an air velocity range of 40 m/s with a Steel turbine. Sensing head 85mm diameter x 80mm. Suitable for use with the following MiniAir probe part numbers: MIEX202264, MIEX06264, MIEX64264...
TX2-4G011
Tango TX2 Two Gas Detector for Nitrogen Dioxide (NO2) range 0-150 ppm in 0.1ppm increments & Carbon Monoxide (CO/H2 Low), Range 0-1,000 ppm in 1ppm increments (Two electrodes and a special catalyst with a lower sensitivity to Hydrogen). Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for..
95.2032
MiniAirJunior Mini, EEX probe anemometer, air velocity range 0.3 - 20 m/s, accuracy +/- 1% of full scale, 3% of reading, head dim 22 x 28mm, access opening 35 mm, probe length 175mm, with 1.5 metres of cable. vane and Handle in steel..
96.006
ThermoAir3 Thermoelectric Anemometer display unit, with 4 digit LCD display. Suitable for measuring directional and omnidirectional flow velocity, temperature and humidity readings depending on attached probe. 0 to 1 V output for Flow or humidity readings and a 10mV/ C for temperature (Zero at -30 C), interval 0.5secs). Dimensions 80mm..
TX2-5G011
Tango TX2 Two Gas Detector for Sulphur Dioxide (SO2) range 0-150 ppm in 0.1ppm increments & Carbon Monoxide (CO/H2 Low), Range 0-1,000 ppm in 1ppm increments (Two electrodes and a special catalyst with a lower sensitivity to Hydrogen). Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for..
97.0269
ThermoAir 64 Thermal-Electric Uni-Directional Anemometer. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. Air velocity range: 0-1m/s with a 2 second attenuated 4-20mA output. Accuracy ±1.5% of full scale. Power supply 15-26vDC. The sensor can be plugged into the measuring transducer housing or used separately from it. Transducer..
97.0272
ThermoAir 64 Thermal-Electric Uni-Directional Anemometer. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. Air velocity range: 0-1m/s with a 2 second attenuated 4-20mA output. Accuracy ±1.5% of full scale. Power supply 15-26vDC. The sensor can be plugged into the measuring transducer housing or used separately from it. Transducer..
97.0273
ThermoAir 64 Thermal-Electric Omni-directional Anemometer. Sensing head 110mm diameter, handle 15mm diameter, probe length 310mm. Air velocity range: 0-1m/s with a 2 second attenuated 4-20mA output. Accuracy ±1.5% of full scale. Power supply 15-26vDC. The sensor can be plugged into the measuring transducer housing or used separately from it. Transducer..