OMEGA-PULSE-OPTION-K=100K
Pulse output option for Omega water meters 100,000Ltr/pulse..
QI-100/5-1
Current Transformer 100A, DIN rail mounting, 20mm hole, 5A Secondary..
RTR507B
RTR507B Remote Data Logger with high precision temperature and humidity sensor, Ref SHB-3101. Temperature Range: -25 to +70°C, Accuracy ±0.3°C (0 to +55°C), Resolution 0.1°C. Humidity Range: 0-99%RH, Accuracy ±2.5%RH (at 25°C), Resolution 0.1%RH. Response Time 7 mins (t90% in air). Internal Memory 16,000 Readings (8,000 Data Sets), Logging Interval:..
TX2-1G021
Tango TX2 Two Gas Detector for Carbon Monoxide (CO), Range 0-1000 ppm in 1ppm increments & Carbon Monoxide (CO/H2 Low), Range 0-1,000 ppm in 1ppm increments (Two electrodes and a special catalyst with a lower sensitivity to Hydrogen). Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for..
WC30CO2C
CTX 300 Fixed Gas Detector. Infrared Carbon Dioxide (CO2) Cell, Range 0-100%. Accuracy ±2% (% at PA full scale), response time less than 20 seconds. Operating temperature -40 to +50°C. Life span 60 months...
17134503
Replacement Nitrogen Dioxide (NO2) Sensor for Ventis MX4 Gas Detector..
LEO2-700BAR-1/4BSP
LEO 2 Digital Manometer with digital display. Pressure range 0 to 700 Bar with 200mBar resolution and 0.1%FS accuracy. Peak reading function and selectable engineering units. Internal battery for up to 1,000 hours continuous operation. Pressure connection: Stainless Steel 7/16"-20 UNF male connection with ¼" BSP swivel adapter...
OLCT10-005
OLCT10 Fixed Gas Detector for Propane (C3H8), Range 0-100% LEL. Output: 4-20mA. Response Time:<10 Seconds. Power supply: 15-30vDC, consumption 100mA max. Operating temperature: -10 to +60°C. Life span: 4 years. Plastic housing, 118 x 157 x 60mm, IP65. ATEX Certification: II 3G, Ex nA IIC T4...
QI-150/5-1
Current Transformer 150A, DIN rail mounting, 20mm hole, 5A Secondary..
TX2-24021
Tango TX2 Two Gas Detector for Hydrogen Sulphide (H2S) range 0-200 ppm in 0.1ppm increments & Nitrogen Dioxide (NO2), Range 0-150 ppm in 0.1ppm increments. Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for 3 months at 10 second interval plus 60 alarm events. The replaceable internal..
17143595
Replacement Sulphur Dioxide (SO2) Sensor for Ventis MX4 Gas Detector..
BLUELINK-LEVELINE
BlueLink-Leveline Bluetooth device for connectivity to the Leveline range of water quality probes. Mobile phone app available free from Google Play Store...
BLUELINK-PROBE
BlueLink-Probe Bluetooth device for connectivity to the Aquaprobe & PRO range of water quality probes. Mobile phone app available free from Google Play Store...
CabU_30m_RJ11
1-Wire interface cable with RJ11 connectors. Cable length 30m, ideal for connecting a single Teracom Ethernet or GSM/LTE I/O module to one of the 1-Wire units with RJ11 connectors...
FT9.3/020
External Plug-in Temperature Sensor for MSR Data Loggers, IP60 Rated. Temperature Range -40 to +125°C, Accuracy ±0.2°C (-10 to +50°C) & ±1°C (-40 to +125°C). 0.2m black cable suitable for use up to +75°C (white cable up to +200°C available on request). A maximum of 5 pre-calibrated sensors can be..
QI-200/5-2
Current Transformer 200A, DIN rail mounting, 23mm hole, 5A Secondary..
TX2-25021
Tango TX2 Two Gas Detector for Hydrogen Sulphide (H2S) range 0-200 ppm in 0.1ppm increments & Sulphur Dioxide (SO2), Range 0-150 ppm in 0.1ppm increments. Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for 3 months at 10 second interval plus 60 alarm events. The replaceable internal..
35253A
Terminal Block Cable (DB9M to tinned leads 1.2M.)..
FT9.3/100
External Plug-in Temperature Sensor for MSR Data Loggers, IP60 Rated. Temperature Range -40 to +125°C, Accuracy ±0.2°C (-10 to +50°C) & ±1°C (-40 to +125°C). 1.0m black cable suitable for use up to +75°C (white cable up to +200°C available on request). A maximum of 5 pre-calibrated sensors can be..
QI-300/5-2
Current Transformer 300A, DIN rail mounting, 23mm hole, 5A Secondary..
TX2-2G021
Tango TX2 Two Gas Detector for Hydrogen Sulphide (H2S) range 0-200 ppm in 0.1ppm increments & Carbon Monoxide (CO/H2 Low), Range 0-1,000 ppm in 1ppm increments (Two electrodes and a special catalyst with a lower sensitivity to Hydrogen). Alarms: Audible 100dB, vibration and three strobe-emitting visual LEDs. Internal logging for..
353700
Large Side Mounting Plate with fittings for 2 x CHP1/SHP1 or 1 x CHP1/SHP1 and sun sensor. Diameter 203mm x 6mm thick..
0353705
Shading Ball Assembly. Including 3 shading balls on rods, rear mounting plate for 3 ventilated radiometers and 2 large side plates for up to 3 Pyrheliometers and 1 Sun sensor. Adaptor kit required for unventilated radiometers...
353706
Adapter Kit. To fit one radiometer on rear plate without CVF4 Ventilation Unit..