2000-NIT
AP-2000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 2000-NIT is designed for use with the AP-2000 Aquaprobe sensor with pH probe...
2000-TURB
AP-2000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU...
224-617
Spare remote probe for the 6100 series Thermo-hygrometer. The probe is fully interchangeable and can be easily replaced. it comes with cable and a 6-pin Lumberg connector. Probe will only work with 6100 Instrument with serial numbers later than D20120375, and 6102 Instruments with serial numbers later than D20100842..
224-618
Spare replacement sintered remote probe for the 6100 series Thermo-hygrometer. The sintered probe prevent dust contamination of the probe in more harsh environments. The probe is fully interchangeable and can be easily replaced. it comes with cable and a 6-pin Lumberg connector for connection to the 6100 Series Therma-Hygrometer. Probe..
25000495
LUXUS Compact Camera Mounting Bracket. Manufactured from high grade HDPE and AISI 316 stainless steel, LUXUS brackets are rated for use on 4000 metres water depth...
25000497
LUXUS Camera Mounting Bracket. Manufactured from high grade HDPE and AISI 316 stainless steel, LUXUS brackets are rated for use on 4000 metres water depth...
271-200
The MicroCal 2 K-Type Thermocouple Simulator helps to ensure the frequent checking of thermometer accuracies is a routine operation. Designed to simulate a chosen temperature to test K-Type Thermocouple thermometers. It has 12 adjustable temperature points (-20, -10, 0, +10, +30, +50, +100, +195, +250, +500, +800 and +1000°C). Battery..
3111
3111 Slim Series Isolated Thermocouple Converter suitable for conversion of K and J Type Thermocouple input to a 0/4-20mA, 0/1-5V or 0/2-10V output signal. Response time: less than 30ms or 300ms, Accuracy better than 0.05% of selected range, or 0.5 C. Power Supply: 24vDC +/-30%. 6mm Slimline housing. Units are..
3331
3331 Slim Series Isolated, Loop-powered, Temperature Converter suitable for conversion of K and J Type Thermocouple or PT100 input to an isolated passive 4-20mA or 20-4mA output signal. Response time: less than 30ms or 300ms, Accuracy better than 0.05% of selected range, or 0.5 C. 6mm Slimline housing. Units are..
400.0410
ThermoAir 4 Directional Thermal-Electric Directional Anemometer with Barometric Pressure Compensation. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. The required diameter of the retraction opening for the probe is 9mm. Air Velocity Range: 0.015-1m/s. Accuracy ±1.0% of full scale. The sensor can be used at temperatures from..
400.0900
Stainless Steel Temperature and Humidity Probe for Lab 4.0. Temperature Range -40 to 85°C, Accuracy ±0.1°C. Humidity Range 0 to 100%RH, Accuracy ±1.5% at 10-90%RH...
5000-AMM
AP-5000 Ammonium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-8,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Probe will also monitor Ammonia when used in combination with pH and temperature readings on the AP-5000 Aquaprobe sensor..
5000-CAL
AP-5000 Calcium Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-1,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 5000-CAL is designed for use with the AP-5000 Aquaprobe sensor with pH probe...
5000-CHL
AP-5000 Chloride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-19,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). The 5000-CHL is designed for use with the AP-5000 Aquaprobe sensor..
5000-DG
Drill guide for all 5200 and 6200 series flow meters...
5000-FLU
AP-5000 Fluoride Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.05 ppm. The 5000-FLU is designed for use with the AP-5000 Aquaprobe sensor with pH probe. Readings may be affected by Hydroxide ions...
5000-NIT
AP-5000 Nitrate Electrode with 2 Auto-Range scales 0-99.9 mg/L (ppm) or 100-29,999 mg/L (ppm). Accuracy ±10% of readings or 2ppm (whichever is greater). Minimum Level of Detection 0.5 ppm. The 5000-NIT is designed for use with the AP-5000 Aquaprobe sensor with pH probe...
5000-TURB
AP-5000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU...
5104B–A
PR5104B Single Channel Repeater/Power Supply suitable for hazardous area applications. Single Channel, ATEX II (1) GD, with 2 x 4-20mA inputs, 24-230 vAC/DC power supply, provides 18V loop power to transmitters via zener barrier and 2 x isolated 4-20mA O/P s to external devices...
5114B1A
Programmable Transmitter, 1 Channel, ATEX II (1) GD, RTD, TC, mV, R, 24...230 VAC/DC..
5131B1A
Single channel 2-wire programmable ATEX transmitter with a 7.5-35vDC power supply. Suitable for RTD, TC, R and mV Input and 4-20mA output...
60990002
½" BSP Inlet and Outlet Pipe Set for F.Core Flow Sensor...
610-12
Replacement Membrane Kit for Dissolved Oxygen Sensors..
6185 Loop Powered Isolator
The 6185 is a loop powered isolator suitable for the galvanic separation of analogue current signals with a straight 1:1 conversion of 0-20mA inputs. The 6185 is available in single, dual and four channel versions with a slimline 3185 series available in single and dual channel versions, all with no..