omni instruments | sensors and data acquisition equipment

Sales & Technical Support

Edit Content

OLCT10 Gas Detectors for Refrigerant and Toxic Gases

The OLCT10 TOX gas detectors are designed for commercial applications for the detection of refrigerant gases and the presence of exhaust gases from combustion in ambient air. These detectors are ideal for the continuous monitoring of toxic gases in car parks, boiler rooms and plant rooms for shops and warehouses. Up to 5 OLCT10 TOX units can be networked in a single line to cover the same gas. These detectors provide a 4-20mA output that can be combined with the MX16 controller unit to provide a low cost gas monitoring system.

Need help finding the right product?

Downloads

OLC(T)10 Gas Detectors

Description

Features

  • Electrochemical and semiconductor sensors
  • 4-20 mA output signal
  • Dust and humidity resistant (IP65)
  • Fast and accurate response
  • ATEX approval for use in hazardous areas (CO, NO and NO2)
  • Refrigerant (Freon) detectors for safe areas only.
  • Up to 5 detectors on same line (CO, NO, NO2)

Applications

  • Fridge, freezer and air conditioning plant rooms
  • Multi-storey and underground car parks
  • Temperature controlled warehouses
  • Refrigerant storage
  • Boiler and furnace rooms.

Specifications

Gas CO NO NO2 Refrigerants
Sensor Type Electrochemical Sensor Semi-Conductor
Range 0-300ppm 0-100ppm 0-30ppm 0-2000ppm
Signal Output 4-20mA
Power Supply 15 to 30vDC
Power Consumption 30mA 100mA
Dimensions Width 118 x Height 157 x Depth 60mm
Material Plastic
Protection Rating IP65
Estimated Lifetime >24 Months >36 Months >24 Months >24 Months
Hazardous Area Certification II 3G / Ex nA IIC T4 Safe Area Only

Product

Ref

Price

Product Description

OLCT10-204

£335.00

OLCT10 Fixed Gas Detector for Carbon Monoxide (CO). Range 0-300ppm. Output 4-20mA. Power supply 15-30vDC, consumption 30mA max. Operating temperature -20 to +55°C. Life span >24 months. Response time less than 30 second (T90). Plastic housing, 118 x 126 x 63mm, IP65.

OLCT10-216

£400.00

OLCT10 Fixed Gas Detector for Nitrogen Monoxide (NO). Range 0-100ppm. Output 4-20mA. Power supply 15-30vDC, consumption 30mA max. Operating temperature -20 to +55°C. Life span >36 months. Response time less than 120 second (T90). Plastic housing, 118 x 126 x 63mm, IP65.

OLCT10-220

£400.00

OLCT10 Fixed Gas Detector for Nitrogen Dioxide (NO2). Range 0-30ppm. Output 4-20mA. Power supply 15-30vDC, consumption 30mA max. Operating temperature -10 to +50°C. Life span 24 months. Response time less than 120 second (T90). Plastic housing, 118 x 157 x 60mm, IP65. OLCT10 Fixed Gas Detector for Nitrogen Dioxide (NO2). Range 0-30ppm. Output 4-20mA. Power supply 15-30vDC, consumption 30mA max. Operating temperature -20 to +55°C. Life span >24 months. Response time less than 90 second (T90). Plastic housing, 118 x 126 x 63mm, IP65.

OLCT10-500

£305.00

OLCT10 Fixed Gas Detector for R12 Refrigerant Gas Range 0-1% volume. Output 4-20mA. Power supply 15-30vDC, consumption 100mA max. Operating temperature -10 to +60°C. Life span 24 months. Plastic housing, 118 x 157 x 60mm, IP65.

OLCT10-501

£305.00

OLCT10 Fixed Gas Detector for R22 Refrigerant Gas Range 0-2000ppm. Output 4-20mA. Power supply 15-30vDC, consumption 100mA max. Operating temperature -10 to +60°C. Life span 24 months. Plastic housing, 118 x 157 x 60mm, IP65.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Enquire now