omni instruments | sensors and data acquisition equipment

Sales & Technical Support

Edit Content

CabU_1m_RJ11

1-Wire interface cable with RJ11 connectors. Cable length 1m. The CabU_1m_RJ11 cable can also be used to add one of the 1-Wire sensors with screwless terminals to a network by using the SPL2_RJ11 cable.

£6.23

Need help finding the right product?

Description

Many Teracom 1-Wire devices are designed to facilitate a Linear Daisy-Chained Network Topology using integrated RJ11 connectors. See table below.

Part Number Description
TST103 Digital Temperature Sensor
TSH206v3 Digital Temperature and Humidity Sensor
TST200 PT100 Transmitter
TSA200 Current Loop Transmitter
TSV200-60i 60V Voltage Input Transmitter
TSC200-15 Galvanic Isolated Current Sensor
TSL200 Ambient Light Sensor
TSP200 Barometric Pressure Sensor

Teracom suggests a total cable length of up to 30 meters using UTP/FTP cables. Using the CabU_1m_RJ11 cables between these devices is well within this guideline and can help maintain signal integrity over the 1-Wire bus, particularly as RJ11 connectors are well-suited for low-speed data connections like those used in 1-Wire networks. This configuration allows for a simple and effective method to expand the 1-Wire network linearly.

On a single network with Teracom 1-Wire devices, the practical limit is often dictated by the specific controller or module being used. Many Teracom Ethernet and GSM/LTE I/O modules, such as the TCW241, TCG140-4, TCW240B, and TCW210-TH, are designed to support up to 8 Teracom 1-Wire sensors. Some older or smaller controllers, like the TCG120 and TCW122B-CM, specify a limit of up to 4 1-Wire sensors.

Pinout of RJ-11 Connectors

Pin Description UTP Wire Colour
1 1-Wire Ground White/Brown
2 1-Wire Ground White/Green
3 1-Wire Data Green
4 1-Wire Ground White/Orange
5 1-Wire +VDD Orange
6 1-Wire +VDD Brown

1-Wire Network Linear Topology

Using the 1m, or 3m, RJ-11 cables with the 1-Wire Sensors and Transmitters with dual RJ-11 connectors allow you to create a Daisy-Chained Linear Topology. The max cable length, from the Master device to the Slave device at the further point, should be less than 30m. With the limitations of the Teracom Ethernet and GSM/LTE I/O modules of a maximum of 4 or 8 1-Wire sensors, you would not exceed this, even with the 3m cables.

 

1-Wire Network Stubbed Topology

Using the 1m, or 3m, RJ-11 cables with a separate 1-Wire Network would allow you to create a Stubbed Network topology. This can be achieve by using the SPL2_RJ11 cable to the 1m, or 3m RJ-11 cables. The stubs can then be connected to one of the 1-Wire sensors with screwless terminals to a network with RJ-11 sensors. As each Stub of 3m would count 6m as the cable length, the CabU_1m_RJ11 would help prevent the total length exceeding the 30m maximum.

CabU_3m_RJ11

£7.60

1-Wire interface cable with RJ11 connectors. Cable length 3m. The CabU_3m_RJ11 cable can also be used to add one of the 1-Wire sensors with screwless terminals to a network by using the SPL2_RJ11 cable.

CabU_30m_RJ11

£24.68

1-Wire interface cable with RJ11 connectors. Cable length 30m, ideal for connecting a single Teracom Ethernet or GSM/LTE I/O module to one of the 1-Wire units with RJ11 connectors.

SPL2_RJ11

£15.08

The SPL2_RJ11 cable can be used to connect the RJ11 connector to a wired network, or connect one of the 1-Wire sensor with screwless terminals to the RJ11 cables    

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Enquire now