Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR Electronics

PR4114 universal transmitter converting temperature or position sensor signals for a control system.
Home / Our Brands / PR Electronics / Multi-Function Devices / Universal Signal Transmitters & Calculators / PR4114 Universal Transmitter

PR4114 Universal Transmitter

Universal Signal Conversion

The PR4114 universal transmitter converts temperature and process inputs into standard analogue signals for a PLC, controller or data acquisition system. Its configurable input accepts RTD, thermocouple, resistance, potentiometer, current and voltage signals.

Selectable current and voltage outputs allow the measurement to be matched to the receiving equipment, providing a flexible interface between field sensors and control systems.

Temperature and Position Measurement

The PR4114 provides linearised temperature measurement from compatible RTD sensors and thermocouples. Resistance and potentiometer inputs also support conversion of suitable position measurements into an analogue output.

An integrated transmitter supply allows the module to power a compatible two-wire transmitter while isolating its measurement signal.

Isolated DIN Rail Installation

Three-port galvanic isolation separates the input, output and power supply. The universal supply accepts 21.6–253vAC or 19.2–300vDC.

The PR4114 provides configurable signal conditioning for installations requiring analogue measurement transmission between sensors and receiving equipment.

Programming and Monitoring the PR4114

With the PR4114, the selected interface provides access to input type, measurement range and analogue output settings. Local indication helps operators check the measured value, while signal simulation supports commissioning of the receiving equipment. Choose the 4510 for local setup and display, the 4511 to make process information available over Modbus RTU, or the 4512 for Bluetooth configuration and recording measurement trends.

Applications

Using the newly expanded support for Copper RTD sensors to track internal coil temperatures and prevent overheating.
Converting linear resistance variations from potentiometers on solenoids or butterfly valves into standard 4-20mA control signals.
Serving as a reliable signal isolator in process loops requiring high functional safety and SFF/PFD data compliance.
Linearising signals from Thermocouples (Types B, K, J, R, S, etc.) and RTDs (PT100, Ni100) for high-accuracy process control.
Providing a >16V supply to power field-mounted 2-wire transmitters while providing 2.3kV galvanic separation to protect PLC inputs.
Utilising the 4512 Bluetooth interface to perform "on-site" analysis of real-time process data on mobile devices without breaking the loop.

Frequently Asked Questions

â–¶ Q: Which inputs does the PR 4114 accept?
A: The PR 4114 accepts supported RTDs, thermocouples, linear resistance, potentiometers, current and DC voltage signals. The input type and measurement range are selected during configuration.
▶ Q: Can it convert a PT100 signal to 4–20 mA?
A: Yes. It can linearise a Pt100 measurement and provide a 4–20 mA output scaled to the configured temperature range.
▶ Q: Can it provide a 0–10 V output?
A: Yes. The PR 4114 supports configurable current and voltage outputs, including 0–20 mA, 4–20 mA and 0–10 V.
â–¶ Q: How is the PR 4114 configured?
A: Configuration uses a compatible PR 4500-series detachable display or communication interface. Input selection, scaling and other operating parameters are set electronically, without opening the housing to adjust DIP switches.
â–¶ Q: Does the programming display have to remain fitted?
A: No. The transmitter retains its configuration and continues operating when the detachable programming display is removed. Leave a suitable display fitted when local measurement readout is required.
â–¶ Q: What is the difference between the PR 4114 and PR 4116?
A: The PR 4114 provides analogue current or voltage output. The PR 4116 adds two relay outputs for functions such as threshold alarms, making it suitable when analogue transmission and local relay switching are both needed.

4114

4114

PR 4114 Programmable Universal Transmitter with universal AC or DC power supply. Input: RTD; Thermocouples; Ohm; potentiometers; mA; V. Output: 0(4)-20mA; 0-10V. Galvanic isolation of inputs and outputs. Power supply 21.6 - 253vAC or 19.2 - 300vDC plus 16-25vDC auxiliary supply. DIN Rail mounted. Dimensions: 109 x 23.5 x 104mm. Operating Temperature -20 to +60 C, 0-95%RH (non-condensing).

£200.00
Add to Basket More Info
4510

4510

PR 4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display.

£72.00
Add to Basket More Info
4511

4511

PR 4511 Programming display and Modbus RTU protocol interface for systems 4000 and 9000 devices. Each 4511 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as an RS485 Modbus RTU connection to a local network. The 4511 display clicks onto the front of the device and an RJ45 connector on top of the unit allows for connection to a Modbus network.

£126.00
Add to Basket More Info
4512

4512

PR 4512 Bluetooth Communications Interface. Allows for programming and live readings to a iOS or Android device and any of the 4000 and 9000 Series devices. Each 4512 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as the 4512 can also provide 30 days data logging at 1 second intervals of the connected devices. The 4512 display clicks onto the front of the device and can be connected to a 4590 to allow for a direct connection to a PC to allow for direct configuration, collecting logged data and event logs.

£126.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000