GC-12
Transmitters for use with external probes - Wired socket for 2 x thermistors (-40 to +70C)..
GD-38
GEN II radio transmitter for eight external thermistor probe. Temperature Range -50 to +150°C, Resolution 0.2°C (-40 to +125°C) and Accuracy ±0.4°C (-40 to +125°C). Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display...
GC62EX
GEN II Transmitter for direct connection to a U6-PULSE domestic gas meter. The GC62EX is designed to meet the requirements of IGEM / GM / 7A communications 1731 for connection to a domestic gas meter. The transmitter will accept up to 2 pulse inputs, max 250Hz and 65,000 per logging..
GD-67
GEN II radio transmitter for use with pulse outputs from flow, gas, energy or heat meters and any other devices with a pulse output. The transmitter will accept up to 7 pulse inputs, max 15Hz and 65,000 counts per logging period, counter resets for each transmission. Operating Range -30 to..
GD-68
GEN II radio transmitter for use with pulse outputs from flow, gas, energy or heat meters and any other devices with a pulse output. The transmitter will accept up to 8 pulse inputs, max 15Hz and 65,000 counts per logging period, counter resets for each transmission. Operating Range -30 to..
GD-81
GEN II radio transmitter with integrated barometric pressure sensor. Pressure Range 800-1100mBarA, Resolution 0.0122mBar/bit and Accuracy 1% FSS. Supplied with 4 x AA Alkaline batteries, stub antenna and integrated LCD display...
GD-84
GEN II radio transmitter with integrated differential pressure transducer suitable for clean room applications. Differential Pressure Range -250 to +250Pa, Resolution 0.1Pa and Accuracy 3 Pa. Supplied with 4 x AA Alkaline batteries, stub antenna, integrated LCD display and 2 Cole Parmer quick connectors for 6mm I/D tubing...
GD900A
GEN II radio transmitter for direct connection to up to 6 ND Rail 350 power meter. Suitable for single of three phase energy meters with up to 11 parameters from all 6 meters, default settings are for 3 current phases, 3 power factors, 3 voltage, 1 kWh and 1 kVArH,..
GENII Transmitters
A wide range of transmitter units are available for V, mA, thermocouple, thermistor, and pulse inputs as well as units with integral temperature and humidity sensors. On the voltage and current (4-20mA) input a switched excitation O/P is available to power external sensors:..
GL220-HIRE
GL220 data logger with built-in 4.3" WQVGA TFT LCD Color Display. 10 analog measurement channels, 20mV to 50V, Thermocouples: Type K, J, E, T, R, S, B, N, W. Sampling rate: Max 10ms (1 Channel), 100ms (10 Channels & Thermocouples). 2GB internal flash memory with separate port for USB flash..
GPS16-HVS
GPS 16 HVS GPS receiver, with RS232 O/P, power supply 6-40 vDc, consumption 65mA at 12v Dc, Baud rates: 300 / 600 / 1200 / 2400 / 4800 / 9600 / 19200. Receiver: WAAS-enabled; 12 parallel channel GPS receiver continuously tracks and uses up to 12 satellites to compute and..
GPSCOVERT
GPS covert waterproof antenna with 5m RG174 cable, SMA plug. Covert GPS Antenna with Sticky Pad Adhesive. Ideal for Covert use on vehicles (Fully Waterproof). Dimensions: Width 27mm, Height 10mm...
GRD1000-XF
GRD1000-XF GSM/GPRS modem with an RS232/485 serial port. Can be used to connect any serial device to a remote server running the Middleware software via GPRS. Power supply 9-30vDC. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can..
GRD1300-XF
GRD1300-XF GSM/GPRS data logger and SMS alarm unit with an RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface..
GRD1530-XF
GRD1530-XF GSM/GPRS data logger and SMS alarm unit with two RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface..
GRD3002-XF
GRD3002-XF GSM/GPRS data logger with 6 x 0-10V analogue inputs, 16 digital state inputs and 6 open collector digital outputs. RS232/485 serial port. Power supply 10-30vDC. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web interface can also be used..
GRD3002-XF-PL-MB
GRD3002-XF-PL-MB GSM/GPRS data logger with 6 analogue inputs (0-10v or 4-20mA), 2 pulse inputs, 14 digital state input and 6 open collector digital outputs. RS232/485 serial port MODBUS master (reads up to 32 registers). Power supply 10-30vDC. The GRD will connect to a remote server to generate a MySQL database..
GRD3305-XF
GRD3305-XF GSM/GPRS data logger and SMS alarm unit with 4 analogue inputs (0-1v, 0-10v, 4-20mA), 4 digital state/counter inputs (2 configurable as NPN Outputs). RS232/485 serial port MODBUS master (reads up to 100 registers). Power supply 9-30vDC. USB port for local programming and configuration. The GRD will connect to a..
GRD4003-XF
GRD4003-XF GSM/GPRS data logger with 4 x 4-20mA analogue inputs, 2 x digital pulse inputs, 16 digital state inputs and 6 open collector digital outputs. RS232/485 serial port. Power supply 10-30vDC. The GRD will connect to a remote server to generate a MySQL database for data logging. Our M2M web..
GSMPC
GSM Modem kit (PC Side) suitable for GEN II Systems. The kit consists of the following: Wavecom Xtend modem; Antenna; Modem to PC serial lead (type LC-PC/MDM; AC to 12vDC power supply (type MPGSMextend); and User instructions...
GSMSQ
GSM Modem Kit (Receiver/Logger side) suitable for GEN II Systems. The kit consists of the following: Wavecom Xtend modem; Mounting tabs; Logger to modem lead (type GSM-mdm-com2X); Antenna with 1.8m lead; SMA connector; and User instructions. When installed, access to the Squirrel can be achieved via a GSM network. Note:..
GT Series
GT Series Multi Function Leak Detector. The complete set comes with Carrying Case with Solid End Probe, Tygon Tubing, Hydrophobic Filter (Pack / 4), Wrist Strap, Handbook, Quick Operating Guide, Calibration Certificate and Configuration Report...
GTS-SET
GTS Portable Temp & Humidity instrument for paper and stacks. Display of relative humidity or temperature. Strong, lightweight aluminium sword probe, dimensions 260 x 18 x 5mm. Comes complete with a carry case, calibration device and adjustment tools, includes humidity standards and 5 ampoules 50% RH...
GW-47
GEN II radio transmitter with integrated temperature, relative humidity and CO2 sensors. Temperature Range -30 to +65 C, Resolution 0.1 C and Accuracy 0.4 C (5 to 40 C). Humidity Range 0-100%, Resolution 0.1% and Accuracy 2% (10 to 90%). CO2 Range 0-5,000ppm, Resolution 3% and Accuracy 50ppm. Transmitter requires..