PR5104B Dual Channel Repeater/Power Supply suitable for hazardous area applications. Dual Channel, ATEX II (1) GD, with 2 x 4-20mA inputs, 24-230 vAC/DC power supply, provides 18V loop power to transmitters via zener barrier and 2 x isolated 4-20mA O/P s to external devices...
PR6337D Intrinsically safe 2-Wire programmable transmitter with HART 7 Protocol and an 8-28vDC power supply. Dual channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
B-569 Battery pack for the GL Series data loggers. 7.2V 2900mAh Li-Ion battery pack. A single unit is suitable for powering the GL240, GL840-M & GL840-WV and GL2000 Data Logger. Two packs are required to power the GL-980...
Rechargable battery pack, 24v, 20 amp hour, lithium polymer, operating temperature -20 to +60 deg C, with short circuit, over charge and discharge protection, self discharge rate 0.5% per day. Fitted in IP65 Peli case. With charge indicator. Supplied with smart charger. Weight: 6.0 kg. Dimensions: 300 x 249 x..
MSR145WD External FlexConnect Relative Humidity Sensor. Relative Humidity Range: 0 to 100%RH, Accuracy ±1.8%RH (10...85%, 0...+40°C) & ±4%RH (85...95%, 0...+40°C). Sensor is fitted with cable and FlexConnect connector. The sensor connects to the FlexConnect Box and MSR145WD data logger and will be automatically detected...
GEN II radio transmitter with integrated temperature and relative humidity probe. Temperature Range -30 to +65°C, Resolution 0.1°C and Accuracy ±0.4°C (-5 to +40°C). RH Range 0-100%RH, Resolution 0.1% and Accuracy ±2% (10-90%RH). Supplied with 4 x AA Alkaline batteries and stub antenna...
GL100-WL Petit logger main unit with Wireless LAN connectivity. 4.9MB internal memory and micro SD memory card slot, (max file size 1.9GB). Backlit monochrome display (128Ç?64 dot resolution) displays measured values and settings. 2.4GHz wireless frequency for remote connection to wireless LAN, GL240, GL840 or Smart phone devices. Power Supply..
GS-CO2 Space Mounted Carbon Dioxide Transmitter with Non-Dispersive Infra-Red (NDIR) Sensor, LEDs and LCD Display. Measurement Range: 0-2,000ppm. 3-colour LED indication: Green <1,000ppm; Amber 1,000 to 1,500ppm; Red >1,500ppm. Output: 4-20mA or 0-10vDC selectable. Power supply: 24vDC. IP30 Flame retardant ABS housing, dimensions 115 x 85 x 30mm...
MiniAir 6EX Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-20m/s with a 0-2V output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range -10 to +80°C. Plastic sensing..
Integral in-line signal conditioner module in potted box (25 x 40 x 13mm) fitted to AC LVDT with 0.5m PVC cable tail ends. Power Supply 9-24VDC, Output 0-5V...
Stainless Steel Thermal Barrier for OQ610-S data loggers. Dimensions: 230mm x 300mm x 102mm, weight 9Kg approx. Thermal capacity of 150 min at 100°C or 60 min at 300°C (max internal temp 70°C)...
RH-W-5V-AH Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-5vDC or 4-20mA Outputs. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV Stabilized enclosure with..
SD-15B-12 DC to DC converter. Input Voltage: 18-36vDC. Output Voltage 12vDC @ 15 Watts. Dimensions: 78 x 51 x 28mm. Panel mounted enclosure with short circuit, overload and over-voltage protection...
Stainless steel temperature sensor for TR42 , probe length 185 mm x 3mm diameter, measurement range -60 to +155°C. with 2 metres of cable response time 150 seconds in air, 7 seconds in water. Accuracy Avg. ± 0.3°C at -20 to 80°C Avg. ± 0.5°C at -40 to -20°C, 80..
Spare/replacement cap for the EL-USB-4. The USB-CAP-4-20 provides the connection method to the current loop to be recorded by the EL-USB-4 data logger...
GSKIN Medium Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 10 x 10mm with a 0.5mm thickness. 1m flying lead for direction connection to meter or data logger...
PR5104B Dual Channel Repeater/Power Supply suitable for hazardous area applications. Dual Channel, ATEX II (1) GD, with 2 x 4-20mA inputs, 24-230 vAC/DC power supply, provides 18V loop power to transmitters via zener barrier and 2 x isolated 4-20mA O/P s to external devices. ...
PR6337D Intrinsically safe 2-Wire programmable transmitter with HART 7 Protocol and an 8-28vDC power supply. Dual channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail. ...
B-569 Battery pack for the GL Series data loggers. 7.2V 2900mAh Li-Ion battery pack. A single unit is suitable for powering the GL240, GL840-M & GL840-WV and GL2000 Data Logger. Two packs are required to power the GL-980. ...
Rechargable battery pack, 24v, 20 amp hour, lithium polymer, operating temperature -20 to +60 deg C, with short circuit, over charge and discharge protection, self discharge rate 0.5% per day. Fitted in IP65 Peli case. With charge indicator. Supplied with smart charger. Weight: 6.0 kg. Dimensions: 300 x 249 x 119 mm ...
MSR145WD External FlexConnect Relative Humidity Sensor. Relative Humidity Range: 0 to 100%RH, Accuracy ±1.8%RH (10...85%, 0...+40°C) & ±4%RH (85...95%, 0...+40°C). Sensor is fitted with cable and FlexConnect connector. The sensor connects to the FlexConnect Box and MSR145WD data logger and will be automatically detected. ...
GEN II radio transmitter with integrated temperature and relative humidity probe. Temperature Range -30 to +65°C, Resolution 0.1°C and Accuracy ±0.4°C (-5 to +40°C). RH Range 0-100%RH, Resolution 0.1% and Accuracy ±2% (10-90%RH). Supplied with 4 x AA Alkaline batteries and stub antenna. ...
GL100-WL Petit logger main unit with Wireless LAN connectivity. 4.9MB internal memory and micro SD memory card slot, (max file size 1.9GB). Backlit monochrome display (128Ç?64 dot resolution) displays measured values and settings. 2.4GHz wireless frequency for remote connection to wireless LAN, GL240, GL840 or Smart phone devices. Power Supply 2 x AA Alkaline batteries or USB bus-power. Dimensions 66 x 100 x 27mm. ...
GS-CO2 Space Mounted Carbon Dioxide Transmitter with Non-Dispersive Infra-Red (NDIR) Sensor, LEDs and LCD Display. Measurement Range: 0-2,000ppm. 3-colour LED indication: Green <1,000ppm; Amber 1,000 to 1,500ppm; Red >1,500ppm. Output: 4-20mA or 0-10vDC selectable. Power supply: 24vDC. IP30 Flame retardant ABS housing, dimensions 115 x 85 x 30mm. ...
MiniAir 6EX Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-20m/s with a 0-2V output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range -10 to +80°C. Plastic sensing head with Steel blade turbine suitable for aggressive gas flow measurements. Hazardous Area Certification: Intrinsically Safe EEx ia IIC T6 ...
Integral in-line signal conditioner module in potted box (25 x 40 x 13mm) fitted to AC LVDT with 0.5m PVC cable tail ends. Power Supply 9-24VDC, Output 0-5V. ...
Stainless Steel Thermal Barrier for OQ610-S data loggers. Dimensions: 230mm x 300mm x 102mm, weight 9Kg approx. Thermal capacity of 150 min at 100°C or 60 min at 300°C (max internal temp 70°C). ...
RH-W-5V-AH Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-5vDC or 4-20mA Outputs. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV Stabilized enclosure with an IP54 rating. Dimensions 102 x 105 x 85mm ...
SD-15B-12 DC to DC converter. Input Voltage: 18-36vDC. Output Voltage 12vDC @ 15 Watts. Dimensions: 78 x 51 x 28mm. Panel mounted enclosure with short circuit, overload and over-voltage protection. ...
Stainless steel temperature sensor for TR42 , probe length 185 mm x 3mm diameter, measurement range -60 to +155°C. with 2 metres of cable response time 150 seconds in air, 7 seconds in water. Accuracy Avg. ± 0.3°C at -20 to 80°C Avg. ± 0.5°C at -40 to -20°C, 80 to 110°C. Avg. ± 1.0°C at -60 to -40°C, 110 to 155°C ...
Spare/replacement cap for the EL-USB-4. The USB-CAP-4-20 provides the connection method to the current loop to be recorded by the EL-USB-4 data logger. ...
GSKIN Medium Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 10 x 10mm with a 0.5mm thickness. 1m flying lead for direction connection to meter or data logger. ...
PR5104B Dual Channel Repeater/Power Supply suitable for hazardous area applications. Dual Channel, ATEX II (1) GD, with 2 x 4-20mA inputs, 24-230 vAC/DC power supply, provides 18V loop power to transmitters via zener barrier and 2 x isolated 4-20mA O/P s to external devices...
PR6337D Intrinsically safe 2-Wire programmable transmitter with HART 7 Protocol and an 8-28vDC power supply. Dual channel unit for RTD, TC, Ohm or mV input, producing a 4-20mA output. 1.5kvAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail...
B-569 Battery pack for the GL Series data loggers. 7.2V 2900mAh Li-Ion battery pack. A single unit is suitable for powering the GL240, GL840-M & GL840-WV and GL2000 Data Logger. Two packs are required to power the GL-980...
Rechargable battery pack, 24v, 20 amp hour, lithium polymer, operating temperature -20 to +60 deg C, with short circuit, over charge and discharge protection, self discharge rate 0.5% per day. Fitted in IP65 Peli case. With charge indicator. Supplied with smart charger. Weight: 6.0 kg. Dimensions: 300 x 249 x..
MSR145WD External FlexConnect Relative Humidity Sensor. Relative Humidity Range: 0 to 100%RH, Accuracy ±1.8%RH (10...85%, 0...+40°C) & ±4%RH (85...95%, 0...+40°C). Sensor is fitted with cable and FlexConnect connector. The sensor connects to the FlexConnect Box and MSR145WD data logger and will be automatically detected...
GEN II radio transmitter with integrated temperature and relative humidity probe. Temperature Range -30 to +65°C, Resolution 0.1°C and Accuracy ±0.4°C (-5 to +40°C). RH Range 0-100%RH, Resolution 0.1% and Accuracy ±2% (10-90%RH). Supplied with 4 x AA Alkaline batteries and stub antenna...
GL100-WL Petit logger main unit with Wireless LAN connectivity. 4.9MB internal memory and micro SD memory card slot, (max file size 1.9GB). Backlit monochrome display (128Ç?64 dot resolution) displays measured values and settings. 2.4GHz wireless frequency for remote connection to wireless LAN, GL240, GL840 or Smart phone devices. Power Supply..
GS-CO2 Space Mounted Carbon Dioxide Transmitter with Non-Dispersive Infra-Red (NDIR) Sensor, LEDs and LCD Display. Measurement Range: 0-2,000ppm. 3-colour LED indication: Green <1,000ppm; Amber 1,000 to 1,500ppm; Red >1,500ppm. Output: 4-20mA or 0-10vDC selectable. Power supply: 24vDC. IP30 Flame retardant ABS housing, dimensions 115 x 85 x 30mm...
MiniAir 6EX Macro vane anemometer. Sensing head 85mm diameter x 80mm, probe length 225mm. Air velocity range 0-20m/s with a 0-2V output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range -10 to +80°C. Plastic sensing..
Integral in-line signal conditioner module in potted box (25 x 40 x 13mm) fitted to AC LVDT with 0.5m PVC cable tail ends. Power Supply 9-24VDC, Output 0-5V...
Stainless Steel Thermal Barrier for OQ610-S data loggers. Dimensions: 230mm x 300mm x 102mm, weight 9Kg approx. Thermal capacity of 150 min at 100°C or 60 min at 300°C (max internal temp 70°C)...
RH-W-5V-AH Wall-mounted Air Temperature and Relative Humidity transmitter with Jumper Selectable 0-5vDC or 4-20mA Outputs. Measurement Range 0-100% RH, -20 to +50°C with an accuracy of ±2%RH (20 to 80%RH), ±0.5°C. Power Supply: 24vDC ±10%. Unit is housed in a PC/GF (Halogen free, Flame Retardant & UV Stabilized enclosure with..
SD-15B-12 DC to DC converter. Input Voltage: 18-36vDC. Output Voltage 12vDC @ 15 Watts. Dimensions: 78 x 51 x 28mm. Panel mounted enclosure with short circuit, overload and over-voltage protection...
Stainless steel temperature sensor for TR42 , probe length 185 mm x 3mm diameter, measurement range -60 to +155°C. with 2 metres of cable response time 150 seconds in air, 7 seconds in water. Accuracy Avg. ± 0.3°C at -20 to 80°C Avg. ± 0.5°C at -40 to -20°C, 80..
Spare/replacement cap for the EL-USB-4. The USB-CAP-4-20 provides the connection method to the current loop to be recorded by the EL-USB-4 data logger...
GSKIN Medium Heat Flux Sensor. Heat flux range -150 to +150kW/m², min sensitivity 7.0µV/(W/m²), response time 0.7 secs. Plate sensing area is 10 x 10mm with a 0.5mm thickness. 1m flying lead for direction connection to meter or data logger...
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.