Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

Uncategorised

Home / Uncategorised / Page 11

9202A2B

Pulse isolator, 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.O. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function...
View Product

9202B2B

Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.O. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply...
View Product

9203A1A2

Solenoid and alarm driver, 1 channel driver output, NPN input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
View Product

9203B1A2

Solenoid and alarm driver, ATEX approved 1 channel driver output, NPN input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
View Product

HPA-110

4dBi omni-directional dipole antenna, up to 500m service range, 7" high with SMA connector..
View Product

HPP-120-US

120VAC Power Supply, standard US AC plug pack adapter..
View Product

HPS-120-SMAMFDRA

HPS 120 Antenna, 1/4 wave, with right angled SMA male connection. 2.4 GHz..
View Product

MIEX06124

MiniAir 6EX Mini vane anemometer. Sensing head 22mm diameter x 28mm, probe length 175mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range -10 to +80°C. Plastic sensing..
View Product

SGR522

SGR522 TorqSense Torque sensor with variable analogue outputs for Torque, Speed and Power measurements with integral electronics. Torque ranges from 0-175mNm to 0-13,000 Nm and 360 Pulse/Revolution...
View Product

TMS3000-BD

TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with digital O/P interface ( bus system )..
View Product

TMS3000-BAD

TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with analog O/P and Profibus O/P..
View Product

0373900-001

PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 5m length...
View Product

0373900-003

PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 15m length...
View Product

10130053B

ComNav G2 GNSS Satellite with G2 Compass Differential GPS (DGPS) correction, G2 Navigator Colour Display and 30m cable. Output: NMEA0183. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC..
View Product

111-90

P11 Rod Glass Combination pH Electrode for a pH range of 0-14. Combination electrode with a Silver Chloride, liquid filled, single annular ceramic junction. Eo point -25 to +25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 100 C. Suitable for..
View Product

9202B3A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply...
View Product

9203A1B

Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...
View Product

DLOG-4231

gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN..
View Product
GSKIN U-Value and Heat Flux Measurement Kit

GSKINKIT-2615C

gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger,..
View Product

HPP-110

9V PP3 Power Supply cable for HPS-120 radio modems. Allows the HPS120 transceiver to be powered by a standard 9V PP3 battery. Battery not included...
View Product
MC-7828G Grain Moisture Meter Sampling Cup Measurement

OMNI-MC-7828G

MC-7828G Grain Moisture Meter with cup measurements. LCD Display, range 0-50% in an operating range of 0-50°C...
View Product
RI-TVV0010 Voltage Transducer

RI-TVV0020L

RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm...
View Product
SharpEye 40/40C-M Multi-Spectrum Quad-Sense Flame Detector.

SharpEye 40/40C-M Flame Detector

SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...
View Product
SharpEye 40/40D-M Multi IR Quad-Sense Flame Detector.

SharpEye 40/40D-M Flame Detector

SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt..
View Product

9202A2B

Pulse isolator, 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.O. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply. With cable fault check (LFD) function...
View Product

9202B2B

Pulse isolator, I.S ATEX approved 2 channel with NAMUR/contact input frequency range 0-5 KHz, and N.O. SPST relay outputs, SIL 2, isolated, 19.2 - 31.2 VDC supply...
View Product

9203A1A2

Solenoid and alarm driver, 1 channel driver output, NPN input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
View Product

9203B1A2

Solenoid and alarm driver, ATEX approved 1 channel driver output, NPN input, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. Relay output...
View Product

HPA-110

4dBi omni-directional dipole antenna, up to 500m service range, 7" high with SMA connector..
View Product

HPP-120-US

120VAC Power Supply, standard US AC plug pack adapter..
View Product

HPS-120-SMAMFDRA

HPS 120 Antenna, 1/4 wave, with right angled SMA male connection. 2.4 GHz..
View Product

MIEX06124

MiniAir 6EX Mini vane anemometer. Sensing head 22mm diameter x 28mm, probe length 175mm. Air velocity range 0-40m/s with a 0-2V output. Accuracy ±1% of full scale, ±3% of reading. Power supply 9-24vDC Sensor is supplied with 20m cable to zener barrier housing. Operating range -10 to +80°C. Plastic sensing..
View Product

SGR522

SGR522 TorqSense Torque sensor with variable analogue outputs for Torque, Speed and Power measurements with integral electronics. Torque ranges from 0-175mNm to 0-13,000 Nm and 360 Pulse/Revolution...
View Product

TMS3000-BD

TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with digital O/P interface ( bus system )..
View Product

TMS3000-BAD

TMS3000 tunnel measuring system comprising of 2 DP sensors connected to control unit with analog O/P and Profibus O/P..
View Product

0373900-001

PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 5m length...
View Product

0373900-003

PQS 1 Quantum Sensor for Photosynthetically Active Radiation. Spectral range 400-700nm, response time 1ss, non-linearity 1%, directional error 3% (at 80 solar zenith angle), sensitivity 4 - 10V/mol/sm, operating temperature -30C to +70C. Photo-diode detector, diffuser and optical interference filter, mV output and standard captive cable of 15m length...
View Product

10130053B

ComNav G2 GNSS Satellite with G2 Compass Differential GPS (DGPS) correction, G2 Navigator Colour Display and 30m cable. Output: NMEA0183. Update rate: Heading & position updates at up to 20 times per second, and can operate at sustained turn rates up to 90° per second. Power Supply 10 to 36vDC..
View Product

111-90

P11 Rod Glass Combination pH Electrode for a pH range of 0-14. Combination electrode with a Silver Chloride, liquid filled, single annular ceramic junction. Eo point -25 to +25mV. Shaft dimensions (approx) 12mm diameter and 120mm length. BNC connector with 1m cable. Operating temperature 0 to 100 C. Suitable for..
View Product

9202B3A

Pulse isolator, I.S ATEX approved 1 channel with NAMUR/contact input frequency range 0-5 KHz, and N.C. SPST relay output, SIL 2, isolated, 19.2 - 31.2 VDC supply...
View Product

9203A1B

Solenoid and alarm driver, 2 channel driver output, 2 digital switch inputs, SIL 2, low current version (35 mA), 19.2 - 31.2 VDC supply. 2 relay outputs...
View Product

DLOG-4231

gSKIN Heat Flux Data Logger with autonomous, live and trigger logging modes. Internal memory for up to 2 million data points, logging rate 50Hz to 12 hours and internal rechargeable Lithium battery for up to 30 days logging, dependent on logging rate. 0.5m cable to TEG connector for connecting gSKIN..
View Product
GSKIN U-Value and Heat Flux Measurement Kit

GSKINKIT-2615C

gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger,..
View Product

HPP-110

9V PP3 Power Supply cable for HPS-120 radio modems. Allows the HPS120 transceiver to be powered by a standard 9V PP3 battery. Battery not included...
View Product
MC-7828G Grain Moisture Meter Sampling Cup Measurement

OMNI-MC-7828G

MC-7828G Grain Moisture Meter with cup measurements. LCD Display, range 0-50% in an operating range of 0-50°C...
View Product
RI-TVV0010 Voltage Transducer

RI-TVV0020L

RI-TV Series Loop Powered Isolated True RMS Voltage Transducer. DIN Rail Mounted with Screw Terminals. Selectable Input Range: 0-24, 0-36, 0-54, 0-80, 0-120, 0-170, 0-250, 0-400, 0-450, 0-500vAC. Selectable Output Range: 4-20mA. Loop Power Supply: 9-30vDC. Operating Temp -20 to +60°C, IP20. Dimensions 90 x 57.5 x 36mm...
View Product
SharpEye 40/40C-M Multi-Spectrum Quad-Sense Flame Detector.

SharpEye 40/40C-M Flame Detector

SharpEye 40/40C-M Multispectrum Quad-Sense Flame Detector. 5 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical, (Hydrogen 90°). Response time: Typically< 5 Seconds. 0-5V analogue output, SPST Volt Free Alarm, Fault and Auxiliary relays. Stepped 0-20mA signal with HART Comms, plus RS485 Modbus Comms. Power Supply: 18-32vDC...
View Product
SharpEye 40/40D-M Multi IR Quad-Sense Flame Detector.

SharpEye 40/40D-M Flame Detector

SharpEye 40/40D-M Ultra Fast Multi IR Quad-Sense Flame Detector. Spectral Response: Four Infrared (IR) bands between 2µm and 5µm, 6 sensitivity ranges and Field of View of 80° Horizontal & 80° Vertical. Standard (<2 secs), Ultra Fast (<1 Sec) and High speed response of 50mSecs. 0-5V analogue output, SPST Volt..
View Product

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000