Description
IMU Connector Manufacturer: | Harwin |
IMU Connector Housing: | G125-2041096L0 |
Contacts: | G125-0020005 |
Encapsulant: | Stycast 2651, Catalyst 9 |
Host Connector Manufacturer: | Hirose |
Host Connector Part No.: | HR30-6P-6S |
Overall Length: | 36 Inches |
Cable Manufacturer: | Microflex Wire & Cable |
Cable Part No.: | BN103025FEPUSIL |
Cable Jacket: | Silicon Rubber |
Cable OD: | 0.115 inches |
Wire Gauge: | AWG 30 |
Wire Insulation: | FEP |
IMU Pin | Host Pin |
||
No. | Wire Colour | No. | Signal Name |
1 | Red | 2 | PWR |
2 | None | Not Connected | |
3 | Orange | Fig 3 | 1 PPS |
4 | Green | 1 | RCV A |
5 | White | 6 | RCV B |
6 | Black | 5 | GND |
7 | Violet | Fig 3 | TOV |
8 | Brown | Fig 3 | X TRIG |
9 | Yellow | 3 | TX Y |
10 | Blue | 4 | TX Z |