The PR5131A converts temperature and analogue process signals into an isolated 4–20 mA output for connection to PLCs, data loggers and control systems. Available in single and dual channel versions, it combines configurable inputs with two-wire, loop-powered operation in a DIN rail mounted housing. It provides a flexible interface for installations using different sensor types and measurement ranges.
The 5131A accepts RTD, thermocouple, linear resistance, mV, current and DC voltage inputs. It can be configured for temperature measurement, resistance-based position feedback or conversion of existing instrument outputs. Programmable ranges accommodate current inputs within 0–100 mA and voltage inputs within 0–250 vDC.
For RTD measurements, three- and four-wire connections provide automatic cable resistance compensation. Two-wire installations can use a configured cable resistance value to compensate for lead resistance.
The single channel version handles one measurement signal, while the dual channel version provides two independently configured channels. Each channel can perform a different task, allowing temperature measurement and process signal conversion within the same unit. Full galvanic isolation between channels keeps the two measurement circuits electrically separate.
Each channel operates from its 4–20 mA output loop, simplifying power wiring. The specified transmitter supply range is 7.5–35 VDC, with the available output load determined by the loop supply voltage.
Galvanic isolation separates input and output circuits, with a 3.75 kVAC isolation test rating. Configurable sensor error signalling allows receiving equipment to distinguish a detected sensor fault from a normal measurement.
Configuration uses PReset software and a Loop Link communications interface. Settings include input type, measurement range, response time and sensor fault behaviour. Internal jumpers select the temperature or current/voltage input category for each channel. The configuration is retained when power is removed.
| Type | Version | Input | Channels |
| 5131 | A: General Purpose, Zone 2, Div 2 | – : RTD/TC/R/mA/V/mV | A: Single B: Dual |
Applications
Frequently Asked Questions
Single Channel PR 5131A-A 2-Wire Programmable Universal Transmitter with DC power supply. Input: RTD; Thermocouples; Ohm; potentiometers; mA; V. Output: 4-20mA. Galvanic isolation of input and output. Power supply 7.5–35vDC. DIN Rail mounted. Dimensions: 109 x 23.5 x 130mm. Operating Temperature -20 to +60°C, 0-95%RH (non-condensing).
Dual Channel PR 5131AB 2-Wire Programmable Universal Transmitter with DC power supply. Input: RTD; Thermocouples; Ohm; potentiometers; mA; V. Output: 4-20mA. Galvanic isolation of inputs and outputs. Power supply 7.5–35vDC. DIN Rail mounted. Dimensions: 109 x 23.5 x 130mm. Operating Temperature -20 to +60°C, 0-95%RH (non-condensing).
CJC Connector for Single channel units. CJC connector for channel 1: 4114, 4116, 4131, 5114A, 5115A, 5116A, 5131A, 6331A, 6335A, 6337A, 9113A, and 9116A.
CJC Connector for Dual channel units. CJC connector for channel 2: 5114A, 5115A, 5131A, 6331A, 6335A, 6337A, and 9113A
USB Loop Link programming kit to configure PR Electronics 5000 & 6000 Series devices. Loop Link 5909 consists of a communication box with USB cable to the PC, necessary cables for connection to the devices, a CD-ROM with the configuration program PReset and an installation manual. The communication box is powered by the USB port of the PC.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.