The PR4104 is a universal unipolar and bipolar signal transmitter for converting, scaling and isolating DC current and voltage signals. Its configurable inputs and outputs provide an interface between instruments and control equipment operating with different signal ranges. A universal AC/DC supply and configuration through compatible PR 4500-series interfaces make it suitable for industrial control-panel installations.
The 4104 handles signals operating in one polarity, such as 0–10 V or 4–20 mA, and bipolar signals spanning positive and negative values, such as ±10 V. It can convert between supported current and voltage ranges to match the requirements of the receiving equipment.
For example, a ±1 V input can be scaled to a ±10 V or 4–20 mA output. This allows a compatible sensor or instrument to connect to a PLC, indicator or data acquisition system without requiring matching input and output ranges.
The analogue output can be configured for direct or inverted action. Direct action increases the output as the input rises, while inverted action reverses that relationship.
A V-curve function provides an additional conversion characteristic, producing a 100–0–100% output across a linear 0–100% input range. Programmable damping allows the output response to be adjusted where a steadier indication is required.
The 4104 supports active current outputs and passive two-wire current output arrangements. The correct configuration depends on whether the connected equipment supplies loop power or expects the transmitter to drive the current signal.
Voltage output options provide an alternative for compatible receiving inputs. The selected range, wiring and load must suit the complete signal circuit.
Auxiliary supplies allow the 4104 to power compatible two- or three-wire transmitters. This combines transmitter interfacing and signal conversion within one device.
Galvanic isolation separates the connected circuits, with a specified isolation test voltage of 2.3 kVAC. This supports applications requiring electrical separation, including suitable floating-signal measurements.
A compatible detachable PR 4500-series interface provides access to programming and process monitoring. Settings are selected to match the input signal, output range and required conversion behaviour.
The transmitter provides a response time below 20 ms under the specified conditions. Adjustable output damping can extend this response to suit the application.
The 4104 mounts on a standard 35 mm DIN rail and accepts 21.6–253 VAC or 19.2–300 VDC. Its universal supply allows use in panels with different power arrangements.
Before selection, confirm the signal polarity, input and output ranges, active or passive loop arrangement and connected load. For direct RTD or thermocouple measurement, choose a suitable temperature or universal transmitter such as the PR 4114.
Applications
Frequently Asked Questions
PR 4104 Universal Uni-/Bi-Polar Signal Transmitter with universal AC or DC power supply. Programmable Inputs: Current - 0-20mA, 4-20mA, ±10mA or ±20mA; Voltage - 0-1V, 0.2-1V, 0-5V, 1.5V, 0-10V, 2-10V, ±1V, ±5V or ±10V. Outputs: Active Current - 0-20mA, 4-20mA, ±10mA or ±20mA; Passive Current - 0-20mA, 4-20mA; Voltage - 0-1V, 0.2-1V, 0-5V, 1.5V, 0-10V, 2-10V, ±1V, ±5V or ±10V. Power supply 21.6 - 253vAC or 19.2 - 300vDC. DIN Rail mounted. Dimensions: 109 x 23.5 x 104mm. Operating Temperature -20 to +60°C, 0-95%RH (non-condensing).
PR 4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display.
PR 4511 Programming display and Modbus RTU protocol interface for systems 4000 and 9000 devices. Each 4511 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as an RS485 Modbus RTU connection to a local network. The 4511 display clicks onto the front of the device and an RJ45 connector on top of the unit allows for connection to a Modbus network.
PR 4512 Bluetooth Communications Interface. Allows for programming and live readings to a iOS or Android device and any of the 4000 and 9000 Series devices. Each 4512 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as the 4512 can also provide 30 days data logging at 1 second intervals of the connected devices. The 4512 display clicks onto the front of the device and can be connected to a 4590 to allow for a direct connection to a PC to allow for direct configuration, collecting logged data and event logs.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.