The PR4225 is a universal frequency converter for connecting pulse and frequency signals to industrial monitoring and control systems. It accepts supported NAMUR, NPN, PNP, tacho, TTL, S0 and contact inputs, with analogue, frequency or relay outputs depending on the selected version. Configurable signal processing allows measurements from compatible flowmeters, speed sensors and other pulse-output devices to be matched to receiving equipment.
The 4225 converts a measured frequency into a current or voltage output representing the process value. This allows a compatible pulse-output sensor to connect to equipment with an analogue input, such as a PLC, indicator or data acquisition system.
Available analogue functions include active or passive current outputs and bipolar current or voltage ranges. Input and output scaling establish the relationship between the sensor frequency and the reported measurement.
Suitable versions provide NPN or PNP frequency outputs, allowing the input measurement to be converted into a frequency range and electrical format accepted by downstream equipment.
Relay-equipped versions support setpoint, window and latch functions. These provide switching actions based on configured conditions, such as a measured value reaching a limit or moving outside a permitted range. The output arrangement should be selected to match the monitoring task.
Programmable trigger levels help match the converter to supported sensor signals. A configurable 5–17 V sensor supply can power compatible devices within its current limit.
The input can measure frequencies up to 100 kHz, subject to configuration and signal requirements. An input filter is available for appropriate low-frequency signals, with reduced frequency capability when enabled. NAMUR sensor error detection provides additional monitoring for compatible installations.
A compatible detachable PR 4500-series interface provides configuration, monitoring and diagnostic access. Settings can be password protected to control access.
Two-point process calibration helps align the measurement with the application, while process-value simulation supports commissioning and checks of receiving equipment. Linear and square-root processing options accommodate different measurement relationships.
The 4225 provides three-port galvanic isolation with a specified test voltage of 2.3 kVAC. Its universal supply accepts 21.6–253 VAC or 19.2–300 VDC, allowing integration into different control-panel power arrangements.
The DIN rail housing supports compact panel installation. Before ordering, confirm the sensor type, frequency range, required outputs and supply. Where the task requires conversion from an analogue or temperature input into frequency, consider the PR 4222.
| Type | Version |
| 4222 | A: 1 Analogue Output and 1 Relay
B: 2 Relays C: 1 Analogue Output and 1 Frequency Output |
Applications
Frequently Asked Questions
4225A Programmable Universal f/f & f/I Converter. Outputs: 1 Analogue (Current: 0-20, 4-20, ±10mA, or ±20mA; Voltage: 0-5, 1-5, 0-10, 2-10, ±5, ±10vDC) and 1 Relay Output (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 21.6-253vAC or 19.2-300vDC
4225B Programmable Universal f/f Converter. 2 Relay Outputs (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 21.6-253vAC or 19.2-300vDC
4225C Programmable Universal f/f & f/I Converter. Outputs: 1 Analogue (Current: 0-20, 4-20, ±10mA, or ±20mA; Voltage: 0-5, 1-5, 0-10, 2-10, ±5, ±10vDC) and 1 Frequency Output (Frequency (0.001-100kHz: NPN/PNP/Push-Pull output: 5-24vDC@ 130mA). Power Supply: 21.6-253vAC or 19.2-300vDC
PR 4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display.
PR 4511 Programming display and Modbus RTU protocol interface for systems 4000 and 9000 devices. Each 4511 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as an RS485 Modbus RTU connection to a local network. The 4511 display clicks onto the front of the device and an RJ45 connector on top of the unit allows for connection to a Modbus network.
PR 4512 Bluetooth Communications Interface. Allows for programming and live readings to a iOS or Android device and any of the 4000 and 9000 Series devices. Each 4512 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as the 4512 can also provide 30 days data logging at 1 second intervals of the connected devices. The 4512 display clicks onto the front of the device and can be connected to a 4590 to allow for a direct connection to a PC to allow for direct configuration, collecting logged data and event logs.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.