PR Electronics head-mounted HART transmitters combine sensor signal conversion with digital communication in a compact, loop-powered device. The 5335A, 5335D, 5337A and 5337D accept RTD, thermocouple, resistance and millivolt inputs, converting the selected measurement into a 4–20 mA output with HART communication. Designed for DIN form B sensor heads, they allow conversion close to the sensor while providing configuration and measurement access through compatible HART equipment.
These transmitters support individual temperature measurement and, with suitable sensor arrangements, the difference or average of two temperatures. This allows a single transmitter to report a measurement point, compare two locations or provide an averaged value.
Their input flexibility also extends beyond temperature. Resistance and bipolar millivolt signals can be converted into a standard current output, allowing suitable resistive sensors and low-level voltage sources to connect to industrial monitoring and control systems.
The two-wire connection carries both transmitter power and the measurement signal. HART communication adds digital access over the same loop, allowing compatible equipment to read device information and configure parameters such as sensor type, measurement range and fault response.
In a conventional point-to-point installation, the 4–20 mA output represents the configured process value while HART provides additional digital information. This supports commissioning and maintenance without requiring a separate communication cable to the transmitter.
The 5335A and 5335D use HART 5 communication and provide configurable conversion for temperature, resistance and millivolt measurements. RTD and resistance inputs support two-, three- and four-wire connections, with cable compensation appropriate to the selected arrangement. Programmable sensor error indication helps the receiving system identify a measurement fault.
The 5335A suits general industrial installations and permitted Zone 2/22 applications under its approval conditions. The 5335D provides the intrinsically safe option for hazardous-area installations, subject to its certification and the requirements of the complete circuit.
The 5337A and 5337D allow the HART revision to be configured as HART 5 or HART 7. This provides a choice between compatibility with existing HART 5 systems and the additional communication features available with HART 7.
HART 7 functions include longer device tags, enhanced burst communication, time-stamped event notifications and flexible mapping of device variables. These features support installations where access to measurement status and diagnostic information is useful alongside the main analogue output.
The 5337A is intended for safe-area or permitted Zone 2/22 installations. The 5337D provides the intrinsically safe alternative for hazardous gas and dust environments, within its certified installation conditions.
Choose between the 5335 and 5337 families according to the HART functionality required by your control or asset-management system. The 5335 models provide HART 5 communication, while the 5337 models offer selectable HART 5 or HART 7 operation.
Then select the A or D version to match the installation requirements. For hazardous-area use, check the transmitter approval, enclosure, sensor connections and associated equipment together. Finally, confirm the sensor type, wiring arrangement, measurement range and loop supply to ensure the selected transmitter fits the application.
The PR5335A is a head-mounted 2-wire transmitter that converts RTD, thermocouple, resistance and millivolt inputs into a 4-20 mA output with HART 5 communication. Designed for DIN form B sensor heads, it supports individual, differential or average temperature measurement with compatible sensors. Programmable sensor error indication and HART configuration provide flexibility for industrial monitoring and control applications.
The PR5335D is an intrinsically safe, head-mounted 2-wire transmitter that converts RTD, thermocouple, resistance and millivolt inputs into a 4–20 mA output with HART 5 communication. Designed for DIN form B sensor heads, it supports individual, differential or average temperature measurement with compatible sensors. Galvanic isolation and hazardous-area approvals suit industrial installations requiring intrinsically safe measurement, subject to certification conditions.
The PR5337A is a head-mounted 2-wire transmitter that converts RTD, thermocouple, resistance and bipolar millivolt inputs into a 4-20 mA output with selectable HART 5 or HART 7 communication. Designed for DIN form B sensor heads, it supports individual, differential or average temperature measurement with compatible sensors, alongside digital configuration and status information. It suits general industrial and permitted Zone 2/22 installations.
The PR5337D is an intrinsically safe, head-mounted 2-wire transmitter that converts RTD, thermocouple, resistance and bipolar millivolt inputs into a 4-20 mA output with selectable HART 5 or HART 7 communication. Designed for DIN form B sensor heads, it supports individual, differential or average temperature measurement with compatible sensors. Hazardous-area approvals and digital configuration and diagnostics suit demanding industrial measurement applications.
A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.
Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.