Skip to content

omni instruments | sensors and data acquisition equipment

Omni Instruments Ltd

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
Omni Instruments Ltd
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Products
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • Our Brands
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket

PR Electronics

Home / Our Brands / PR Electronics / Multi-Function Devices / Trip Amplifiers & Transmitters with Alarms / PR4131 Universal Trip Amplifier

PR4131 Universal Trip Amplifier

Universal Signal Monitoring and Alarm Switching

The PR4131 universal trip amplifier monitors a temperature or process signal and provides two relay outputs for alarm switching and control. Its configurable input accepts RTD sensors, thermocouples, resistance, potentiometers, current and voltage signals, allowing the same module to support different measurement tasks across an installation.

Connect temperature sensors directly or monitor signals such as 4–20 mA from a pressure, level or other process transmitter. The PR4131 compares the measured value with configured limits and switches its potential-free relay contacts according to the selected alarm functions.

Adjustable Limits and Relay Functions

Two adjustable alarm limits allow separate switching points for the measured signal. Window operation provides monitoring against upper and lower limits, while a latching function keeps an alarm active until it is manually reset.

Adjustable hysteresis establishes a difference between the switching and reset points, helping prevent repeated relay operation when a signal fluctuates around a threshold. Separate on and off delays allow the switching response to account for brief process changes.

Sensor error monitoring can also be assigned to a relay, providing a separate indication of a detected sensor fault.

Isolated DIN Rail Installation

Three-port galvanic isolation separates the input, relay outputs and power supply. The universal supply accepts 21.6–253vAC or 19.2–300vDC, supporting installation in a range of control panels.

The PR4131 suits installations requiring two relay outputs from one measured signal. Its configurable input and alarm functions allow it to be adapted when sensors, measurement ranges or switching requirements change.

Programming and Monitoring the PR4131

With the PR4131, the selected interface provides access to input configuration and the two relay outputs, including alarm limits, hysteresis, switching delays and sensor error functions. The local display allows operators to view the measured value and check operating status, while relay simulation supports testing during commissioning. Choose the 4510 for local setup, the 4511 for Modbus RTU monitoring, or the 4512 for Bluetooth access and logging to help investigate process changes and alarm activity.

Applications

Configuring the two independent relays to control high/low temperature limits via Pt100 RTD or Thermocouple sensors, triggering safety blowers or isolation valves if the value leaves a predefined safe operational window.
Mapping a 0-100kΩ potentiometer or 4-20mA level probe input to a latched high-level relay state, guaranteeing that emergency pump-shutoffs remain engaged until manual maintenance intervention resets the module.
Utilising the advanced sensor error surveillance mode where Relay 1 "holds" the last valid measurement during unexpected sensor failure (preventing total production line shutdown) while Relay 2 flashes an independent automated control room diagnostic alert.

Frequently Asked Questions

â–¶ Q: What does the PR 4131 do?
A: The PR 4131 universal trip amplifier monitors a sensor or process signal and switches two relay outputs according to configured alarm conditions.
â–¶ Q: Which input signals can it accept?
A: It accepts RTDs such as Pt100, thermocouples, resistance, potentiometers, and standard current or voltage signals, including 4–20 mA and 0–10 V.
â–¶ Q: Can I set separate high and low alarms?
A: Yes. The two relays can have separate alarm settings. Window mode also allows switching based on upper and lower limits.
â–¶ Q: How can I prevent repeated switching near an alarm threshold?
A: Adjustable hysteresis and on/off delays help prevent relay chatter when the measured signal fluctuates around a setpoint.
â–¶ Q: Can an alarm remain active until manually reset?
A: Yes. The latch function keeps an alarm active until it is manually reset.
â–¶ Q: Can it detect a sensor fault?
A: Yes. Sensor error monitoring supports configurable relay responses, including using one relay as a dedicated fault alarm.
▶ Q: Does the PR 4131 provide a 4–20 mA output?
A: No. It provides two relay outputs. If you need an analogue output alongside two relays, consider the PR 4116.

4131

4131

PR4131 universal trip amplifier, input range -20mV-12vDC, 0.2 - 1v, 4-20mA, 0-20mA,-1 to 25mA, PT100, thermocouples types Type B, E, J, K, L, N, R, S, T, U, W3, W5, LR, resistance, with 2 relay outputs. Power supply 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC. Unit provides auxiliary supplies: 2-wire supply (terminal 44...43) ......... 25...16 VDC / 0...20 mA to external sensors.

£175.00
Add to Basket More Info
4510

4510

PR 4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display.

£72.00
Add to Basket More Info
4511

4511

PR 4511 Programming display and Modbus RTU protocol interface for systems 4000 and 9000 devices. Each 4511 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as an RS485 Modbus RTU connection to a local network. The 4511 display clicks onto the front of the device and an RJ45 connector on top of the unit allows for connection to a Modbus network.

£126.00
Add to Basket More Info
4512

4512

PR 4512 Bluetooth Communications Interface. Allows for programming and live readings to a iOS or Android device and any of the 4000 and 9000 Series devices. Each 4512 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as the 4512 can also provide 30 days data logging at 1 second intervals of the connected devices. The 4512 display clicks onto the front of the device and can be connected to a 4590 to allow for a direct connection to a PC to allow for direct configuration, collecting logged data and event logs.

£126.00
Add to Basket More Info

CONTACT US

8:30am to 5pm Monday to Thursday
8:30am to 3pm on Friday.

  • +44 (0) 1382 443000
  • info@omni.uk.com

A real person will answer the phone and deal with your enquiry.
You can also click the button below and fill in our online enquiry form.

Technical Sales

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

        We are here to help

        Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

        Call us on +44 (0)1382 443000