omni instruments | sensors and data acquisition equipment

Sales & Technical Support

9116 Universal Converter

Universal converter module, detachable front programming unit 4510, can be configured for all types of standard industrial measuring signals such as RTD, TC, Ohm, potentiometer, mA and V.

Need help finding the right product?

Description

Applications

  • Configuration and monitoring by way of detachable display front (PR 4501); process calibration, signal and relay simulation.
  • Advanced relay configuration, e.g. setpoint, window, delay, sensor error indication and power monitoring.
  • Copying of the configuration from one device to others of the same type via PR4501.
  • Reduced Uo Ex data < 8.3 V for active input signals.
  • TC inputs with internal or external CJC for higher accuracy.
  • The device automatically detects whether it must supply an active or a passive current signal.

Features

  • Input for RTD, TC, Ohm, potentiometer, mA and V
  • Supply for 2-wire transmitters
  • Active/passive mA output and relay output
  • Can be supplied separately or installed on a power rail, PR 9400
  • SIL 2-certified via Full Assessment
  • Programmable via detachable display front (4501), process calibration, signal and relay simulation, password protection, error diagnostics and selection of help text in several languages.

4510 Display/Programming Interface

Application:

  • Communications interface for modification of operational parameters in 9116.
  • Can be moved from one 9116 module to another and download the configuration of the first converter to subsequent converters.
  • Fixed display for readout of process data and status

Technical characteristics:

  • LCD display with 4 lines; line 1 (H = 5.57 mm) shows input signal, line 2 (H = 3.33 mm) shows units. Line 3 alternates between digital output value and scaling (kHz, Hz, mHz, P/m, P/h, P/d) or shows TAG no. Line 4 shows tendency readout for the input signal and communication status.
  • Programming access can be blocked by assigning a password. The password is saved in the converter in order to ensure a high degree of protection against unauthorised modifications to the configuration.

 

 

 

4511 Modbus Communications Interface

Application:

  • The 4511 detachable display adds Modbus RTU RS485 serial communications to all current and future 4000/9000 series units
  • All individual unit operating parameters can easily and quickly be configured by using the Modbus communication or by using the front display menu
  • The 4511 display can be used to read the process signal, simulate the output signal, indicate sensor errors and internal device errors

Technical characteristics:

  • 4511 has full 4501 functionality for programming and display
  • RS485 Modbus RTU protocol
  • Multi-drop half-duplex connection via shielded RJ45 connector on top of module
  • Modbus parameters such as address, baud rate, stop bit(s) and parity bits are configured from, and stored on, the 4511 interface
  • 2.5kVAC galvanic isolation between serial wiring and 4000/9000 units

 

4512 Bluetooth Communications Interface

Application:

  • Program devices via Bluetooth using an iOS/Android device running the free PPS app (PR Process Supervisor).
  • Use PPS data for preventive maintenance.
  • All logged data can be exported in .csv format, for advanced data analysis off-site.
  • On-site analysis of real-time process data on an iOS/Android compatible device.
  • Off-site analysis of historic process data on a PC using PReset.

Technical characteristics:

  • PR 4512 runs Bluetooth 4.2, and requires a smart device with 4.0 or newer.
  • PPS is compatible with iOS and Android devices.
  • The PR 4512 automatically detects the device setting on the connected PR 4000 and 9000 device.
  • An internal battery energizes the 4512 real-time clock for at least 2 years, should the 4512 remain de-energized.
  • Typical data logging capacity is more than 30 days at 1 second intervals.
  • Easy to read dot matrix LCD display.
  • Fast pairing or safe pairing via two-factor authentication.

 

Android App for 4512 Interface

The image on the right links to the Google Play store to download the PR Electronics PPS application used to enables Android devices to connect to the Bluetooth Communications Interface. The app allows for the configuration, viewing of sensor live data and collection of logged data using the wireless Bluetooth connection.

 

 

If required, Omni Instruments will program a 9116, 4501, 4511, or 4512 to your specific requirements. Please contact us for details.

Additional information

Select:

, , ,

Product

Ref

Price

Product Description

More Info

Downloads

9116B1

£365.00

9116B1 Universal Converter IS Interface 4-20mA and Relay outputs. Max loop voltage <28vDC. Input Pt100, Pt1000, Ni100, TC types, RTD types, Potentiometer, Linear resistance, NAMUR, 0…12 VDC. Output 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA, Relay(s), 2-wire 4-20 mA

9116B2

£368.00

9116B2 Universal Converter IS Interface 4-20mA and Relay outputs. Max loop voltage <21.4vDC. Input Pt100, Pt1000, Ni100, TC types, RTD types, Potentiometer, Linear resistance, NAMUR, 0…12 VDC. Output 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA, Relay(s), 2-wire 4-20 mA.

5910EEX

£16.89

CJC (Cold Junction Compensation) Connector. Improves temperature accuracy readings

4510

£69.00

4510 Programming display for systems 4000 and 9000 devices. Each 4510 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status. The 4510 display clicks onto the front of the units are is interchangeable between units for programming or display.

4511

£92.85

4511 Programming display and Modbus RTU protocol interface for systems 4000 and 9000 devices. Each 4511 display can be used on several different units to allow for modification/transfer of operation parameters or on an individual unit as a fixed display for readout of process data and status, plus as an RS485 Modbus RTU connection to a local network. The 4511 display clicks onto the front of the device and an RJ45 connector on top of the unit allows for connection to a Modbus network.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Enquire now