420.0100
ThermoAir Pro Directional (V) Thermal-Electric Directional Anemometer. Air Velocity Range: 0.015-1m/s with a 0-1V Output. Accuracy ±1.0% of full scale. Sensing head 8mm diameter, handle 15mm diameter, probe length 300mm. The required diameter of the retraction opening for the probe is 9mm. The sensor can be used at temperatures from..
4222
Programmable Universal I/f Converter...
4225A
4225A Programmable Universal f/f & f/I Converter. Outputs: 1 Analogue (Current: 0-20, 4-20, ±10mA, or ±20mA; Voltage: 0-5, 1-5, 0-10, 2-10, ±5, ±10vDC) and 1 Relay Output (Setpoint, Window, Sensor error, Latch, Power and Off). Power Supply: 21.6-253vAC or 19.2-300vDC..
4249276
Liquid level float switch, overhead suspension type, with 5 metres of cable, contact rated max Switching Voltage 250V AC, 110V DC. Maximum current 10 amps...
431.13.11.04.62.20.U
PTM485 Programmable pressure transmitter, 316L Stainless Steel housing and diaphragm, Viton seals. Range 0 to 40 BarG [programmable between 10 to 40 Bar]. ¼" BSP pressure connection. Electrical connection - Binder 723 7-pin. Output RS485, 4-20mA. Accuracy ±0.25%. Temperature range 0 to 70°C...
5104A–A
PR Electronics 5104 programmable transmitter, 24-230 VAC/DC power supply, 1 channel with 0-20, 4-20mA, voltage input & mA or voltage output. See datasheet for Input & Output options...
5105B-A
Ex-Isolated Driver, 1 Channel, ATEX, II (1) GD, mA, V, 24...230 VAC/DC..
5106AB-A
Hart Transparent Repeater, 1 Channel, 4...20 mA, 24...230 VAC/DC..
5114A-A
Single channel 5114A programmable transmitter. Single channel unit for RTD, TC, mV, linear resistance, mA and V inputs, producing a (0)4-20mA, 0-10vDC output. 3-port 3.75 kVAC galvanic isolation. Can be mounted vertically or horizontally on a DIN rail. Power Supply 21.6 to 253vAC or 19.2 to 300vDC...
5115A
5115A Signal Calculator. Redundancy measurement of 2 inputs, duplication of input signals or signal calculations of inputs. Unit will accept RTD, Ohm, TC, mA, mV, V input signals. Power supply 21.6 - 253 vAC or 19.2 - 300vDC with 0-20mA or 0-10vDC output...
5116A
5116A Universal programmable transmitter, 24~240VAC/DC, 2 Relays and retransmit output...
5131A-A
Single channel 2-wire programmable transmitter with a 7.5-35vDC power supply. Please specify the required inputs RTD, TC, R, mA, mV or V. Output 4-20mA...
5202B1
5202B1 2 Channel Pulse Isolator with 2 NPN Outputs. Units will accept NAMUR or mechanical contact inputs. Power supply 21.6 - 253 vAC or 19.2 - 300vDC. Units are suitable for Hazardous Area Installations, ATEX II (1) GD...
5203B–1
Ex Solenoid / Alarm Driver, 1 ch., ATEX II (1) GD, NPN, PNP, Switch, 24...230 VAC/DC..
5223A1
Standard programmable f/I-f/f converter with a 24-230vAC/DC power supply. Analogue output mA, mV, V and NPN/PNP output...
5225A1
Standard programmable f/I-f/f converter with a 24vDC power supply. Analogue output mA, mV, V and NPN/PNP output...
5331A3B
PR 5331A3B 2-Wire Programmable Transmitters. Inputs: -12 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 5000Ω. Output: 4-20mA. Accuracy ≤±0.05% of span. Response Time: 1 to..
5333A
PR 5333A 2-Wire Programmable Transmitters. Inputs: RTD (2 or 3 Wire) Range -200 to +850°C; Linear Resistance – 0 to 10,000Ω. Output: 4-20mA. Accuracy ≤±0.1% of span. Response Time: 0.33 to 60 Seconds. Power Supply 8-35vDC @ 0.8W Max. Namur NE43. Approvals: Zone 2, (ATEX, IECEx & INMETRO); Zone 2..
5334A3B
PR 5334A3B 2-Wire Programmable Transmitters. Inputs: -12 to 150mV; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr);. Output: 4-20mA. Accuracy ≤±0.05% of span. Response Time: 1 to 60 Seconds. Power Supply 7.2-35vDC @ 0.8W Max. 1.5kVAC Galvanic Isolation. Namur NE21, NE43. Approvals: Zone..
5335A
PR 5335A 2-Wire Programmable Transmitters with HART 5 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 Protocol...
5337A
PR 5337A 2-Wire Programmable Transmitters with HART 5/7 Protocol. Inputs: -800 to 800mV; RTD (2, 3 or 4 Wire) Range -200 to +850°C; Thermocouples (Type B, E, J, K, L, N, R, S, T, U, W3, W5, Lr); Linear Resistance – 0 to 7000Ω. Output: 4-20mA & HART 5 or..
5343A
PR 5343A 2-Wire Programmable Level Transmitters. Inputs: Potentiometer – 0 to 100kΩ. Output: 4-20mA. Accuracy ≤±0.1% of span. Response Time: 1 to 60 Seconds. Power Supply 8-35vDC @ 0.8W Max. Namur NE43. Approvals: Zone 2, (ATEX, IECEx & INMETRO); DNV & EAC Certification. Operating Temp: -40 to +85°C...
5531A
4-digit LCD display 48 x 96 mm ~ Loop-powered, Easy scalable from front keys, Backlight..
5714 Universal Indicator
LED-display, 48 x 96 mm. Universal input for V, mV, mA, thermocouples and PT100 sensors. Programmable via front keys. Galvanic isolation, 2.3 kVAC. Relay and analogue output. Universal voltage supply (24-230 V AC/DC), Protection IP65..