17155162
The replacement DualSense pack of Nitrogen Dioxide sensors for the Tango TX1-4 Gas Detector has a measuring range of 0-150 ppm with a 0.1 ppm resolution. The DualSense pack comes with 2 NO2 sensors...
CA-11/16
Solsum 10.10F Solar Regulator. This regulator is suitable for solar panel installations with a maximum 240 Watts @ 24vDC (120W @ 12vDC) and a maximum current of 10A. The regulator provides protection to the batteries from over charging and reverse charging during darkness. LED indicators show charging status, operation and..
CMC-N16-LOGGER
Licence Key to allow a CMC-N16 unit to log data...
E2-05A
5m Anthracite extension cable for HC2 Probe with connector...
LOGBOX-PSU-USA
Mains Power Adaptor, Mains AC - 12V @ 1.25A - US Plug..
17124975-4
Replacement MX6 Sensor for Nitrogen Dioxide (NO2). Range 0 to 150ppm, Resolution 0.1ppm. Response time 7 seconds (T50)..
17155163
The replacement DualSense pack of Sulphur Dioxide sensors for the Tango TX1-5 Gas Detector has a measuring range of 0-150 ppm with a 0.1 ppm resolution. The DualSense pack comes with 2 SO2 sensors...
MTN/MS003
Quick-fit to M10 male stainless steel stud adapter. Provides a high rigidity connection but with reduced high frequency response...
17124975-5
Replacement MX6 Sensor for Sulphur Dioxide (SO2). Range 0 to 150ppm, Resolution 0.1ppm. Response time 5 seconds..
17155823
The replacement DualSense pack of Carbon Monoxide, low hydrogen interference sensors for the Tango TX1-G Gas Detector. The CO/H2 Low sensor has a measuring range of 0-1000 ppm with a 1 ppm resolution. The Cells use two electrodes and a special catalyst with a lower sensitivity to Hydrogen to detect..
17124975-6
Replacement MX6 Sensor for Ammonia (NH3). Range 0 to 500ppm, Resolution 1ppm. Response Time 21 Seconds (T50)..
17124975-7
Replacement MX6 Sensor for Chlorine (Cl2). Range 0 to 50ppm, Resolution 0.1ppm. Response Time 6 Seconds (T50)..
17124975-8
Replacement MX6 Sensor for Chlorine Dioxide (ClO2). Range 0 to 1ppm, Resolution 0.01ppm. Response Time 7 Seconds..
17124975-9
Replacement MX6 Sensor for Phosphine Low (PH3). Range 0 to 5ppm, Resolution 0.01ppm. Response Time 5 Seconds (T50)..
133-220
General Purpose K-Type Penetration Probe, 100mm x 3.3mm diameter. Supplied with 3 metre PTFE Insulated Lead and a K Therm MiniPlug connector. Probe Temperature Range: -75 to +250°C, Response Time: <5 Seconds. Part Ref 133-220..
17124975-A
Replacement MX6 Sensor for Hydrogen Chloride (HCl). Range 0 to 30ppm, Resolution 0.1ppm. Response time 17 seconds (t50)..
3462523
2 Metre Cable with IP67 M12 Mating Connector. Colour Coding: Pin 1 - Brown, Pin 2 - White, Pin 3 - Blue, Pin 4 - Black...
551-73
500ml Zero Solution for Dissolved Oxygen Electrode..
888257
Quasar 900 Series Extended Commissioning Kit, Covers Methane, Propane and Ethylene. The kit includes an alignment tool, a magnetic mode selector, 6 functional check filters (Part No. 888260-1, 88260-2, 888260-3, 888260-4, 888260-5 and 888260-6), socket keys and non-EX USB/RS485 harness converter kit.. Used for System installations and periodical function tests..
B-514
DC power cable for GL Series data loggers. Cable is 2m long with flying leads on one end and power adaptor on the other...
CAL-SCS-THERMOAIR
SCS Calibration Certificate for ThermoAir anemometers and Thermoelectric anemometers fitted to ThermoAir display units. Price covers a 5 point calibration..
CAL2AXISROTATE
Calibration 2 Axis - Rotate (Wind Tunnel). The calibration procedure involves a fixed wind velocity and the unit is rotated from 0 to 360 Degrees in 180 separate steps, providing a reading every 2 Degrees. The calibration certificate then compares the fixed wind velocity of the wind tunnel to the..
CALCERT B
Recalibration Certificate for Infrared Sensors, PyroMini, PyroCouple and PyroPen. UKAS traceable certificate showing the measured temperature at three points across the sensors temperature range...
CALPROB
2 Point calibration of oven temperature probe...