BM25 Replacement Sensor Cells
The BM25 gas detectors include field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration. Up to 5 sensor can be installed, each in one or more specific location...
MX6 Replacement Sensor Cells
The MX6 gas detectors include field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration. Up to 5 sensor can be installed, each in one or more specific location...
N10115
MSR Bluetooth BLE Receiver Base Station. The BLE receiver box acts a gateway which allows the automatic data transfer of several Bluetooth MSRxxxWD data loggers to the MSR SmartCloud...
N10130
WiFi Router for MSR175W2D. FRITZ!Box 6820 LTE WLAN access point (access to mobile network)..
N1100 Universal Process Controller
N1100 Universal Process Controller with dual LED Display suitable for Thermocouple, PT100, 4-20mA and 0-5vDC inputs. Dimensions 48 x 48 x 110mm, operating temperature 0 to 55 C. Optional 24vDC Power Supply and Relay Outputs. Programmable via front keypad and USB interface with NConfig software...
N1100 Universal Process Controllers
The N1100 Series of universal process controllers provide a wide range of features that are needed for the vast majority of industrial processes. The N1100 accepts J, K, T, N, R, S Type Thermocouples, PT100 RTD, 4-20mA, 0-50mVdc or 0-5vDC inputs and features two SPST relays (option available for 1..
0362700
CMF 1 Mounting fixture has a 88mm diameter round plate with a non-removable mounting rod of 16mm diameter and 350mm long. Can be mounted to a pole or wall with the CMB 1 mounting bracket...
5200-12S-BR
Set of two blocking rings for resealing pipework when flow meters are removed. Suitable for CDI-5200-12S flow meters..
CLAN-3524-XF
cLAN Ethernet Data Logger. 2 RS232/485 Port for connecting serial devices to embedded Modbus Master for I/O Expansion, NMEA0138 or Gill Instruments WindSonics and MetPak weather stations. 16 Configurable digital inputs (8 as pulse inputs), 8 configurable analogue inputs (4-20mA, 0-1V or 0-10V) and 8 digital outputs. Event logging and..
FCS2151-SP-420E
Omni C Series Current Transducer. Selectable current ranges: 0-100, 0-150 or 0-200A with a 4-20mA output, accuracy 1%FS. Power Supply 15 to 42vDC (loop powered). Suitable for single phase circuits with a frequency 40-400Hz. Isolation voltage 2000V. Split core transducer with a 20 x 22mm conducer hole. Certification: CE, UL..
GRD3534-XF-4GM
GPRS RTU, 1 USB Port, 8 analogue inputs, 0-1v 0-10v/4-20mA, 16 digital channels, configurable as digital state or pulse inputs (Max 8 at 1kHz), 8 channels selectable via jumpers as outputs. Dual RS485/232 ports. Embedded Modbus Master on RS232/RS485. Up to 100 registers (4x, 3x, 0x and 1x Modbus registers)..
LFT/4-20mA
Alternative 4-20mA output option...
N321R Electronic Thermostat
N321R Electronic Thermostat with Defrost Cycle, 3 digit LED Display and one control Relay SPDT (1 HP 250vAC / 1/3 HP 125vAC). Suitable for PT100, PT1000, NTC and Thermocouple temperature inputs. Front-panel with IP65 protecton. Dimensions: 75 x 33 x 75 mm...
PB-6007-1M5
PT100 Oven Temperature Probe for use with the TGP-4104 and TV-4104 data logger. The stainless steel probe is 150mm long and 6mm in diameter with a 1.5m PTFE cable. Temperature range -50 to 250°C with a 20 second response time in water...
RODENDM12X1.75
Rod End Bearing to align extraneous forces through the principle axis of a load cell. M12 x 1.75 Male Right-hand Thread Construction: Hard Chromium/PTFE composite/Elgoglide sliding contact surface, with Zinc plating for corrosion resistance. Rod Eye 12mm diameter. Designation: GAR12 UK..
SC1000A
SC1000A Split core, self powered, AC current sensor. Current range 0-1000 Amps, output 0-5vDC. Accuracy ±1% of reading from 10% to 100% of full scale. Dimensions 6.1" x 6.0" x 1.25" with a 4" square window and 8 ft signal cable. Operating temperature -20 to +55°C...
VIM-3010
Voltage Input Module for RTR505B(L), TR55i-V and RTR505-V(L) Remote Units. Cable connects via a 4 Terminal cable insertion terminal, AWG22-28, strip length 9 to 10mm. Measurement Range: -0-22V. Resolution: Up to 400mV, 0.1 mV; Up to 800mV, 0.2 mV; Up to 999mV, 0.4mV; Up to 3.2V, 1 mV; Up to..
5200-12C-BR
Set of two blocking rings for resealing pipework when flow meters are removed. Suitable for CDI-5200-12C flow meters..
PB-6007-3M
PT100 Oven Temperature Probe for use with the TGP-4104 and TV-4104 data logger. The stainless steel probe is 150mm long and 6mm in diameter with a 3m PTFE cable. Temperature range -50 to 250°C with a 20 second response time in water...
NA5Plus Series
NA5Plus Series bar graph.with numerical LED display. Digit height: 7mm, indication range: -1999...9999, multi-colour bar graph, 88 mm length, 55 segments (3-colour), 29 segments (7-colour)..
NA6Plus Bar Graph Display
NA6Plus Series Programmable LED display for dual channel inputs with a multicolour bargraph and numerical readouts. Suitable for measuring 0-60mV, 0-600V, 0-20mA, 0-5A, resistance, RTD or Thermocouples. Power supply 95-253VAC or 20-40VDC..
0362703
CMF 4 Mounting fixture has a 280mm diameter plate with a non-removable mounting rod of 20mm diameter and 350mm long. Can be mounted to a pole or wall with the CMB 1 mounting bracket. Suitable for ventilated radiometers...
PB-6007-5M
PT100 Oven Temperature Probe for use with the TGP-4104 and TV-4104 data logger. The stainless steel probe is 150mm long and 6mm in diameter with a 5m PTFE cable. Temperature range -50 to 250°C with a 20 second response time in water...