Power Logger for AC Current, Voltage, kWh

Power Logger for AC Current, Voltage, kWh

Quick Overview

Utilizing the SQ2010 data logger, along with AC current clamps, AC voltage sensors and kWh sensors this system can be used to monitor electrical power consumption on single phase or multiphase supplies.
View Options

Details

Supplied pre-programmed and fitted with sensors suitable for your site.

The logger can be started and stopped using the buttons on the front so a PC is not required on site to set the unit up.

All data can be downloaded via USB cable to a laptop using the SquirrelView software supplied, and data can be viewed in graph and table format, and exported to MS Excel.

Key Features

  • Compact, portable data logger
  • Powered from internal cells, external PSU or via USB connection
  • 8 universal analogue inputs for AC current or AC voltage sensors
  • 16 derived/calculated channels
  • 2 alarm outputs
  • 2 pulse counter inputs for kWh sensors
  • Configured via large easy-to-read graphical display
  • Stores up to up to 1.8 million readings
  • Supplied with SquirrelView set-up/download and export software
  • Other parameters such as temperature, RH, flow etc can be measured.

Sensors supported

  • AC Current 0-100, 0-150, 0-200 amps
  • AC Voltage to 600 VAC
  • kWh sensors
  • PT100 and thermocouples for temperature measurement
  • Fuel level sensor for diesel generator monitoring
  • Up to 10 readings per second on 1 channel
  • Up to 1 reading per second on 2 or more channels
  • USB communications

 

Alternative and additional sensors are available for additional monitoring, please contact for further options if you don't see the options you required listed below.

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
SQ16 Data Logger
SQ16
SQ16
Squirrel SQ16 Data Logger, 8 differential or 16 single ended channels suitable for 2-Wire PT100, Thermocouples, V and mA inputs. 32 bit resolution, 4GB internal memory (200 million readings), 8 digital inputs and 4 digital alarm outputs. USB to PC connection & Bluetooth wireless interface, complete with SquirrelView, AA Batteries, signal connectors, screwdriver and USB to PC cable.
View FileDatasheet
   Size: (441.66 KB)
£1,425.00
or call us for a quote
 
SQ Series Mains Power Supply
MPU12V
100-240VAC 50/60Hz Mains Adapter supplied with 4-single fit mains plugs for UK, Euro, US and AUS/NZ. Powers SQ Data Loggers only. Output 12vDC 1.0A
£52.00
or call us for a quote
ENCL-PORT-1450
Portable 1450 Peli case, colour black. Internal dimensions: 376 x 263 x 152mm (L x W x H), weatherproof to IP67 and includes foam insert. Omni Instruments can also provide these peli cases customised to suit your own specific requirements, please contact us directly to discuss your requirements.
£200.53
or call us for a quote
 
Current Clamps
SC100A
SC100A Split core, self powered, AC current sensor. Current range 0-100 Amps, output 0-5vDC. Accuracy ±1% of reading from 10% to 100% of full scale. Dimensions 2.6" x 2.3" x 1.25" with a 0.5" square window and 8 ft signal cable. Operating temperature -20 to +55°C.
View FileData Sheet
   Size: (90.49 KB)
£201.00
or call us for a quote
SC200A
SC200A Split core, self powered, AC current sensor. Current range 0-200 Amps, output 0-5vDC. Accuracy ±1% of reading from 10% to 100% of full scale. Dimensions 3.3" x 3.0" x 1.25" with a 1" square window and 8ft signal cable. Operating temperature -20 to +55°C.
£201.00
or call us for a quote
SC500A
SC500A Split core, self powered, AC current sensor. Current range 0-500 Amps, output 0-5vDC. Accuracy ±1% of reading from 10% to 100% of full scale. Dimensions 4.1" x 4.0" x 1.25" with a 2" square window and 8ft signal cable. Operating temperature -20 to +55°C.
£258.12
or call us for a quote
SC1500A
SC1500A Split core, self powered, AC current sensor. Current range 0-1,500 Amps, output 0-5vDC. Accuracy ±1% of reading from 10% to 100% of full scale. Dimensions 5.4" x 4.7" x 1.25" with a 4" square window and 8ft signal cable. Operating temperature -20 to +55°C.
£223.28
or call us for a quote
 
Voltage Sensors
SV300
AC voltage sensor model SV300. Voltage range 0-300vAC, frequency range 48-65Hz, accuracy ±1% of full scale. Suitable for 24, 120 and 240vAC circuits. AC voltage sensors should always be mounted and wired in a box, panel or suitable enclosure.
£243.82
or call us for a quote
SV600
AC voltage sensor model SV600. Voltage range 0-600vAC, frequency range 48-65Hz, accuracy ±1% of full scale. Suitable for 120, 240 and 480vAC circuits. AC voltage sensors should always be mounted and wired in a box, panel or suitable enclosure.
£283.48
or call us for a quote
WH-2100
WH-2100 watt hour sensor. Range 0-100 Amp, input voltage 208-230VAC ±10%, output 1 pulse per 10 watt hours.
View FileDatasheet
   Size: (430.04 KB)
£331.97
or call us for a quote
WH-2200
WH-2200 watt hour sensor. Range 0-200 Amp, input voltage 208-230VAC ±10%, output 1 pulse per 10 watt hours.