Description
The TV-4810 is an AC Current Data Logger with a clip-on current clamp. It is ideal for monitoring mains current consumption and for determining when equipment has a higher current drain. This accurate and reliable unit measures current from 0 to 200A AC and is suitable for conductor sizes up to 20mm.
Features
- Logger with clip-on current clamp
- Range 0 to 200A AC Current
- 4 Digit Display
- 2 user programmable alarms
- 30,000 reading memory
- High reading resolution of 10mA
- Fast data offload
- User-replaceable battery
Specifications
| Physical Specifications | Sensor Specifications | ||
| Total Reading Capacity: | 30,000 Readings | Sensor Type: | Current Clamp (ACS-0003) |
| Memory Type: | Non-Volatile | Measuring Range: | 0-200A AC Current |
| Trigger Start: | Magnetic Switch | Frequency Range: | 40 to 10kHz |
| Delayed Start: | Relative/Absolute (up to 45 days) | Reading Resolution: | 10mA |
| Stop Options: | When full After n Readings Never (overwrite oldest data) |
Accuracy: | 0.5A to 10A (5% of reading ±0.5A) 10A to 40A (3% of reading ±0.5A) 40A to 200A (2% of reading ±0.5A) |
| Reading Types: | Actual, Min, Max | Cable Length: | 1.5m |
| Logging Interval: | 1 sec to 10 days | Conductor Size: | 20mm |
| Alarms: | 2 fully programmable; latchable | Current Clamp Output: | 1mV/A |
| Operating Temperature: | -30 to +70°C | Operating Temperature: | -10 to 55°C |
| Case Dimension: | 85 x 77 x 35mm (60mm Diameter) | Display Resolution: | 0.1A |
| Weight: | 100g | Weight: | 180g |
*The measuring time between 200 and 240A should be limited to 10 minutes on, followed by 30 minutes off.
You will also require Tinytag Explorer software and a CAB-0007-USB data download cable to use these loggers. These are available separately or as a pack (SWPK-7-USB).