omni instruments | sensors and data acquisition equipment

Sales & Technical Support

Edit Content

TSM400-1-CP

TSM400-1-CP 1-Wire Carbon Dioxide and Pressure Sensor. CO2 Range 400 to 5,000ppm with 1 ppm Resolution. Atmospheric Pressure 10 to 1,200hPa with 1hPa Resolution. 1-Wire interface via screwless terminal block. IP20 Wall-Mounted enclosure with 81 x 81 x 30mm dimensions. Power Supply 4.5 to 26vDC (25mA, peak 150mA).

£132.11

Need help finding the right product?

Downloads

TSM400-1-CP Carbon Dioxide Sensor

Description

The TSM400-1-CP is a multi-parameter sensor that utilises the 1-Wire protocol to measure both carbon dioxide (CO2) concentration and atmospheric pressure. This sensor is designed for high accuracy and long-term stability, thanks to its use of digital sensing elements for both parameters. Notably, the atmospheric pressure sensing element is factory calibrated and does not require any subsequent re-calibration throughout its lifespan.

For carbon dioxide measurements, the TSM400-1-CP offers a convenient self-calibration feature, which can be performed by exposing the sensor to fresh air (around 400 ppm CO2 concentration). Housed in a slim plastic enclosure, the sensor is suitable for installation in standard flush-mounted or cavity wall boxes (ø68mm with 61mm installation openings). Given that elevated CO2 levels can negatively impact productivity, increase blood pressure, cause headaches, and even pose life-threatening risks in high doses, monitoring CO2 concentration with devices like the TSM400-1-CP is crucial for maintaining healthy environments in offices, workplaces, schools, and other public buildings.

Features

  • LED indicator for status of communication
  • Excellent long-term stability
  • Self-calibration on fresh air for the carbon dioxide measurements
  • Firmware update via the interface
  • Relatively low current consumption
  • The unique 64-Bit serial number for multi-sensors support

Applications

  • Environmental quality monitoring and assessment for offices
  • CO2 pollution monitoring
  • Indoor air quality systems
  • Safety Industries

Specifications

Parameter Carbon Dioxide Atmospheric Pressure
Measuring Range 400 to 5,000ppm 10 to 1,200hPa
Resolution 1ppm 1hPa
Accuracy ±(40ppm +5%) ±1.5 (750hPa @ 25°C)
±2.5 (300 to 1,100hPa @ -20 to +85°C)
Power Supply 4.5 to 26vDC
Current Consumption 25mA @ 5vDC (Peak 150mA @ 5vDC
Operating Range -20 to +60°C (5-95%RH Non-Condensing)
Dimensions: 81 x 81 x 30mm
Weight: 66g
Connectors: Screwless Terminal Block

 

Pinout of Connectors

Pin Description UTP Wire Colour
TERM Not Used
B- Not Used
A+ Not Used
GND Ground (Negative Supply) Green/White tracer
Orange/White tracer
+5÷30V Positive Power Supply Orange
1-W 1-Wire Data Green

SPL2_RJ11

£15.08

The SPL2_RJ11 cable can be used to connect the RJ11 connector to a wired network, or connect one of the 1-Wire sensor with screwless terminals to the RJ11 cables    