omni instruments | sensors and data acquisition equipment

Sales & Technical Support

Edit Content

SGW1-IA3-MMP Modbus Multiplexer

The SGW1-IA3-MMP is a multi-function device that allows multiplexing, conversion and data exchange between Modbus RTU and ASCII serial devices. The SGW1-IA3-MMP can be used to connect up to 3 Modbus Master devices to up to 3 Modbus Slave devices via 4 configurable RS232/RS485 ports. Each port can be independantly configurable as Modbus ASCII or RTU protocol, baud rate, RS232/485 or Master/Slave devices.

Need help finding the right product?

Downloads

SGW1 Modbus Multiplexer

Description

The SGW1-IA3-MMP is a Modbus communications multiplexer/converter over serial ports. It allows you to connect Modbus RTU/ASCII masters to Modbus RTU/ASCII slaves. Each of the serial devices can operate with Baud Rate, Data Bits, Parity, Bits Stop and different Modbus protocol type (RTU or ASCII). The SGW1-IA3-MMP orders the interrogations coming from the different masters assigning a priority according to the order of arrival of the different masters, and then sends them to the slaves.

The SGW1-13B0-00-IA3-MMP-CF can handle the RTS pin on port A for the activation of the transmission in devices, such as a radio modem. The RTS pin handles a timer, which will activate and deactive a serial port on at set time intervals. This option applies only to port A on the device.

As an additional function, the device allows the exchange of information between Modbus masters through the 1000-byte exchange memory that can be read and written by any of the connected masters.

Features

  • 4 Configurable RS232/RS485 ports
  • Up to 3 ports to connect Masters.
  • Up to 3 ports to connect Slaves.
  • The SGW1 can be used as a Modbus RTU to Modbus ASCII converter.
  • The SGW1 can be used as an RS232 to RS485 converter.
  • No need of registers tables.
  • DIN Rail mounting.
  • Wide range power supply, 10 to 30vDC.
  • Easy configuration.
  • Industrial pluggable terminal blocks.
  • USB Configuration

 

 

Specifications

Network Protocols: Modbus RTU or Modbus ASCII
Network Port: 4 RS232/RS485 Plug-in terminals + 1 USB Kind B
Configuration: USB Console
Modbus Masters: Up to 3 ports for Master devices
Modbus Slaves: Up to 3 ports for Slave devices
Power Supply: 10 to 30vDC, 200mA max.
Power Consumption: 70mA @ 12vDC or 40mA @ 24vDC
Operating Temp: -15 to 65°C
Dimensions: 100 x 22.5 x 112mm (H x W x D)

 

The SGW1-IA3-MMP provides a command console for configuration via a USB port. To access it, the SGW1-IA3-MMP must be connected to a PC and the Exemys Console program provide the interface to configure the device as required.

Product

Ref

Price

Product Description

SGW1-4B0-00-IA3-MMP

£364.72

Modbus Multiplexer and Converter. 4 x RS232/RS485 configurable ports, with 1 x USB port for configuration. DIN Rail mounted industrial enclosure with terminal blocks. Power supply: 10-30vDC, consumption 70mA @ 12vDC. Dimensions: 100 x 22.5 x 112mm. Operating Temperature: -15 to 65°C.

SGW1-13B0-00-IA3-MMP-CF

£387.40

Modbus Multiplexer and Converter. 1 RS232 port with RTS for control and 3 x RS232/RS485 configurable ports, with 1 x USB port for configuration. DIN Rail mounted industrial enclosure with terminal blocks. Power supply: 10-30vDC, consumption 70mA @ 12vDC. Dimensions: 100 x 22.5 x 112mm. Operating Temperature: -15 to 65°C.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.