Skip to content

omni instruments | sensors and data acquisition equipment

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Products
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket
Home / Load Cells / Load Cell Instrumentation / Programmable Load Cell Amplifier
Programmable Load Cell Amplifier

Programmable Load Cell Amplifier

The 2261 is a programamble load cell amplifier suitable for 4 wire bridge / strain gauge sensors. Both zero and span are programmable via the front key pad and the LED display allows easy setup.The unit also has NPN/PNP input for external taring and a regulated supply for standard transducers

View Options

Need help finding the right product?

CONTACT US

Downloads

Datasheet

2261 Programmable Load Cell Amplifier

  • Description

Description

Common specifications:
Supply voltage………………………………24 VDC ±20%
Internal consumption ………………….… 2.2 W
Max. consumption………………………… 7.2 W
Signal/noise ratio………………………….. Min. 60 dB
Signal dynamics, input ………………….. 17 bit
Signal dynamics, output…………… …… 16 bit
Updating time………………………………. 20 ms
Response time, programmable …….. … 0.06…999 s
Calibration temperature……………… …. 20…28°C
Temperature coefficient………………  … < ±0.01% of span / °C
Linearity error ……………………………… ≤±0.1% of span
Effect of supply voltage change……….   < ±0.002% of span/ %V
Auxiliary voltage:
Transducer supply………………………… 5…13 VDC
Load (max)…………………………………. 230 mA
EMC-Immunity influence…………… ….. < ±0.5% of span
Humidity ……………………………. …….. < 95% RH (non-cond.)
Dimensions (HxWxD)…………………….. 80.5 x 35.5 x 84.5 mm
Tightness……………………………..  …… IP50
Weight ……………………………………… 130 g

Electrical specifications – Input:
mV-input:
Measurement range ……………………… -40…100 mV
Min. measurement range (span)…….  .. 10 mV
Max. offset………………………………….. 70% of selec. max. value
Input in relation to supply gnd………   … > – 5 V and < +10 V
Max. cable resistance per wire…….  …. 15 Ω
Suppression of
transducer cable resistance …………… > 300
Input resistance…………………………… > 10 ΜΩ
Overrange…………………………………… 0…999% of selected measurement range
Digital input:
NPN………………………………………….. Pull up 24 VDC / 6.9 mA
PNP …………………………………………. Pull down 0 VDC/6.9 mA
Trig level low……………………………….. < 6 VDC
Trig level high………………………………. > 10.5 VDC
Pulse width…………………………………. > 30 ms

Electrical specifications – Output:

Current output:
Signal range ……………………………….. 0…20 mA
Min. signal range (span) ………………… 5 mA
Max. offset………………………………….. 50% of selec. max. value
Load (max.)…………………………… …… 20 mA / 600 Ω./ 12 VDC
Load stability ………………………………. < ±0.01% of span/100 .
Current limit…………………………………. < 23 mA
Voltage output through internal shunt:
Signal range ………………………………… 0…10 VDC
Min. signal range (span) …………….. …. 250 mVDC
Max. offset…………………………………… 50% of selec. max. value
Load (min.)…………………………………… 500 kΩ
Voltage limit ………………………………… < 11.5 VDC
Observed authority requirements: Standard
EMC 89/336/EEC, Emission ……   ……. EN 50 081-1, EN 50 081-2
Immunity……………………………………… EN 50 082-2, EN 50 082-1

Product

Ref

Price

Product Description

PR2261 mV Transmitter

2261

£369.26

PR2261 strain gauge/load cell amplifier, input range -40 to +100mV, Output 4 – 20mA or 0 – 10V. Power supply 24vDC. Supplied with DIN rail mounting base.
MORE INFO
Add to basket

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2025 | Design. Build. Host.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Call us on +44 (0)1382 443000

Enquire now