Common specifications:
Supply voltage………………………………24 VDC ±20%
Internal consumption ………………….… 2.2 W
Max. consumption………………………… 7.2 W
Signal/noise ratio………………………….. Min. 60 dB
Signal dynamics, input ………………….. 17 bit
Signal dynamics, output…………… …… 16 bit
Updating time………………………………. 20 ms
Response time, programmable …….. … 0.06…999 s
Calibration temperature……………… …. 20…28°C
Temperature coefficient……………… … < ±0.01% of span / °C
Linearity error ……………………………… ≤±0.1% of span
Effect of supply voltage change……….  < ±0.002% of span/ %V
Auxiliary voltage:
Transducer supply………………………… 5…13 VDC
Load (max)…………………………………. 230 mA
EMC-Immunity influence…………… ….. < ±0.5% of span
Humidity ……………………………. …….. < 95% RH (non-cond.)
Dimensions (HxWxD)…………………….. 80.5 x 35.5 x 84.5 mm
Tightness…………………………….. …… IP50
Weight ……………………………………… 130 g
Electrical specifications – Input:
mV-input:
Measurement range ……………………… -40…100 mV
Min. measurement range (span)……. .. 10 mV
Max. offset………………………………….. 70% of selec. max. value
Input in relation to supply gnd………Â Â … > – 5 V and < +10 V
Max. cable resistance per wire……. …. 15 Ω
Suppression of
transducer cable resistance …………… > 300
Input resistance…………………………… > 10 ΜΩ
Overrange…………………………………… 0…999% of selected measurement range
Digital input:
NPN………………………………………….. Pull up 24 VDC / 6.9 mA
PNP …………………………………………. Pull down 0 VDC/6.9 mA
Trig level low……………………………….. < 6 VDC
Trig level high………………………………. > 10.5 VDC
Pulse width…………………………………. > 30 ms
Electrical specifications – Output:
Current output:
Signal range ……………………………….. 0…20 mA
Min. signal range (span) ………………… 5 mA
Max. offset………………………………….. 50% of selec. max. value
Load (max.)…………………………… …… 20 mA / 600 Ω./ 12 VDC
Load stability ………………………………. < ±0.01% of span/100 .
Current limit…………………………………. < 23 mA
Voltage output through internal shunt:
Signal range ………………………………… 0…10 VDC
Min. signal range (span) …………….. …. 250 mVDC
Max. offset…………………………………… 50% of selec. max. value
Load (min.)…………………………………… 500 kΩ
Voltage limit ………………………………… < 11.5 VDC
Observed authority requirements: Standard
EMC 89/336/EEC, Emission ……Â Â ……. EN 50 081-1, EN 50 081-2
Immunity……………………………………… EN 50 082-2, EN 50 082-1