Skip to content

omni instruments | sensors and data acquisition equipment

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Products
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket
Home / Pressure Sensors / PL-692-4
PL-692-4

PL-692-4

PL-692-4 differential pressure transmitter suitable for liquids, steam and gases. Pressure range 0-4 BarD over a 4-20mA output with 11-33vDC power supply. IP65 stainless steel casing with a pair of 6mm compression pressure connection, ceramic Al2O3 (96%) diaphragm and 1.5m flying lead. Operating temperature range -15 to +85°C.

£313.20

Need help finding the right product?

CONTACT US

Downloads

Datasheet

PL-692 Differential Pressure Transmitter

  • Description

Description

The PL-692-4 is a robust and accurate differential pressure sensor with a 0-4 Bar range. A ceramic pressure sensor for stable and reliable measurements in liquid and non-aggressive gas applications. Its stainless steel IP65 housing ensures durability, with 4-20mA output options and easy installation via 6mm CuZn Nickel plated compression fittings and a 1.5m cable. The PL-692 is ideal for monitoring small pressure differential pressures for industrial processes or general low differential pressures across a wide temperature range.

Features

  • 4-20mA output
  • Supplied with 6mm o/d compression fittings
  • Easy installation and wiring
  • IP65 with 1.5m flying lead
  • High temperature stability
  • Suitable for water, steam or air
  • Robust construction

 

Specifications

Pressure Ranges: 0 to 4 Bar
Supply Voltage: 11 to 33vDC
Outputs: 4-20mA
Accuracy: ±0.03 Bar
Long Term Stability: ±0.02 Bar
Response Time: <5ms
Burst Pressure: 12 Bar Overload Pressure
Materials in Contact: Ceramic/Stainless Steel 1.4305 with the medium EPDM seal
Pressure Connection: 6mm Compression, CuZn Nickel Plated
Operating Temp: -15 to 85°C
Dimensions: 130 x 40mm
Protection: IP65
Conformity: EMC, CE & UKCA Marked

 

For differential pressure measurement at high line pressure, it is recommended that the pressure sensor should be installed with a valve in each line plus a shunt (bypass) valve across the high (P1) and low (P2) pressure ports. This ensures that any potential overload on either P1 or P2 doesn’t exceed the maximum permitted.

Valve C should be open and valves A & B closed whenever the system is first being wetted or pressurised. Valves A & B should then be
opened slowly to avoid hammering. Valve C can then be closed and the system is operating.

If the pressure sensor is to be removed from the system, valve C must be opened first, the valve A & B can then be closed.

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2026 | Design. Build. Host.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Call us on +44 (0)1382 443000

Enquire now