Description
The MSR175 stand-alone data logger uses high-resolution sensors to continuously record what happens to your goods during transportation. The logger data can then be analysed very accurately – be it in order to ascertain damage or to improve transport packaging – using the “MSR ShockViewer” software.
Collecting data for secure transportation
The two 3-axis acceleration sensors integrated in the MSR175 have working ranges of ±15 g and ±200 g. They record shocks and jolts at a measurement frequency of up to 6,400 measurements per second. The installed memory of the logger is capable of storing over 2 million measured values, which is sufficient for more than 1,000 shocks. In addition, the MSR175 data logger measures and records temperature profiles from -20° to +65 °C. Additionally, a second type variant of this data logger is available with internal humidity, pressure and light sensors.
Easy-to-use pc software: Thanks to the new MSR175 Dashboard software, preparing the MSR175 for its mission and reading its measured data via USB is very easy. The data can be analysed and clearly presented in a chart using the intuitive MSR ShockViewer software. In the process, you can analyse critical events at a glance and document them conclusively in a report; a frequency analysis facilitates identifying the causes of shock events.
Sensor Specifications
Measured Parameters | Working Range | Accuracy | Measurement/Storage Rate |
3-axis acceleration | ±15g and ±200g (-20…+65 °C) |
±0.15g (+25 °C) up to 15g ±2 g, up to 100g ±5g, up to 200g ±10g (at +25 °C) |
up to 6400/s (±15 %) |
Temperature | -20…+65 °C | ±0.5 °C (-10…+65 °C) | every 10 min. |
Relative humidity | 0…100%RH -20…+65 °C |
±2%RH (10…85%, 0…+40 °C) ±4%RH (85…95%, 0…+40 °C) |
every 10 min. |
Air pressure absolute | 0…2000 mBar absolute -20…+65 °C |
±2.5 mBar (750…1100 mBar absolute, +25 °C |
every 10 min. |
Light | 0…83,000 lx | max. sensitivity at 500 nm | every 10 min. |
General Specifications
Housing: | Design housing PC, encapsulated, IP67 |
Size & Weight: | 47 x 16 x 54 mm (W x H x L), approx. 28 g |
Memory capacity: | Over 2,000,000 measurement values |
Medium: | Air, various liquids |
Colour: | Amber |
Key: | Start measurement/retrieve status |
Power supply: | LiPo-battery 230 mAh, charged via the USB connection, recording period up to 8 weeks |
Options: | Charging station (USB hub) for 7 MSR175 (item number B47002) |
Interface: | USB |
PC software: | free MSR ShockViewer basic version extensive MSR ShockViewer pro version |
Operating Temp: | -20…+65 °C |
Storage Conditions: | +5…+45 °C (ideal storage condition for the battery) 10…95 % relative humidity, non-condensing |
Standards: | The MSR175 complies with EU-Directives RoHS/WEEE. |