LEX 1 Digital Manometer is a highly precise pressure indicator with available pressure ranges up to 1000 Bar. The LEX 1 is a micro-processor controlled, digital pressure measuring instrument with integrated max.- and min- function for testing and calibration purposes. Standard accuracy is 0.05%FS with optional precision of 0.025%FS and 0.01%FS.

Need help finding the right product?

Downloads

LEX 1 Digital Manometer

Description

Features

  • 5 digit LCD, top display showing actual and lower display showing min/max readings
  • 13 selectable pressure units, including Bar, PSI and hPa.
  • Insulated piezoresistive pressure sensor encapsulated in an oil-filled metal housing
  • High Accuracy of up to 0.01 %FS, 0.05% standard
  • RS485 bus interface for communication with up to 128 devices
  • 3V internal battery, type CR2430, up to 2,000 hours continuous operation
  • IP65 rated
  • Units are supplied with a 5 point calibration certificate

Specifications

Material in contact with Media

Display Housing: Faradex AS-1003
Pressure Connection: Stainless Steel AiSt 316L
Pressure Transducer: Stainless Steel AiSt 316L
Seal (Internal): FKM (Viton Type A)
Seal  (External): FKM (Viton Type A)

Pressure Ranges

Relative Pressure (PR)
Absolute Pressure (PA, PAA)
Over Pressure Resolution
-1 to +1 Bar 0 to 2 BarA 8 Bar 0.1mBar
-1 to +3 Bar 0 to 4 BarA 8 Bar 0.1mBar
-1 to +6 Bar 0 to 7 BarA 20 Bar 1mBar
-1 to +10 Bar 0 to 11 BarA 20 Bar 1mBar
-1 to +16 Bar 0 to 17 BarA 90 Bar 1mBar
-1 to +30 Bar 0 to 31 BarA 90 Bar 1mBar
0 to 61 BarA 300 Bar 1mBar
0 to 101 BarA 300 Bar 10mBar
0 to 161 BarA 600 Bar 10mBar
0 to 300 Bar 600 Bar 10mBar
0 to 400 Bar 800 Bar 20mBar
0 to 700 Bar 1100 Bar 50mBar
0 to 1000 Bar 1100 Bar 100mBar

General Specifications

Battery: 3V battery, CR2430
Battery Life: Approx. 2000 Hours
External Supply: 8-28vDC
External Interface: RS485 Half-Duplex
Interface Measuring Rate: 30 measurements per second
Pressure Connection: 1/4″ BSP, Others on request
Diameter x Height x Depth: 76 x 148 x 55mm approx
Weight: 335g

 

Accuracy ±0.05 %FS, with KELLER test report ex works (standard)
Keller uses pressure sources to calibrate its products that are at least four times more accurate than the product
to be tested. This enables us to produce products in our factory with an absolute accuracy of up to ±0,05 %FS.

Precision ±0.01 %FS / 0.025 %FS, with KELLER test report ex works
Additional measurement work and selection of a specific pressure transducer means that optimum repeatability is guaranteed for selected pressure transmitters and digital manometers. Owing to the residual measurement uncertainty of the pressure sources used at its factory, KELLER cannot provide any verification of measurement accuracy at scales below ±0.05 %FS for these ultra-precise devices. KELLER therefore uses the term “precision” to denote the ability of a pressure transmitter or manometer to repeat measured values within a tolerance of 0,01 %FS based on the pressure sources used at the factory.

Accuracy ±0.01 %FS with DakkS (German accreditation body) certificate, issued by an external accredited calibration laboratory
By calibrating the zero point and performing amplification via the digital interface, an accredited calibration laboratory (ilac.org) can adapt ultra-precise KELLER products to their more accurate pressure sources and record the results. External calibration to an accuracy of up to ±0.01 %FS is performed in accordance with the guidelines set out by the German Calibration Service (DKD) and is conducted under reference conditions without any consideration of long-term effects.

 

 

LEX1-4BARA-0.05%-1/4BSP

£755.00

LEX 1 Digital Manometer with digital display for pressure and Min/Max values. Range 0 to 4 BarA (vacuum reference pressure) with 0.1mBar resolution and ±0.05%FS accuracy. Pressure connection: Stainless Steel ¼” BSP male connection with Viton O ring. Rear mating socket for 8-28vDC Power Supply and RS485 Modbus Output. Internal battery for up to 2,000 Hours continuous use. Units supplied with plastic case, CR2430 battery and 5 point calibration certificate.

LEX1-30BAR-0.05%-1/4BSP

£755.00

LEX 1 Digital Manometer with digital display for pressure and Min/Max values. Range -1 to 30 Bar (Relative pressure reference) with 1mBar resolution and ±0.05%FS accuracy. Pressure connection: Stainless Steel ¼” BSP male connection with Viton O ring. Rear mating socket for 8-28vDC Power Supply and RS485 Modbus Output. Internal battery for up to 2,000 Hours continuous use. Units supplied with plastic case, CR2430 battery and 5 point calibration certificate.

LEX1-300BAR-0.05%-1/4BSP

£755.00

LEX 1 Digital Manometer with digital display for pressure and Min/Max values. Range 0 to 300 Bar (Absolute pressure reference) with 0.01 Bar resolution and ±0.05%FS accuracy. Pressure connection: Stainless Steel ¼” BSP male connection with Viton O ring. Rear mating socket for 8-28vDC Power Supply and RS485 Modbus Output. Internal battery for up to 2,000 Hours continuous use. Units supplied with plastic case, CR2430 battery and 5 point calibration certificate.

LEX1-700BAR-0.05%-1/4BSP

£760.00

LEX 1 Digital Manometer with digital display for pressure and Min/Max values. Range 0 to 700 Bar (Absolute pressure reference) with 0.05 Bar resolution and ±0.05%FS accuracy. Pressure connection: Stainless Steel ¼” BSP male connection with Viton O ring. Rear mating socket for 8-28vDC Power Supply and RS485 Modbus Output. Internal battery for up to 2,000 Hours continuous use. Units supplied with plastic case, CR2430 battery and 5 point calibration certificate.

LEX1-1000BAR-0.05%-1/4BSP

£760.00

LEX 1 Digital Manometer with digital display for pressure and Min/Max values. Range 0 to 1,000 Bar (Absolute pressure reference) with 0.1 Bar resolution and ±0.05%FS accuracy. Pressure connection: Stainless Steel ¼” BSP male connection with Viton O ring. Rear mating socket for 8-28vDC Power Supply and RS485 Modbus Output. Internal battery for up to 2,000 Hours continuous use. Units supplied with plastic case, CR2430 battery and 5 point calibration certificate.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Enquire now