Skip to content

omni instruments | sensors and data acquisition equipment

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Products
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket
Home / Voltage & Current Sensors Energy Monitoring Systems / Energy Monitoring Systems / GSKIN U-Value & Heat Flux Measurement Kit
GSKIN U-Value & Heat Flux Measurement Kit
GSKIN U-Value & Heat Flux Measurement Kit - Image 2

GSKIN U-Value & Heat Flux Measurement Kit

GSKIN U-value Kit are a plug and play solution to allow for the remote measurement of U-value (W/(mK)), heat flux (W/m²), and 2 temperatures (°C). The kit combines a GSKIN heat flux sensor with a custom designed miniature MSR logger and two external temperature sensors on 1 & 5m cables. The logger has an internal memory for up to 2 million readings and can be left to log the data, or in a live operation mode for a real time investigation. Each kit consists of a logger, sensors, USB cable, carry case and software. The logger is configured with the calibration data for the individually supplied sensors.

View Options

Need help finding the right product?

CONTACT US

Downloads

Datasheet

GSKIN U-Value Kit

  • Description

Description

Features

  • Calibrated plug and play solution
  • Measurement of U-Value (W/(m²K)), heat flux (W/m²), and 2 temperatures (°C)
  • Compatible with standard ISO 9869 and ASTM C1046/ASTM C1155
  • Stores up to 2 million data points
  • Rechargeable battery
  • Battery lifetime >1 month
  • High sensitive thermal detectors
  • Free readout software supplied with each kit
  • Compact design
  • USB interface

U-value is used to show the amount of heat loss in a building element such as a wall, floor or roof. It is also referred to as an ‘overall heat transfer co-efficient’ and provides a measure of how well parts of a building transfer heat. A high U-value indicates a poor thermal performance of the building envelope, whilst a low U-value indicates a high level of insulation. They are used as a way of predicting the composite behaviour of an entire building element rather than relying on the properties of individual materials.

Specifications

gSKIN Kit 2615C
Heat Flux Sensor XO677C, (size 30 x 30mm)
Heat Flux Range (W/m²) ±300
Resolutions (W/m²) <0.11
Temperature Accuracy (°C) ±0.5 (-10 to +65 °C)
±2.0 (-55…+125 °C)
Data Capacity 2 million readings
Operating Temperature Range -50 to +80°C (-25 to +65°C for data logger)
Calibrated Temperature Range -30 to +70°C

Each kit is supplied with a logger, heat flux sensor, 2 temperature sensors (1m & 5m cables), mounting tape and necessary software.

 

Product

Ref

Price

Product Description

GSKIN U-Value and Heat Flux Measurement Kit

GSKINKIT-2615C

£1,816.05

gSKIN U-Value Kit for measurement of u-value, heat flux and 2 temperature readings. Range ±300W/m² with a resolution of 0.22W/m². Sensor size 30mm x 30mm. Data logger has a logging frequency of 50Hz to every 12 hours and storage for up to 2 million readings. Kit consists of MSR Logger, DLOG-4231; Sensor, GSKIN-X0677C; 2 external temperature probes (1m & 5m cables); carry case; and Mounting tape (MOUNT-1235). Data logger is configured for the calibration settings of the supplied probes.
MORE INFO
Add to basket
MOUNT-1212. Thermally Conductive Mounting Paste

MOUNT-1212

£33.54

3.5g Tube of Thermally Conductive and Electrically Insulating Thermal Paste. Operating temperature range -50 to +130°C, thermal conductivity 9.0W/(mK). Ideal for applications where pressure is applied to fix the sensor and will provide a very strong thermal coupling as paste will adapt to the surface inhomogeneities.
MORE INFO
Add to basket

MOUNT-1213

£43.48

Thermally conductive and electrically insulating thermal glue. 2 x 3.5g tubes, operating temperature range -40 to +150°C, thermal conductivity 7.5W/(mK). Ideal for applications requiring additional mechanical stability.
MORE INFO
Add to basket

MOUNT-1235

£50.93

Double Sided Thermal Tape. Thermally conductive and electrically insulating double-sided tape. Dimensions: 3cm wide, 5m length. Ideal for mounting gSkin U-Value and Heat Flux sensors indoors.
MORE INFO
Add to basket
Thermal Conductive Putty. MOUNT-1237

MOUNT-1237

£21.12

250g tub of thermally conductive putty for mounting gSkin sensors. Ideal for repeated mounting and remounting sensors to different locations and surfaces. Suitable for use with various different U-Value and Heat Flux sensors.
MORE INFO
Add to basket

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2025 | Design. Build. Host.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Call us on +44 (0)1382 443000

Enquire now