Skip to content

omni instruments | sensors and data acquisition equipment

Sales & Technical Support

  • +44 (0) 1382 443000
  • info@omni.uk.com
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Products
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
  • Home
  • Custom Systems
  • System Hires
  • About
  • Contact
Need Help?
£0.00 0 Basket
Product
Edit Content
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
  • Data Loggers
  • Displacement
  • Display & Control
  • Flow Meters
  • Gas Detection
  • Gyros & Accelerometers
  • Level & Distance
  • Load Cells
  • Pressure Sensors
  • Radio & GSM Telemetry
  • Remote Monitoring
  • Serial Ethernet & ModBus
  • Solar & Wind Power
  • Subsea & Offshore
  • Temperature and Humidity
  • Test & Calibration
  • Torque Transducers
  • Vibration Monitoring
  • Voltage & Current
  • Water Quality
  • Weather Instruments
  • Accessories
£0.00 0 Basket
Home / Flow Meters / DPT-FLOW-5000-AZ-D
DPT-FLOW-5000-AZ-D

DPT-FLOW-5000-AZ-D

DPT-Flow-5000-AZ-D – Air Flow and Velocity Transmitter. Designed for Building Management Automation Systems with measurements for Volume Flow, Velocity and Static and Differential Pressures. Power Supply: 24V ±10% @ <1W. Measuring Range: 0 – 5000 Pascals. Accuracy: >125 Pa, ±1%, ±1 Pa and <125 Pa, ±1%, ±2 Pa. Selectable Output: 0-10V or 4-20mA options for Flow or Pressure Readings. Operating Temperature: -5 to +50°C. Backlit Dot Matrix Display. Auto-Zeroing every 10 minutes. IP54 Enclosures with M16 Glands. Dimensions: 90 x 95 x 36mm, Weight 150g.

£149.18

Need help finding the right product?

CONTACT US

Downloads

Datasheet

Differential Flow Transmitters - DPT-FLOW

  • Description

Description

DPT-Flow air flow transmitters are designed for building automation systems. These technologically advanced transmitters can measure volume flow, velocity, and static and differential pressure.

The transmitters can be connected directly to the pressure measurement points of a centrifugal fan, providing accurate flow measurement. The user interface enables easy selection of settings according to the selected fan or measurement probe.

The -AZ models include an automatic zeroing function, which zeroes the pressure measurement every 10 minutes. With automatic zeroing, the transmitter zero point is kept accurate by automatically eliminating the possible zero point drifting. The function also helps the device maintenance by removing the need of periodical manual zeroing by a service person.

Specifications

Power Supply: 24VDC/VAC (22…26V)
Power Consumption: < 1VA
Pressure Measurement: 0-5000Pa
Accuracy (25°C): Pressure < 125 Pa = ±1.5% plus ±2 Pa
Pressure > 125 Pa = ±1.5% plus ±1 Pa
Zero Point Calibration: Automatic Zeroing. Zeroes the pressure measurement every 10 minutes to eliminate any zero point drift.
Suitable media: Dry air and non-aggressive gases
Output signals: 0-10/2-10vDC, > 1kΩ
4-20mA, Load 20…500Ω
Temperature Range: -5 to +50°C
Materials  Housing: ABS and PC Plastic
Cable Gland: M16
Dimensions: 90 x 75 x 36 mm
Protection: IP54

links

  • About
  • Contact
  • Custom Systems
  • Privacy & Cookies
  • Terms & Conditions

omni instruments

Omni Instruments Ltd,
Unit 1, 14 Nobel Road,
Wester Gourdie Industrial Estate,
Dundee, DD2 4UH, UK

Sales & Support

  • +44 (0) 1382 443000
  • info@omni.uk.com

Payments

mastercard-color
visa-color
amex-color
Copyright Omni Instruments 2025 | Design. Build. Host.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Call us on +44 (0)1382 443000

Enquire now