AP-2000 Optical Electrodes

Aquaprobe optical water quality sensors for the AP-2000 digital water quality sensor. These advanced optical electrodes are incredibly practical, allowing for easy, tool-free removal and replacement in the field. They’re designed specifically for seamless integration with the AP-2000 sensor, to provide a additional parameters to your water quality monitor sensor. The AP-2000 Optical Electrodes offer measurements of Turbidity, Chlorophyll A, Blue Green Algae (fresh and salt water options), Rhodamine, Fluoresceine, CDOM/FDOM and refined oil.

Need help finding the right product?

Description

The AP-2000 water quality probe is a multi-parameter sensor and comes pre-fitted with probes covering pH, ORP, Conductivity, TDS, SSG, Resistivity, Salinity, Dissolved Oxygen and Temperature probes, the AP-2000-D add a depth sensor. Each probe comes with two empty sockets to add an Optical, or Ion Selective Electrode (ISE) sensors. This page covers the 8 Optical Electrodes that can be fitted to Aux Port 1 on the AP-2000 probes to add one more parameter to the probe. Additional parameters covered are: Turbidity; Chlorophyll; Blue Green Algae; Rhodamine; Fluorescein; Refined Oil; or CDOM/FDOM.

The table below covers the available parameters, with links to get more details on the parameter for each probe.

Optical Electrode Options

Turbidity Range 0 – 4000 NTU
Resolution 2 Auto-range scales: 0.0 99.9 NTU, 100 – 4000 NTU
Accuracy ±5% of reading
Chlorophyll Range 0 – 500 µg/L (ppb)
Resolution 2 Auto-range scales: 0.0 99.99 µg/L, 100. – 500.0 µg/L
Repeatability ±5% of reading
Phycocyanin (Freshwater Blue-Green Algae)
Range 0 – 300,000 cells/mL
Resolution 1 cell/mL
Repeatability ±10% of reading
Phycoerythrin (Marine Blue-Green Algae) Range 0 – 200,000 cells/mL
Resolution 1 cell/mL
Repeatability ±10% of reading
Rhodamine WT Dye Range 0 – 500 µg/L (ppb)
Resolution 2 Auto-range scales: 0.0 99.99 µg/L, 100. – 500.0 µg/L
Repeatability ±5% of reading
Fluorescein Dye Range 0 – 500 µg/L (ppb)
Resolution 2 Auto-range scales: 0.0 99.99 µg/L, 100. – 500.0 µg/L
Repeatability ±5% of reading
Refined Oil Range 0 – 10,000 µg/L (ppb)
Resolution 0.1 µg/L
Repeatability ±10% of reading
CDOM/FDOM Range 0 – 20,000µg/L (ppb) (Quinine Sulphate)
Resolution 2 Auto-range scales: 0.0 – 9,999.9µg/L, 10,000 – 20,0000µg/L
Repeatability ±10% of reading

Fluorescence measurement techniques are not ideal for quantitative measurement and it is therefore impossible to specify an absolute accuracy. The accuracy figures quoted above represent the equipment’s capability at the calibration points at 25°C. In order to obtain accurate results, data obtained with a fluorescent electrode in the field must be post-calibrated with data from standard laboratory analysis of grab samples acquired during the study.

The AP-2000 Aux Ports

The AP-2000 probe has two available Aux ports. Aux Port 1 can be fitted with either an Optical or ISE sensor. This port can be fitted with any one of the 8 AP-2000. Aux Port 2 can only be used with the Ion Selective Electrode, which can be found on this link (to be added shortly).

Product

Ref

Price

Product Description

2000-CPHYLL

£1,070.00

AP-2000 Chlorophyll Electrode with 2 Auto-Range scales 0-99.99 µg/L or 100-500 µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L.

2000-TURB

£490.00

AP-2000 Turbidity Electrode with 2 Auto-Range scales 0-99.9 Nephelometric Turbidity Units (NTU) or 100-4000 NTU. Accuracy ±5% of Auto-ranged Scale. Minimum Level of Detection 0.0 NTU, Minimum Level of Repeatibility 5.0 NTU.

2000-BGA-PC

£1,070.00

AP-2000 Phycocyanin Electrode. Designed for Blue Green Algae Monitoring in Fresh Water. Range 0-300.000 cells/mL. Minimum Level of Detection 200 cells/mL.

2000-BGA-PE

£1,070.00

AP-2000 Phycoerythrin Electrode. Designed for Blue Green Algae Monitoring in Marine Water. Range 0-200.000 cells/mL. Minimum Level of Detection 400 cells/mL.

2000-RHOD

£1,070.00

AP-2000 Rhodamine WT Dye Optical Electrode with 2 Auto-Range scales 0-99.99µg/L  or 100-500µg/L. Minimum Level of Detection 0.1 µg/L, Minimum Level of Repeatability 5.0 µg/L.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.