MiniWater 20 Mini vane anemometer. Flow velocity range 0.02-5m/s with accuracy ±2% of full scale, ±3% of reading. Sensing head 22mm diameter x 28mm, probe length 175mm. Sensor is supplied with 1.8m cable and connector for interfacing with MC20 and MC 4.0 Displays with Lemo Connectors. Plastic sensing head with metal blade turbine suitable for open channel water flows. Operating range up to 70°C. MIWA2021

£759.89

Need help finding the right product?

Description

The MIWA2021 is a turbine flow sensor that connects to the MC20 handheld display to provide flow readings for surface water flows in rivers, canals, or any other open channel water courses. The probe head is a synthetic plastic construction with a metal turbine that generates a frequency output each time one of the four turbine blades pass the probe handle. The frequency of rotation is proportional to the flow velocity. The MC20 converts the rotational frequency into a standard signal and shows the measured value in the display.

The MIWA2021 includes the Mini snaphead, which is only 22mm in diameter, has a flow range of 0-5m/s. This head is slightly larger than the probe handle, but may still be inserted into pipework using a compression gland and only requires a minimum access diameter of 35mm. The Mini head is ideal for measuring flow rates in rivers, lakes and channels.

Specifications

Air Probe: MiniWater 6 Mini
Range: 0.02 – 5 m/s
Accuracy: ±2.0% full scale
±3.5% reading
Operating Temp: Up to +70°C
Head Dimensions: ø 22 x 28 mm
Access Opening: 35mm
Snaphead Material: Synthetic Plastic
Vane Material: Aluminium
Probe Length: 175mm
Cable Length: 1.8m Cable

Cleaning Instructions – MiniWater 20 Mini Plastic Probe

As the probes are highly sensitive measuring instruments, they must be cleaned with very great care.

Any fibres, weeds or other foreign bodies should be carefully removed with fine tweezers. When doing so, take care not to bend or otherwise damage the vanes or the spindle.

The adjustment of the bearing screws must never be changed. This can result in erroneous measurements.

Never allow hard objects to contact rotating impellers!!!

Cleaning agents which extract the plasticizer from the plastic are never to be used for plastic probes (practically all solvents!).

We recommend the following for cleaning the probes:

– clean running water
– soapy water
– pure benzine

Cleaning example:

1) Carefully swish the top part of the impeller back and forth in clean, pure benzine for about 10 min. Then swish the top part of the impeller back and forth in clean kerosene for about. 1 min. to re-lubricate the impeller bearings.

If soapy water is used as a cleaning agent it is advisable to wash out the soap solution thoroughly with distilled water before lubrication with kerosene.

2) After cleaning the probe, rub it dry externally with a clean, dry, fluff-free cloth.

3) Leave the top part of the impeller to dry for about 30 minutes.

Only clean the head of the impeller! Probes are on no account to be fully immersed in the solution.

Snap-Head Replacement

Snap Head Principle

The snap-head fixing system renders it very simple to fit a new impeller to the flow probe: this saves costly non-productive time and in the event of damage to the snap-head enables you to have the probe back in service in a matter of seconds by simply changing the snap-head.

Every MiniWater probes generate a pulse each time a vane blade passes the probe handle and the MC20 converts the output to a flow velocity to display on the MC20. Each snap head is automatically detected by the MC20 display and in different probes can be selected in the main menu. Selecting the incorrect probe will not match the internal calculations in the MC20 and will lead to inaccurate readings on the display.

 

MIWA2021 is the replacement part for part no. 95.0012.

400.0203

£870.49

MC 4.0 Multiprobe Anemometer with Touchscreen, 4.000mAh Lithium Polymer Battery & Lemo Connector. The MC 4.0 is the base unit and can be used for determining the flow velocity, temperature and relative humidity of gaseous and liquid media with the relevant measurement probes. 3.2″ TFT Touchscreen Display, 2Hz measurement rate, internal logger for up to 1 million readings and bluetooth connectivity. Dimensions: 168 x 68 x 38mm, Weight 300g, IP67 with a removeable blue rubber case. Operating Temperature 0 to 60°C, 0-99%RH. Compatible with any MiniAir 20 and MiniWater 20 Probes.

95.0026

£213.57

MiniWater Mini Replacement Snaphead. Flow velocity range 0-5m/s. Sensing head 22mm diameter x 28mm. Suitable for use with the following MiniWater probe part numbers: MIWA2021; MIWA0621; MIWA6021; MIWA6421; 95.0012; 95.0295; 95.0303; 95.0355.

98.0030

£51.49

Aluminium extension rod for the MiniAir/Water range of vane/turbine probes. Diameter 15mm and 180mm long extension rod. Rod includes M12 male and female threads for connecting to all MiniAir, MiniWater and ThermoAir probes.

98.0016

£82.00

Aluminium extension rod for the MiniAir/Water range of vane/turbine probes. Diameter 15mm and 300mm long extension rod. Rod includes M12 male and female threads for connecting to all MiniAir, MiniWater and ThermoAir probes.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.

Enquire now