- 0 to 5A AC RMS range ideal for accurately measuring a typical current transformer
- 0 to 300vAC RMS range allows accurate supply voltage monitoring
- The 4179 measures standard input ranges and can be freely configured to customer defined input range.
- Can convert narrow AC current/voltage inputs to wide bipolar or unipolar outputs.
- Configurable input limits control the output value for increased safety
Features
-
- The latest analog and digital techniques used to obtain the maximum accuracy and immunity to interference.
- Possibility of output safety feedback by selecting S 4-20 mA output.
- The current output can drive up to 800 Ohms, with an adjustable response time of 0-60.0 seconds.
- Exceptional mA output load stability of <0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
- Each unit is tested to a high 2.3 kVAC, 3-port galvanic isolation level.
Excellent signal to noise ratio of > 60 dB.
- Output: Active unipolar or bipolar ±20mA, 2-wire 0-20mA, bipolar ±10V with direct or inverted action
- Universal AC or DC supply
- Programmable by way of detachable 4501 display front
- Modbus RTU output via 4511 deteachable display
4501 Display / programming front
Application:
- Communications interface for modification of operational parameters in 4179.
- Can be moved from one 4179 module to another and download the configuration of the first converter to subsequent converters.
- Fixed display for readout of process data and status
Technical characteristics:
- LCD display with 4 lines; line 1 (H = 5.57 mm) shows input signal, line 2 (H = 3.33 mm) shows units. Line 3 alternates between digital output value and scaling (kHz, Hz, mHz, P/m, P/h, P/d) or shows TAG no. Line 4 shows tendency readout for the input signal and communication status.
- Programming access can be blocked by assigning a password. The password is saved in the converter in order to ensure a high degree of protection against unauthorised modifications to the configuration.
4511 Modbus Communications Interface
Application:
- The 4511 detachable display adds Modbus RTU RS485 serial communications to all current and future 4000/9000 series units
- All individual unit operating parameters can easily and quickly be configured by using the Modbus communication or by using the front display menu
- The 4511 display can be used to read the process signal, simulate the output signal, indicate sensor errors and interna device errors
Technical characteristics:
- 4511 has full 4501 functionality for programming and display
- RS485 Modbus RTU protocol
- Multi-drop half-duplex connection via shielded RJ45 connector on top of module
- Modbus parameters such as address, baud rate, stop bit(s) and parity bits are configured from, and stored on, the 4511 interface
- 2.5kVAC galvanic isolation between serial wiring and 4000/9000 units
If required, Omni Instruments will program a 4179, 4501 or 4511 to your specific requirements. Please contact us for details.