Replacement MX6 Sensor for Hydrogen (H2). Range 0 to 2,000ppm, Resolution 1ppm. Response time 40 seconds (t50)

£642.00

Need help finding the right product?

Description

Hydrogen (H2) is the lightest and most abundant chemical element in the universe. On Earth, it almost always exists in compounds (H2O, or hydrocarbons), but it can be produced and used as a gas in various industrial settings. It is a colourless, odourless, and tasteless gas.

Key Properties:

  • Colourless, Odourless, Tasteless: Undetectable by human senses.
  • Extremely Flammable/Explosive: This is its most significant hazard. It has a very wide flammability range in air (4% to 75% by volume) and a very low ignition energy, meaning it can easily ignite and cause explosions.
  • Non-toxic (Asphyxiant): Hydrogen itself is not toxic. However, in high concentrations, it acts as a simple asphyxiant, displacing oxygen in an enclosed space and potentially leading to suffocation.
  • Very Light: It is significantly lighter than air, so it dissipates very rapidly outdoors or in well-ventilated areas, but can accumulate in unventilated high points within enclosed spaces.
  • Cryogenic Liquid: When cooled to extremely low temperatures (below -253 °C or -423 °F), it becomes a liquid (liquid hydrogen, LH2), which is used for energy storage and rocket fuel.

 

Replacement Sensor, Part No. 17124975-C, Properties

Gas Detected
(Abbreviation)
Sensor Type Measurement Response time
(Seconds)
Calibration Gas
& Concentration
Range Resolution T50 T90
Hydrogen
(H2)
Electrochemical 0 to 2,000ppm 1.0 ppm 40 90 H2
100 ppm

 

Toxic Gas Sensor Cross-sensitivity Table

Target Gas Sensor
CO CO
(H2 Low)
H2S SO2 NO2 Cl2 ClO2 HCN HCl PH3 NO H2 NH3
CO 100 100 1 1 0 0 0 0 0 0 0 20 0
H2S 5 5 100 1 -40 -3 -25 10 300 25 10 20 25
SO2 0 5 5 100 0 0 0 40 0 0 -40
NO2 -5 5 -25 -165 100 45 -70 30 0 -10
Cl2 -10 0 -20 -25 10 100 60 -20 6 -20 0 0 -50
ClO2 20 100
HCN 15 50 1 0 0 100 35 1 0 30 5
HCl 3 5 0 2 0 0 100 0 15 0 0
PH3 -100 425 300 100
NO 25 40 -0.2 1 5 -5 100 30 0
H2 22 3 0.08 0.5 0 0 0 0 0 0 0 100 0
NH3 0 0 0 0 0 0 0 0 0 0 0 0 100

The table above reflects the percentage response provided by the sensor (top row) when exposed to a known concentration of the target gas (column 1).
The numbers were measured under these environmental conditions: 20 °C (68 °F), 50% RH and 1 atm.
The specified cross-interference numbers apply to new sensors only and may vary with time as well as from sensor to sensor.
“-” means no data available.
This table is given as a reference only and is subject to change.

 