17124975-B

Replacement MX6 Sensor for Hydrogen Cyanide (HCN). Range 0 to 30ppm, Resolution 0.1ppm. Response time 25 seconds (T50)

£642.00

Need help finding the right product?

Description

Hydrogen Cyanide (HCN) is a highly volatile, colourless liquid below 26°C (79°F), and a colourless gas above that temperature. It has a distinctive bitter almond odour, though not everyone can detect this smell, and its presence can also cause olfactory fatigue (loss of smell) at higher concentrations. It is one of the most rapidly acting and deadly poisons known.

Key Properties:

  • Colourless: Invisible as a gas or liquid.
  • Odour: Distinctive bitter almond smell. Crucially, about 20-40% of the population cannot detect this odour due to a genetic trait, and exposure to higher concentrations can rapidly cause olfactory fatigue, making the odour an unreliable warning sign.
  • Extremely Toxic: Acts as a chemical asphyxiant by interfering with the body’s ability to use oxygen at the cellular level, leading to rapid cellular death. Exposure can be fatal within minutes.
  • Flammable/Explosive: HCN gas is highly flammable and can form explosive mixtures with air.
  • Density: Slightly lighter than air as a gas, but it disperses readily. It can also form heavier-than-air mixtures with water vapor.
  • Volatility: Evaporates very quickly at room temperature.

 

Replacement Sensor, Part No. 17124975-B, Properties

Gas Detected
(Abbreviation)
Sensor Type Measurement Response time
(Seconds)
Calibration Gas
& Concentration
Range Resolution T50 T90
Hydrogen Cyanide
(HCN)
Electrochemical 0 to 30 ppm 0.1ppm 25 80 HCN
10 ppm

 

Toxic Gas Sensor Cross-sensitivity Table

Target Gas Sensor
CO CO
(H2 Low)
H2S SO2 NO2 Cl2 ClO2 HCN HCl PH3 NO H2 NH3
CO 100 100 1 1 0 0 0 0 0 0 0 20 0
H2S 5 5 100 1 -40 -3 -25 10 300 25 10 20 25
SO2 0 5 5 100 0 0 0 40 0 0 -40
NO2 -5 5 -25 -165 100 45 -70 30 0 -10
Cl2 -10 0 -20 -25 10 100 60 -20 6 -20 0 0 -50
ClO2 20 100
HCN 15 50 1 0 0 100 35 1 0 30 5
HCl 3 5 0 2 0 0 100 0 15 0 0
PH3 -100 425 300 100
NO 25 40 -0.2 1 5 -5 100 30 0
H2 22 3 0.08 0.5 0 0 0 0 0 0 0 100 0
NH3 0 0 0 0 0 0 0 0 0 0 0 0 100

The table above reflects the percentage response provided by the sensor (top row) when exposed to a known concentration of the target gas (column 1).
The numbers were measured under these environmental conditions: 20 °C (68 °F), 50% RH and 1 atm.
The specified cross-interference numbers apply to new sensors only and may vary with time as well as from sensor to sensor.
“-” means no data available.
This table is given as a reference only and is subject to change.

 

MX6 Replacement Sensor Cells

The MX6 gas detectors include field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration. Up to 5 sensor can be installed, each in one or more specific location.