omni instruments | sensors and data acquisition equipment

Sales & Technical Support

17124975-8

Replacement MX6 Sensor for Chlorine Dioxide (ClO2). Range 0 to 1ppm, Resolution 0.01ppm. Response Time 7 Seconds

£642.00

Need help finding the right product?

Description

Chlorine Dioxide (ClO2) is a synthetic, greenish-yellow to reddish-yellow gas with a sharp, irritating odour similar to chlorine or nitric acid. Unlike chlorine, ClO2 is not stored or shipped as a compressed gas due to its instability and explosive nature. Instead, it is almost always generated on-site, just before use, by reacting sodium chlorite with an oxidiser (like chlorine gas or sodium hypochlorite) or an acid.

Key Properties

  • Colour: Greenish-yellow to reddish-yellow.
  • Odour: Sharp, irritating, chlorine-like. Detectable at very low concentrations.
  • Toxicity: Highly toxic, causing severe irritation to the respiratory system, eyes, and skin.
  • Density: Heavier than air, so it tends to accumulate in low-lying areas and confined spaces.
  • Reactivity/Instability: Extremely reactive and can be explosive at high concentrations, especially when mixed with air, or under pressure, heat, or light. This is why it’s generated on-site.
  • Powerful Oxidiser: A very effective disinfectant and bleaching agent.

 

Replacement Sensor, Part No. 17124975-8, Properties

Gas Detected
(Abbreviation)
Type Measurement Response time
(Seconds)
Calibration Gas
& Concentration
Range Resolution T50 T90
Chlorine Dioxide
(ClO2)
Electrochemical 0 to 1 ppm 0.01 ppm 7 60 ClO2
1 ppm

 

Toxic Gas Sensor Cross-sensitivity Table

Target Gas Sensor
CO CO
(H2 Low)
H2S SO2 NO2 Cl2 ClO2 HCN HCl PH3 NO H2 NH3
CO 100 100 1 1 0 0 0 0 0 0 0 20 0
H2S 5 5 100 1 -40 -3 -25 10 300 25 10 20 25
SO2 0 5 5 100 0 0 0 40 0 0 -40
NO2 -5 5 -25 -165 100 45 -70 30 0 -10
Cl2 -10 0 -20 -25 10 100 60 -20 6 -20 0 0 -50
ClO2 20 100
HCN 15 50 1 0 0 100 35 1 0 30 5
HCl 3 5 0 2 0 0 100 0 15 0 0
PH3 -100 425 300 100
NO 25 40 -0.2 1 5 -5 100 30 0
H2 22 3 0.08 0.5 0 0 0 0 0 0 0 100 0
NH3 0 0 0 0 0 0 0 0 0 0 0 0 100

The table above reflects the percentage response provided by the sensor (top row) when exposed to a known concentration of the target gas (column 1).
The numbers were measured under these environmental conditions: 20 °C (68 °F), 50% RH and 1 atm.
The specified cross-interference numbers apply to new sensors only and may vary with time as well as from sensor to sensor.
“-” means no data available.
This table is given as a reference only and is subject to change.

 

MX6 Replacement Sensor Cells

The MX6 gas detectors include field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration. Up to 5 sensor can be installed, each in one or more specific location.

We are here to help

Need help with your products or have a question for us on our custom systems? Use the form below to send us a message and our experts will be in touch to help.