Description
Features
- Low Voltage Power Communications Interface for WindObserver IS
- Fibox Euronord Polyester Enclosure
- For Use in Non-Hazardous Areas with US Conection to Hazardous Area
- ATEX, IECEx & UKEX certification
- 9-30vDC Power Supply.
- Galvanic Isolation Between Input Power and Anemometer Supply
Specifications
Digital Output
Communication:
|
RS422, Full Duplex, WindObserver IS to PCI or LVPCI RS232 and RS422 (Data from PCI or LVPCI) System Data Lines Opto Isolated and Protected with Zener Barriers |
Baud Rates: | 1200, 2400, 4800, 9600, 19200. |
Formats: | 8 bit data; odd, even or no parity |
Anemometer Status: | Supplied as Part of Standard Gill Message (NMEA Output Includes V and A Codes as Part of the Message |
Power Option
Option: | DC Supply (LVPCI) |
Input Power: | 9 to 30vDC @ 200mA Max |
Galvanic Isolation: | Between Input Power and WindObserver IS |
Anemometer Supply: | 6-12vDC, 30mA Peak (from PCI or LVPCI All Circuits Protected to 0.8 Joules |
PSU Enclosure: | Fibox Euronord Polyester |
Dimensions: | 260 x 160 x 93mm |
Weight: | 2.4Kg |
IP Rating: | IP54 |
Operating Conditions: | -30 to +60°C, 5-95%RH |
EMC: | EN 61326-2-1:2013, EN 61204-3:2000, EN 60945:2002 clause 9 and 10 |
Approvals: | ATEX, IECEX & UKEX Certification |