LogBox Data Logger
  • LogBox Data Logger

Novus LogBox Dual Channel Data Logger

Quick Overview

LogBox data loggers are available with two analogue or a single analogue and digital counter input. Ideal for applications such as flow monitoring, with there robust design and waterproof casing for easy installation. Downloading and configuration is via an infrared interface allow for PC, Laptop or PDA configuration options.
View Options

Details

Features

  • Channel 1: Counter input - NPN, PNP, Pulse or Dry Contact
  • Max. frequency: 4000 Hz (NPN or PNP) or 20 Hz (dry contact)
  • Maximum counting: 65,535 per period.
  • Channel 2: 0-20mA, 4-20mA, 0-50mV and 0-10Vdc
  • Memory capacity: 32k or 64k readings
  • Interval between readings: 1 second to 18 hours
  • External battery switch time: 0 to 10 s
  • Power: Internal 3.6V lithium battery (1/2 AA)
  • Estimated autonomy: Over 2000 days (one daily download)
  • Memory retention 10 years without power
  • Working temperature: From –40°C to 70°C.
  • Protection: IP65, IP67 and IP68 models (see lateral label on product)
  • Material: ABC + PC case, Polycarbonate film
  • Dimensions: 60x70x35mm 
     

LogBox-DA is an electronic data logger with two input channels, one analogue and one digital. Input data is stored in the logger internal memory, for later download to a PC for visualization and analysis in the form of tables or graphs. The data is easily exported to spreadsheets.

The LogChart-II is the software used to configure the logger, download and visualize data. The logger configuration allows defining the logger operation mode, including programming the start/stop time of data acquisition. Other parameters such as signal input type, logging interval, multiplication factor, scale range, etc, are easily selected through the LogChart-II software.

The LogBox-DA also provides a signal for commanding an external power supply (battery) of a device connected to the logger. This feature allows that external devices, such as a transmitter, be powered only during the measurement sample time, thus extending the autonomy of these external batteries.

LogBox-AA replaces the digital channel with a second analogue channel that can also accept the below temperature sensors.

  • J range: -50 to 760 °C (-58 to 1400ºF)
  • K range: -90 to 1370 °C (-130 to 2498ºF)
  • T range: -100 to 400 °C (-148 to 752ºF)
  • N range: -90 to 1300 °C (-130 to 2372ºF)
  • R range: 0 to 1760 °C (32 to 3200ºF)
  • S range: 0 to 1760 °C (32 to 3200ºF)
  • B range: 150 to 1820 °C (32 to 3308ºF)
  • Pt100 range: -200.0 to 650.0 °C (-328 to 1202ºF) 

Use our online calculator to work out input signal ranges and scaling in engineering units for data loggers. Also calculates shunt resistor values, resolution and null point offsets.

Availability: Stock Item

 

Components / Downloads

For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.

REF DESCRIPTION DOWNLOADS PRICE ORDER ITEM
 
LOGBOX-DA Data Logger
8813001001
8813001001
LogBox-DA IP65 Data Logger, 1 Analogue (0-50mV 0-10v and 4-20mA inputs) & 1 Digital input for pulse inputs (NPN or PNP up to 4 KHz) or dry contact (up to 20 Hz), with 64,000 reading memory, battery life up to 3 years. Sensor external power switch. External connection via IP65 compression glands.
View FileManual
   Size: (2.21 MB)
View FileDatasheet
   Size: (216.68 KB)
£124.07
or call us for a quote
 
LOGBOX-AA Data Logger
8813002001
8813002001
LogBox-AA IP65 Data Logger, 2 Analogue Channels for PT100, Thermocouples (types J, K, T, E, N, R, S or B), Voltage (0 to 50mV or 0 to 10V), or Current (0 to 20mA or 4 to 20mA). with 64,000 reading memory, battery life up to 3 years. Sensor external power switch. External connection via IP65 compression glands.
View FileManual
   Size: (795.02 KB)
View FileDatasheet
   Size: (1018.93 KB)
£130.85
or call us for a quote
 
Software and Download Cable
8813099050
8813099050
IrLINK-3-USB Infrared Interface for USB and LogChart Software
£38.65
or call us for a quote
 
Weatherproof Enclosure for LogBox and Battery
ENCL-WMT-EXSML-BATT
ENCL-WMT-EXSML-BATT
Small weatherproof ABS enclosure fitted with a 1.2AH 12V lead acid battery and cable gland for external sensors. Sensor wired to relevant data logger as required.
£92.85
or call us for a quote